time delay relay 8 functions - 0.05..1 s - 240 V AC DC - 2OC

Show more characteristics >
  • Price
    277.00 USD
Add to My Products Remove from My Products

RE7MY13MW is replaced by:
Product
Qty
RE22R2MYMR
Qty
1
Add to My Products Remove from My Products
  • Reason for Substitution: End of life
  • Substitution date: 01 January 2017
  • Main
    range of product
    Zelio Time
    product or component type
    Industrial timing relay
    contacts type and composition
    2 C/O
    component name
    RE7
    time delay type
    A
    C
    D
    Di
    H
    Qg
    Qt
    W
    time delay range
    0.05 s...300 h
    Complementary
    discrete output type
    Relay
    contacts material
    90/10 silver nickel contacts
    width pitch dimension
    0.89 in (22.5 mm)
    [Us] rated supply voltage
    24...240 V AC/DC at 50/60 Hz
    voltage range
    0.85...1.1 Us
    connections - terminals
    Screw terminals, clamping capacity: 2 x 1.5 mm² flexible with cable end
    Screw terminals, clamping capacity: 2 x 2.5 mm² flexible without cable end
    tightening torque
    5.31...9.73 lbf.in (0.6...1.1 N.m)
    setting accuracy of time delay
    +/- 10 % of full scale
    repeat accuracy
    +/- 0.2 %
    temperature drift
    < 0.07 %/°C
    voltage drift
    < 0.2 %/V
    minimum pulse duration
    20 ms
    reset time
    50 ms
    maximum switching voltage
    250 V AC/DC
    mechanical durability
    20000000 cycles
    [Ith] conventional free air thermal current
    8 A
    [Ie] rated operational current
    <= 2 A DC-13 24 Vat 158 °F (70 °C) conforming to IEC 60947-5-1/1991/VDE 0660
    <= 3 A AC-15at 158 °F (70 °C) conforming to IEC 60947-5-1/1991/VDE 0660
    <= 0.1 A DC-13 250 Vat 158 °F (70 °C) conforming to IEC 60947-5-1/1991/VDE 0660
    <= 0.2 A DC-13 115 Vat 158 °F (70 °C) conforming to IEC 60947-5-1/1991/VDE 0660
    minimum switching capacity
    12 V / 10 mA
    input voltage
    < 60 V X1Z2 terminal(s)
    < 60 V Y1Z2 terminal(s)
    maximum switching current
    1 mA X1Z2 terminal(s)
    1 mA Y1Z2 terminal(s)
    input compatibility
    3/4 wires sensors PNP/NPN without internal load 50 m X1Z2 terminal(s)
    3/4 wires sensors PNP/NPN without internal load 50 m Y1Z2 terminal(s)
    potentiometer characteristic
    Linear 47 kOhm (+/- 20 %), 0.2 W, cable length: 25 m Z1Z2terminal(s)
    marking
    CE
    overvoltage category
    III conforming to IEC 60664-1
    [Ui] rated insulation voltage
    250 V between contact circuit and control inputs IEC certified
    250 V between contact circuit and power supply IEC certified
    300 V between contact circuit and control inputs CSA certified
    300 V between contact circuit and power supply CSA certified
    supply disconnection value
    > 0.1 Uc
    operating position
    Any position without derating
    surge withstand
    2 kV conforming to IEC 61000-4-5 level 3
    power consumption in VA
    2 VA 24 V
    6 VA 240 V
    2.5 VA 48 V
    3.2 VA 110 V
    power consumption in W
    1 W 48 V
    2 W 24 V
    2 W 240 V
    3.2 W 110 V
    peak current
    0.001 kAfor 30 s on energisation
    terminal description
    (15-16-18)OC_OFF
    (25-26-28)OC_OFF
    (A1-A2)CO
    (X1)UNUSED
    (Y1)UNUSED
    (Z1)UNUSED
    (Z2)UNUSED
    height
    3.07 in (78 mm)
    width
    0.89 in (22.5 mm)
    depth
    3.15 in (80 mm)
    product weight
    0.33 lb(US) (0.15 kg)
    Environment
    immunity to microbreaks
    3 ms
    standards
    EN/IEC 61812-1
    product certifications
    CSA
    GL
    UL
    ambient air temperature for storage
    -40...185 °F (-40...85 °C)
    ambient air temperature for operation
    -4...140 °F (-20...60 °C)
    relative humidity
    15...85 % (3K3) conforming to IEC 60721-3-3
    vibration resistance
    0.35 mm (f = 10...55 Hz) conforming to IEC 60068-2-6
    shock resistance
    15 gn 11 ms conforming to IEC 60068-2-27
    IP degree of protection
    IP20 (terminals)
    IP50 (housing)
    pollution degree
    3 conforming to IEC 60664-1
    dielectric strength
    2.5 kV
    non-dissipating shock wave
    4.8 kV
    resistance to electrostatic discharge
    6 kV (in contact) conforming to IEC 61000-4-2 level 3
    8 kV (in air) conforming to IEC 61000-4-2 level 3
    resistance to electromagnetic fields
    9.14 V/yd (10 V/m) conforming to IEC 61000-4-3 level 3
    resistance to fast transients
    2 kV conforming to IEC 61000-4-4 level 3
    disturbance radiated/conducted
    CISPR 11 group 1 - class A
    CISPR 22 - class A
    Ordering and shipping details
    Category
    22376 - RELAYS-MEASUREMENT(RM4)
    Discount Schedule
    CP2
    GTIN
    00785901481447
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    0.33000000000000002
    Returnability
    N
    Country of origin
    ID
    Contractual warranty
    Warranty period
    18 months
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Width 22.5 mm
    Rail Mounting


    Screw Fixing



  • Connections and Schema

    Internal Wiring Diagram



    Recommended Application Wiring Diagram
    Start on Energisation


    1
    Supply
    2
    12…48 V
    3
    24 V


    Recommended Application Wiring Diagram
    Start by External Control


    1
    Supply
    2
    12…48 V
    3
    24 V


    Recommended Application Wiring Diagram
    External Control of Partial Stop


    1
    Supply
    2
    12…48 V
    3
    24 V


    Control of Several Relays

    Control of several relays with a single external control contact



    Connection of Potentiometer



    Connection Precautions

    WARNING

    UNEXPECTED EQUIPMENT OPERATION

    No galvanic isolation between supply terminals and control inputs.

    Failure to follow these instructions can result in death, serious injury, or equipment damage.



  • Performance Curves

    Performance Curves
    A.C. Load Curve 1

    Electrical durability of contacts on resistive loading millions of operating cycles


    X
    Current broken in A
    Y
    Millions of operating cycles

    A.C. Load Curve 2

    Reduction factor k for inductive loads (applies to values taken from durability curve 1).


    X
    Power factor on breaking (cos ϕ)
    Y
    Reduction factor k

    Example: An LC1-F185 contactor supplied with 115 V/50 Hz for a consumption of 55 VA or a current consumption equal to 0.1 A and cos ϕ = 0.3. For 0.1 A, curve 1 indicates a durability of approximately 1.5 million operating cycles. As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2. For cos ϕ = 0.3: k = 0.6 The electrical durability therefore becomes:1.5 106 operating cycles x 0.6 = 900 000 operating cycles.


    D. C. Load Limit Curve


    X
    Current in A
    Y
    Voltage in V
    1
    L/R = 20 ms
    2
    L/R with load protection diode
    3
    Resistive load


  • Technical Description

    Function A : Power on Delay Relay
    Description

    The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function C : Off-Delay Relay with Control Signal
    Description

    After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function D : Symmetrical Flasher Relay (Starting Pulse Off)
    Description

    Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.

    The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function Di : Symmetrical Flasher Relay (Starting Pulse On)
    Description

    Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.

    The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function H : Interval Relay
    Description

    On energisation of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)


    Function Qg: Star-Delta Timing
    Description

    Timing for star-delta starter with contact for switching to star connection.

    Function: 1 Output



    Function Qt: Star-Delta Timing
    Description

    Timing for star-delta starter with double On-delay period.

    Function: 1 Output



    Function W : Interval Relay with Control Signal Off
    Description

    After power-up and opening of the control contact, the output(s) close(s) for a timing period T.

    At the end of this timing period the output(s) revert(s) to its/their initial state.

    The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).


    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    C

    Control contact

    G

    Gate

    R

    Relay or solid state output

    R1/R2

    2 timed outputs

    R2 inst.

    The second output is instantaneous if the right position is selected

    T

    Timing period

    Ta -

    Adjustable On-delay

    Tr -

    Adjustable Off-delay

    U

    Supply