USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

module TM3 - 8 IO relays

Show more characteristics >
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price*
    109.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon TM3
    product or component type
    Discrete I/O module
    range compatibility
    Modicon M221
    Modicon M241
    Modicon M251
    discrete input number
    4 input conforming to IEC 61131-2 Type 1
    discrete input logic
    Sink or source (positive/negative)
    discrete input voltage
    24 V
    discrete input current
    7 mA input
    discrete output type
    Relay normally open
    discrete output number
    4
    discrete output logic
    Positive or negative
    discrete output voltage
    24 V DC relay output
    240 V AC relay output
    discrete output current
    2000 mA relay output
    Complementary
    discrete I/O number
    8
    current consumption
    5 mAat 5 V DC via bus connector at state off
    0 mA at 24 V DC via bus connector at state on
    0 mAat 24 V DC via bus connector at state off
    25 mAat 5 V DC via bus connector at state on
    discrete input voltage type
    DC
    voltage state 1 guaranteed
    15...28.8 V input
    current state 1 guaranteed
    >= 2.5 mA for input
    voltage state 0 guaranteed
    0...5 V input
    current state 0 guaranteed
    <= 1 mA for input
    input impedance
    3.4 kOhm
    response time
    4 ms turn-on
    4 ms turn-off
    current per output common
    7 A
    mechanical durability
    20000000 cycles
    minimum load
    10 mA at 5 V DC relay output
    local signalling
    1 LED per channel green I/O state
    electrical connection
    Removable screw terminal block pitch 5.08 mm with 11 terminal(s) of 2.5 mm² connection capacity for inputs and outputs
    insulation
    Non-insulated between inputs
    500 V AC between output and internal logic
    Non-insulated between outputs
    500 V AC between input and internal logic
    1500 V AC between input groups and output groups
    750 V AC between open contact
    marking
    CE
    mounting support
    Top hat type TH35-15 rail conforming to IEC 60715
    Top hat type TH35-7.5 rail conforming to IEC 60715
    Plate or panel with fixing kit
    height
    3.54 in (90 mm)
    depth
    3.33 in (84.6 mm)
    width
    1.08 in (27.4 mm)
    product weight
    2.09 lb(US) (0.95 kg)
    Environment
    standards
    EN/IEC 61131-2
    EN/IEC 61010-2-201
    product certifications
    C-Tick
    cULus
    resistance to electrostatic discharge
    4 kV (on contact) conforming to EN/IEC 61000-4-2
    8 kV (in air) conforming to EN/IEC 61000-4-2
    resistance to electromagnetic fields
    9.14 V/yd (10 V/m) at 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
    2.74 V/yd (3 V/m) at 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
    0.91 V/yd (1 V/m) at 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
    resistance to magnetic fields
    30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
    resistance to fast transients
    2 kV relay output conforming to EN/IEC 61000-4-4
    1 kV I/O conforming to EN/IEC 61000-4-4
    surge withstand
    1 kV input in common mode conforming to EN/IEC 61000-4-5
    2 kV output in common mode conforming to EN/IEC 61000-4-5
    resistance to conducted disturbances
    10 Vrmsat 0.15...80 MHz conforming to EN/IEC 61000-4-6
    3 Vrmsat spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
    electromagnetic emission
    Radiated emissions, test level: 40 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 30...230 MHz) conforming to EN/IEC 55011
    Radiated emissions, test level: 47 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011
    ambient air temperature for operation
    14...131 °F (-10...55 °C) horizontal installation
    -10...35 °C vertical installation
    ambient air temperature for storage
    -13...158 °F (-25...70 °C)
    relative humidity
    10...95 % without condensation in operation
    10...95 % without condensation in storage
    IP degree of protection
    IP20 with protective cover in place
    pollution degree
    2
    operating altitude
    0...6561.68 ft (0...2000 m)
    storage altitude
    0...9842.52 ft (0...3000 m)
    vibration resistance
    3.5 mm (vibration frequency: 5...8.4 Hz) on DIN rail
    3 gn (vibration frequency: 8.4...150 Hz) on DIN rail
    3.5 mm (vibration frequency: 5...8.4 Hz) on panel
    3 gn (vibration frequency: 8.4...150 Hz) on panel
    shock resistance
    15 gn (test wave duration:11 ms)
    Ordering and shipping details
    Category
    22533 - M2XX PLC & ACCESSORIES
    Discount Schedule
    MSX
    GTIN
    00785901981657
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    0.48999999999999999
    Returnability
    Y
    Country of origin
    TW
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  1348  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    California proposition 65
    WARNING: This product can expose you to chemicals including:
    - - - - - - - Substance 1
    Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm.
    - - - - - - - More information
    For more information go to www.p65warnings.ca.gov
  • Documents and Downloads

    Language
    • English
    Catalog
    Date
    Size
    Add to My Documents
    Digest 178 Catalog 27: Automation Products (Version 1.0)
    User guide
    Date
    Size
    Add to My Documents
    Modicon M241 Logic Controller, Hardware Guide (Version 07)
    SoMachine, Programming Guide (Version 15)
    Date 1/2/18
    Size 15.8 MB
    Modicon M221 Logic Controller, Hardware Guide (Version 06)
    Modicon M241 Logic Controller, Programming Guide (Version 07)
    CAD
    Date
    Size
    Add to My Documents
    CAD for TM3DM8R: module TM3 - 8 IO relays (Version 1.0)
    Compact Hardwired Logic Controller M241 - Wiring Diagram (Version 1.0)
    Compact Hardwired Logic Controller M221 - Wiring Diagram (Version 1.0)
    CAD file (on TraceParts) for TM3DM8R: module TM3 - 8 IO relays (Version 2.0)
    Certificate
    Date
    Size
    Add to My Documents
    CSA_2684938_Certificate_M221_TM3 (Version 2.0)
    Date 9/20/17
    Size 151.2 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 8/17/19
    Size 195.3 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 8/17/19
    Size 195.3 KB
    System user guide
    Date
    Size
    Add to My Documents
    Compact Hardwired Logic Controller M221, System User Guide (Version 00)
    Compact Hardwired Logic Controller M241 (Version 00)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    (*)
    8.5 mm/0.33 in. when the clamp is pulled out.


  • Mounting and Clearance

    Spacing Requirements



    Mounting on a Rail


    Incorrect Mounting



    Mounting on a Panel Surface


    (1)
    Install a mounting strip

    Mounting Hole Layout



  • Connections and Schema

    Digital Mixed I/O Module (8-channel)
    Wiring Diagram (Sink / Source)


    (*)
    Type T fuse
    (1)
    The COM0 and COM1 terminals are not connected internally.
    (2)
    To improve the life time of the contacts, and to protect from potential inductive load damage, it is recommended to connect a free wheeling diode in parallel to each inductive DC load or an RC snubber in parallel of each inductive AC load.
    (A)
    Sink wiring (positive logic)
    (B)
    Source wiring (negative logic)
    (C)
    Source wiring (positive logic)
    (D)
    Sink wiring (negative logic)


Compare products: /