Level control relay RM22-L - 380..415 V AC - 1 C/O

Show more characteristics >
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
  • Price
    72.05 USD
Add to My Products Remove from My Products

  • Main
    range of product
    Zelio Control
    product or component type
    Modular measurement and control relays
    relay type
    Level control relay
    relay name
    RM22L
    relay monitored parameters
    Detection by resistive probes
    time delay type
    Without
    switching capacity in VA
    2000 VA
    measurement range
    5...100 kOhm
    Complementary
    reset time
    <= 1750 ms
    maximum switching voltage
    250 V AC
    minimum switching current
    10 mA at 5 V DC
    maximum switching current
    8 A AC
    [Us] rated supply voltage
    380...415 V AC, 50/60 Hz
    supply voltage limits
    323...456.5 V AC
    operating limits
    - 15 % + 10 % Un
    power consumption in VA
    8 VA AC
    output contacts
    2 C/O
    nominal output current
    8 A
    run-up delay at power-up
    < 0.6 s
    maximum electrode voltage
    12 V AC
    maximum electrode current
    1 mA
    repeat accuracy
    +/- 2 % time delay
    measurement error
    < 1 % over the whole range with voltage variation
    0.05 %/°C with temperature variation
    sensitivity scale
    5...100 kOhm at St (Standard Sensitivity)
    sensitivity adjustment
    5...100 %
    supply current for sensors
    <= 1 mA
    cable distance between devices
    1000 m between probe and delay
    cable capacitance
    1 nF at HS (High Sensitivity) for probe cable
    2.2 nF at St (Standard Sensitivity) for probe cable
    4.7 nF at LS (Low Sensitivity) for probe cable
    overvoltage category
    III conforming to IEC 60664-1
    insulation resistance
    > 100 MOhm at 500 V DC conforming to IEC 60255-27
    insulation
    Between supply and measurement
    mounting position
    Any position
    connections - terminals
    Screw terminals 2 x 0.5...2 x 2.5 mm² - AWG 20...AWG 14, solid cable without cable end
    Screw terminals 2 x 0.2...2 x 1.5 mm² - AWG 24...AWG 16, flexible cable with cable end
    Screw terminals 1 x 0.5...1 x 3.3 mm² - AWG 20...AWG 12, solid cable without cable end
    Screw terminals 1 x 0.2...1 x 2.5 mm² - AWG 24...AWG 14, flexible cable with cable end
    tightening torque
    5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1
    housing material
    Self-extinguishing plastic
    status LED
    LED yellow relay ON
    LED green power ON
    mounting support
    35 mm DIN rail conforming to EN/IEC 60715
    electrical durability
    100000 cycles
    mechanical durability
    10000000 cycles
    utilisation category
    AC-1 conforming to IEC 60947-4-1
    DC-1 conforming to IEC 60947-4-1
    AC-15 conforming to IEC 60947-5-1
    DC-13 conforming to IEC 60947-5-1
    safety reliability data
    MTTFd = 125.5 years
    B10d = 120000
    contacts material
    Cadmium free
    width
    0.89 in (22.5 mm)
    product weight
    0.22 lb(US) (0.1 kg)
    Environment
    immunity to microbreaks
    100 ms DC
    90 ms AC
    electromagnetic compatibility
    Conducted and radiated emissions class B conforming to CISPR 22
    Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1
    Electrostatic discharge 6 kV level 3 contact discharge conforming to IEC 61000-4-2
    Electrostatic discharge 8 kV level 3 air discharge conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test 10 V/m level 3 conforming to IEC 61000-4-3
    Electrical fast transient/burst immunity test 4 kV level 4 direct conforming to IEC 61000-4-4
    Electrical fast transient/burst immunity test 2 kV level 4 capacitive coupling conforming to IEC 61000-4-4
    Surge immunity test 4 kV level 4 common mode conforming to IEC 61000-4-5
    Surge immunity test 2 kV level 4 differential mode conforming to IEC 61000-4-5
    Conducted and radiated emissions class B group 1 conforming to CISPR 11
    Emission standard for industrial environments conforming to EN/IEC 61000-6-4
    Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
    Immunity for industrial environments conforming to EN/IEC 61000-6-2
    standards
    EN/IEC 60255-1
    product certifications
    CCC
    CE
    CSA
    GL
    UL
    RCM
    EAC
    China RoHS
    ambient air temperature for storage
    -40...158 °F (-40...70 °C)
    ambient air temperature for operation
    -20...50 °C at 60 Hz
    -20...60 °C at 50 Hz AC/DC
    relative humidity
    93...97 % at 25...55 °C conforming to IEC 60068-2-30
    vibration resistance
    0.075 mm (f = 10...58.1 Hz) (not in operation) conforming to IEC 60068-2-6
    1 gn (f = 10...58.1 Hz) (not in operation) conforming to IEC 60068-2-6
    0.035 mm (f = 58.1...150 Hz) (in operation) conforming to IEC 60068-2-6
    0.5 gn (f = 58.1...150 Hz) (in operation) conforming to IEC 60068-2-6
    shock resistance
    15 gn for 11 ms (not in operation) conforming to IEC 60068-2-27
    5 gn for 11 ms (in operation) conforming to IEC 60068-2-27
    IP degree of protection
    IP20 on terminals conforming to IEC 60529
    IP40 on housing conforming to IEC 60529
    IP50 on front panel conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    dielectric test voltage
    2.5 kV for 1 min AC 50 Hz conforming to IEC 60255-27
    Ordering and shipping details
    Category
    22380 - RELAYS-MEASUREMENT (RM17-RM35)
    Discount Schedule
    CP2
    GTIN
    00785901481164
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    0.20000000000000001
    Returnability
    N
    Country of origin
    ID
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    California proposition 65
    WARNING: This product can expose you to chemicals including:
    - - - - - - - Substance 1
    Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm.
    - - - - - - - More information
    For more information go to www.p65warnings.ca.gov
  • Documents and Downloads

    Language
    • English
    CAD
    Date
    Size
    Add to My Documents
    CAD for RM22LG11MT: Level control relay RM22-L - 380..415 V AC - 1 C/O (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    CCC Certificate RM22 RM35 (Version 1.0)
    Date 6/25/18
    Size 1.7 MB
    UL Listed RM17, RM22, RM35, RM8487 (Version 1.0)
    EAC Certificate RM4 RM17 RM22 RM35 (Version 1.0)
    CSA Certificate RM17, RM22, RM35, RM8487 (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 3/8/19
    Size 195.3 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 3/8/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



  • Mounting and Clearance

    Mounting and Clearance
    Rail Mounting



  • Connections and Schema

    Level Control Relay

    Wiring Diagram


    A1,A2 : Supply voltage

    Max : High level

    Min : Low level

    C : References or Tank earth electrode

    11-14,12 : 1st C/O contact of output relay


    Control by Electrodes

    Wiring Diagram


    A1,A2 : Supply voltage

    Max : High level

    Min : Low level

    C : References or Tank earth electrode

    11-14,12 : 1st C/O contact of output relay


  • Technical Description

    Function Diagrams
    Control of Two Levels

    Fill/Empty function


    Legend

    Un Nominal supply voltage

    (1) Min. level

    (2) Max. level

    11-12/11-14, 21-22/21-24 Output relay connections

    Relay status: black color = energized.

    Control of One Level

    Empty function T on


    Empty function T off


    Fill function T on


    Fill function T off


    Legend

    Tt Time delay after crossing of threshold

    Un Supply voltage

    (1) Level threshold

    11-12/11-14, 21-22/21-24 Output relay connections