USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region
Schneider Eletric STBDRC3210 Picture
Discontinued

Schneider Eletric STBDRC3210 Picture
Discontinued

standard digital output module STB - 24 V 115..230 V AC DC - 2 O

Show more characteristics >
STBDRC3210  has not been replaced. Please contact your customer care center for more information.
  • Price
    104.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon STB distributed I/O solution
    product or component type
    Standard digital output module
    discrete output number
    2
    discrete output type
    Relay
    discrete output function
    2 NO/NC
    discrete output voltage
    115...230 V
    24 V
    discrete output voltage type
    AC
    DC
    Complementary
    discrete output current
    2000 mA
    discrete output logic
    Positive or negative
    output voltage
    5...30 V DC
    20...250 V AC
    response time
    5.25 ms off-to-on
    6.75 ms on-to-off
    switching capacity in VA
    600 VA resistive
    mechanical durability
    1000000 cycles
    electrical durability
    100000 cycles resistive
    cold swapping
    Yes
    hot swapping
    Yes for standard NIMs
    fallback
    State 0 basic NIMs
    User configurable standard NIMs
    protection type
    Coil protection integrated fuse on PDM time lag 10 A
    Output surge protection GMOV
    insulation between channels
    500 V for 1 minute
    insulation between channels and logic bus
    1780 V for 1 minute
    insulation between logic bus and actuator bus
    1500 V for 1 minute
    surge current
    <= 20 A 10 ms capacitive
    minimum load
    50 mA
    reset
    Manual reset COM fault
    product compatibility
    I/O base STBXBA2000
    Power distribution module STBPDT3100/3105
    [Us] rated supply voltage
    24 V DC
    supply
    Power distribution module
    current consumption
    55 mA 5 V DC logic bus
    marking
    CE
    overvoltage category
    II
    status LED
    1 LED green module status (RDY)
    1 LED per channel green channel status (OUT1 to OUT2)
    1 LED red module error (ERR)
    height
    0.72 in (18.4 mm)
    depth
    2.76 in (70 mm)
    width
    5.05 in (128.3 mm)
    product weight
    0.29 lb(US) (0.13 kg)
    Environment
    standards
    EN/IEC 61131-2
    product certifications
    CSA
    FM Class 1 Division 2
    UL
    pollution degree
    2 IEC 60664-1
    operating altitude
    <= 6561.68 ft (2000 m)
    IP degree of protection
    IP20 EN 61131-2 class 1
    ambient air temperature for operation
    32...140 °F (0...60 °C) without derating
    ambient air temperature for operation
    32...140 °F without derating
    ambient air temperature for storage
    -40...85 °C without derating
    ambient air temperature for storage
    -40...185 °F without derating
    relative humidity
    95 % 140 °F (60 °C) without condensation
    vibration resistance
    +/-0.35 mm 10...58 Hz
    3 gn 58...150 Hz 35 x 7.5 mm symmetrical DIN rail
    5 gn 58...150 Hz 35 x 15 mm symmetrical DIN rail
    shock resistance
    30 gn 11 ms IEC 88 reference 2-27
    Ordering and shipping details
    Category
    18215 - ADVANTYS STB I/O
    Discount Schedule
    PC32
    GTIN
    00785901841104
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    0.17999999999999999
    Returnability
    N
    Country of origin
    FR
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    CAD
    Date
    Size
    Add to My Documents
    Relay output module I = 2A U = 24VDC 2 channels (Version 1.0)
  • Technical FAQs

    No results found.