USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region
Schneider Eletric TSXPAY282 Picture
Discontinued

Schneider Eletric TSXPAY282 Picture
Discontinued

Preventa safety module - 24 V DC - standard format - < 5 W

Show more characteristics >
TSXPAY282  has not been replaced. Please contact your customer care center for more information.
  • Price
    1,047.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon Premium Automation platform
    product or component type
    Preventa safety module
    Complementary
    [Us] rated supply voltage
    24 V DC
    supply voltage limits
    19.2...30 V
    activation threshold
    < 20 V
    short-circuit protection
    1 A gG external conforming to IEC 947-5-1 for F1 on power supply
    4 A gG external conforming to IEC 947-5-1 for F2 on safety relay outputs
    isolation voltage
    4000 V III 2
    discrete input number
    1 double or single contact selection input conforming to IEC 1131 Type 1
    1 feedback loop input conforming to IEC 1131 Type 1
    1 reset PB input conforming to IEC 1131 Type 1
    1 reset PB monitoring input conforming to IEC 1131 Type 1
    12 emergency stop or limit switch discrete inputs conforming to IEC 1131 Type 1
    discrete input logic
    Positive
    inrush current
    <= 0.5 A
    isolation between input and earth
    500 Vrms 50/60 Hz for 60 s
    power dissipation in W
    < 5 W
    safety outputs
    4 NO safety relay AGCDO gold plated volt free output
    System Voltage
    17...127 V DC relay output
    19...250 V AC relay output
    rated power in VA
    120 VA 48 V AC-15 inductive
    280 VA 110 V AC-15 inductive
    550 VA 220 V AC-15 inductive
    60 VA 24 V AC-15 inductive
    rated power in W
    60 W 24 V DC-13 inductive 100 ms
    [Ithe] conventional enclosed thermal current
    <= 2.5 A
    minimum output current
    >= 30 mA
    response time on output
    < 12 ms
    isolation between output and earth
    300 V conforming to DIN VDE 0110 part 2
    1500 Vrms 50/60 Hz for 60 s
    safety acquisition
    Monitor external power supply of the module
    Read enable inputs
    Read feedback loop
    Read the safety outputs control
    Read status of the 24 inputs
    local signalling
    28 LEDs diagnostic of safety system
    electrical connection
    1 connector removable screw terminal block 6 pins
    1 connector SUB-D 44 pins for connecting the safety system
    cable cross section
    0 in² (1.5 mm²) with cable end safety output circuit
    0...0 in² (0.2...2.5 mm²) without cable end safety output circuit
    current consumption
    < 150 mA 5 V DC
    <= 200 mA 24 V DC
    module format
    Standard
    product weight
    1.08 lb(US) (0.49 kg)
    Environment
    ambient air temperature for operation
    32...104 °F (0...40 °C) without fan
    32...140 °F (0...60 °C) with fan module
    ambient air temperature for storage
    -13...158 °F (-25...70 °C)
    IP degree of protection
    IP20 conforming to IEC 60529
    standards
    CSA C22.2 specific requirements (PLC)
    EN 954 machine safety parts of control systems
    EN/IEC 60204-1 machine electrical equipment
    EN/IEC 61131-2 specific requirements (PLC)
    EN/ISO 12100 machine electrical equipment
    ISO 13850 emergency stop equipment
    UL 508 specific requirements (PLC)
    ISO 13849-1 category 4 machine safety parts of control systems
    IEC 61508 SIL 3 machine safety parts of control systems
    product certifications
    BG
    CSA
    UL
    Ordering and shipping details
    Category
    22558 - TSX PREMIUM, ATRIUM & PL7 PRO
    Discount Schedule
    PC22
    GTIN
    00785901530442
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    2.21
    Returnability
    N
    Country of origin
    FR
    Offer Sustainability
    RoHS (date code: YYWW)
    REACh
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 12/6/18
    Size 195.3 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 12/6/18
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Standard and Extendable Racks for Modules Mounting
    Dimensions of Modules and Racks


    (1) With screw terminal block modules.

    (2) Maximum depth for all types of modules and their associated connectors.


  • Connections and Schema

    The Safety System


    Connection of Emergency Stop Buttons and Safety Switches
    Double Contacts (recommended)

    Double contact wiring of inputs is suitable for applications requiring category 3 or 4 compliant levels of safety.

    Short circuits between channels are detected.

    ES PB or PS short circuits are detected and pinpointed.


    NOTE: If less than 12 double contacts are being used, the input terminals that are not in use must be bridged.

    Single Contact

    This wiring is not suitable for applications requiring category 3 or 4 compliant levels of safety.

    Not all errors are detected, nor are ES PB or PS short circuits. Here, pressing this PB will not cause the safety circuits to open (loss of the safety function).


    NOTE: If less than 12 contacts are being used, the input terminals that are not in use must be bridged.


    Safety Output Wiring Diagrams
    Feedback Loop Connection

    The category 4 immediate stop system design requires supply shut-off device redundancy and activation monitoring.

    Wiring of open contacts (K3, K4) or (K3, K4, K5, K6) allows every activation request to be checked.

    It is compulsory for the contacts of relays (K3, K4) or (K3, K4, K5, K6) to be mechanically linked.

    Category 3 wiring means:

    • no wiring of auxiliary contacts in the feedback loop (a strap links terminals Y1 and Y2/S33),

    • standard switches, with non-guided contacts, are sufficient.

    2-switch set-up (category 4):


    4-switch set-up (category 4):



    Connection of the Safety System Reactivation Function
    Wiring Diagram for Automatic Reactivation


    Wiring Diagrams for Manual Reactivation

    With Reactivation button monitoring (recommended):


    Without Reactivation button monitoring:



    Safety Outputs
    Wiring Diagram


    13/23, 33/43:
    Independent supply inputs
    14, 24, 34, 44:
    Safety outputs

    NOTE:

    Wires cross-section:

    • with termination: 2 x 1 mm2/16 AWG or 1 x 1.5 mm2/14 AWG

    • without termination: 1 x 2.5 mm2/12 AWG