USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region
Schneider Eletric STBACI1230 Picture
Discontinued

Schneider Eletric STBACI1230 Picture
Discontinued

standard analog input module STB - 0..20 mA - 2 I - 12 bits

Show more characteristics >
STBACI1230  has not been replaced. Please contact your customer care center for more information.
  • Price
    497.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon STB distributed I/O solution
    product or component type
    Standard analog input module
    analogue input type
    Current 0...20 mA
    analogue input number
    2
    analogue input resolution
    12 bits
    type of filter
    Single low pass input filter 25 Hz
    Complementary
    absolute maximum input
    25 mA/50 V DC
    response time
    5 ms
    cold swapping
    Yes
    hot swapping fallback
    Yes for standard NIMs
    fallback status
    State 0 basic NIMs
    User configurable standard NIMs
    data format
    IEC 61131-2
    EN 61131-2
    update time
    10 ms
    integral linearity
    +/- 0.1 %FS
    differential linearity
    Monotonic
    input impedance
    <= 300 Ohm
    supply current for sensors
    100 mA per input channels
    protection type
    Short-circuit protection
    absolute accuracy error
    +/- 0.5 % of full scale 25 °C
    temperature drift
    +/-0.01 %/°C
    insulation between channels and logic bus
    1500 V for 1 minute
    insulation between channels and sensor bus
    30 V
    addressing requirement
    4 input words
    product compatibility
    Mounting base STBXBA1000
    Power distribution module STBPDT3100/3105
    [Us] rated supply voltage
    24 V DC
    supply
    Power distribution module
    current consumption
    30 mA 5 V DC logic bus
    marking
    CE
    overvoltage category
    II
    status LED
    1 LED green module status (RDY)
    1 LED red module error (ERR)
    depth
    2.76 in (70 mm)
    height
    0.55 in (13.9 mm)
    width
    5.05 in (128.3 mm)
    product weight
    0.26 lb(US) (0.116 kg)
    Environment
    product certifications
    CSA
    C-Tick
    FM Class 1 Division 2
    ATEX Cat 3G
    UL
    pollution degree
    2 IEC 60664-1
    operating altitude
    <= 6561.68 ft (2000 m)
    IP degree of protection
    IP20 EN 61131-2 class 1
    ambient air temperature for operation
    -13...158 °F (-25...70 °C)
    ambient air temperature for operation
    32...140 °F without derating
    ambient air temperature for storage
    -40...85 °C without derating
    ambient air temperature for storage
    -40...185 °F without derating
    relative humidity
    95 % 140 °F (60 °C) without condensation
    vibration resistance
    +/-0.35 mm 10...58 Hz
    3 gn 58...150 Hz 35 x 7.5 mm symmetrical DIN rail
    5 gn 58...150 Hz 35 x 15 mm symmetrical DIN rail
    shock resistance
    30 gn 11 ms IEC 88 reference 2-27
    Ordering and shipping details
    Category
    18215 - ADVANTYS STB I/O
    Discount Schedule
    PC32
    GTIN
    00785901578659
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    0.14999999999999999
    Returnability
    N
    Country of origin
    FR
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    CAD
    Date
    Size
    Add to My Documents
    Analog input module I = 0 à 20ma 2 channels (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 5/20/19
    Size 195.3 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 5/20/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.