USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region
Schneider Eletric RM0PAS101 Picture
Discontinued

Schneider Eletric RM0PAS101 Picture
Discontinued

insulation control relay - for AS-Interface cabling system - 29.5..31.6 V DC

Show more characteristics >
RM0PAS101  has not been replaced. Please contact your customer care center for more information.
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
  • Price
    432.00 USD
Add to My Products Remove from My Products

  • Main
    range of product
    AS-Interface cabling system
    product or component type
    Insulation control relay
    additional information
    Supplied with an impedance adaptor
    supply
    Via AS-Interface line
    number of outputs
    2 relay, each with 1 NO contact(s)
    Complementary
    System Voltage
    29.5...31.6 V DC measuring input
    50 V DC output relay
    average consumption in mA
    50 mAat 30 V
    response time
    < 20 ms opening of relay contacts (measuring input)
    < 5 ms AS-Interface communication interrupt (measuring input)
    input detection threshold
    < 15 kOhm AS-i + Earth
    < 7 kOhm AS-i - Earth
    [Ith] conventional free air thermal current
    5 Aat 24 V
    [In] rated current
    2 Aat 13 V, U/R = 10 ms
    5 Aat 12 V
    current consumption
    13 mAat 24 Vfor test input and reset input
    voltage state 1 guaranteed
    > 11 V (test input and reset input)
    current state 1 guaranteed
    >= 5 mA (test input and reset input)
    voltage state 0 guaranteed
    < 5 V (test input and reset input)
    current state 0 guaranteed
    <= 2 mA (test input and reset input)
    [Ui] rated insulation voltage
    2000 V between terminals and mounting rails
    installation category
    II conforming to IEC 60664
    fixing mode
    Clip-on, mounting on 35 x 15 mm symmetrical DIN rail on chassis
    Clip-on, mounting on 35 x 15 mm symmetrical DIN rail on mounting plate
    Clip-on, mounting on 35 x 7.5 mm symmetrical DIN rail on chassis
    electrical connection
    Screw terminal block, clamping capacity: 1 x 0.09...1 x 1.5 mm² AWG 28...AWG 16, flexible with cable end
    Screw terminal block, clamping capacity: 1 x 0.14...1 x 2.5 mm² AWG 26...AWG 14, flexible without cable end
    Screw terminal block, clamping capacity: 1 x 0.14...1 x 4 mm² AWG 26...AWG 12, solid
    Screw terminal block, clamping capacity: 2 x 0.09...2 x 0.75 mm² AWG 28...AWG 20, flexible with cable end
    Screw terminal block, clamping capacity: 2 x 0.2...2 x 2.5 mm² AWG 24...AWG 14, solid
    tightening torque
    5.31 lbf.in (0.6 N.m) with flat Ø 3.5 mm screwdriver
    width
    3.54 in (90 mm)
    height
    2.99 in (76 mm)
    depth
    2.28 in (58 mm)
    local signalling
    1 LED green, function: output relays energised
    1 LED green, function: reset input at state 1
    1 LED green, function: supply to relay on and no fault present
    1 LED red, function: insulation fault, polarity AS-Interface -
    1 LED red, function: insulation fault, polarity AS-Interface +
    1 LED yellow, function: test input at state 1
    product weight
    0.57 lb(US) (0.26 kg)
    Environment
    product certifications
    AS-Interface No 16701
    standards
    EN/IEC 60204-1
    EN/IEC 60204-2
    IEC 61131-2 Type 2
    IP degree of protection
    IP2x conforming to IEC 60529
    resistance to incandescent wire
    1382 °F (750 °C), extinction time: < 30 s conforming to IEC 60695-2-1
    shock resistance
    15 gn 11 ms conforming to IEC 60068-2-27
    vibration resistance
    0.7 gn (f = 5...100 Hz) conforming to IEC 60068-2-6
    resistance to electrostatic discharge
    6 kV on contact conforming to IEC 61000-4-2
    8 kV in open air conforming to IEC 61000-4-2
    resistance to radiated fields
    13.72 V/yd (15 V/m), radio frequency fields = 80...1000 Hz conforming to IEC 61000-4-3
    resistance to fast transients
    1 kV on the inputs conforming to IEC 61000-4-4
    2 kV AS-Interface conforming to IEC 61000-4-4
    ambient air temperature for operation
    23...140 °F (-5...60 °C)
    ambient air temperature for storage
    -13...158 °F (-25...70 °C)
    pollution degree
    2 conforming to IEC 60654
    Ordering and shipping details
    Category
    18325 - SERIPLEX SOFTWARE&CABLES DISC SPX2
    Discount Schedule
    SPX2
    GTIN
    00785901449768
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    0.64000000000000001
    Returnability
    N
    Country of origin
    LV
    Offer Sustainability
    RoHS (date code: YYWW)
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.