time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC

Show more characteristics >
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price*
    86.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Time
    product or component type
    Electronic timing relay
    electrical connection
    11 pin plug-in sub-base
    discrete output type
    Relay
    contacts type and composition
    2 C/O timed contacts AgNi (cadmium free)
    component name
    RE48A
    time delay type
    A
    B
    C
    Di
    time delay range
    0.5...30 s
    0.2...12 h
    5...300 s
    2...120 min
    5...300 min
    2...120 h
    0.2...12 s
    2...120 s
    0.5...30 h
    0.02...1.2 s
    0.5...30 min
    5...300 h
    0.05...3 s
    0.2...12 min
    [Us] rated supply voltage
    24...240 V AC/DC 50/60 Hz
    voltage range
    0.85...1.1 Us AC
    0.9...1.1 Us DC
    Line Rated Current
    5 A
    Complementary
    product front plate size
    48 x 48 mm
    control type
    Selector switch on front panel
    housing material
    Self-extinguishing
    repeat accuracy
    +/- 0.2 % of the maximum setting value conforming to IEC 61812-1
    temperature drift
    +/- 0.02 %/°C of the maximum setting value conforming to IEC 61812-1
    voltage drift
    +/- 0.2 %/V of the maximum setting value at 48...240 V
    +/- 1 %/V of the maximum setting value at 24...48 V
    setting accuracy of time delay
    +/- 5 % of full scale at 25 °C conforming to IEC 61812-1
    minimum pulse duration
    20 ms
    reset time
    >= 25 ms on de-energisation
    pick up duration
    55 ms
    on-load factor
    100 %
    power consumption in VA
    1.1 VA at 24 V
    4.8 VA at 240 V
    power consumption in W
    1.7 W at 240 V
    0.5 Wat 24 V
    breaking capacity
    1250 VA
    minimum switching current
    100 mA
    maximum switching current
    5 A
    maximum switching voltage
    250 V AC/DC
    electrical durability
    100000 cycles
    mechanical durability
    30000000 cycles
    output voltage
    240 V at 5 A AC-12
    30 V at 2 A DC-13
    240 V at 1.5 A AC-15
    marking
    CE
    surge withstand
    1 kV differential mode conforming to IEC 61000-4-5 level 3
    2 kV common mode conforming to IEC 61000-4-5 level 3
    mounting support
    Panel mounted: system supplied with the product
    Base mounted: socket
    local signalling
    1 LED yellow output relay state
    LED indicator green flashing: relay energised timing in progress
    LED indicator green on steady: relay energised, no timing in progress
    product weight
    0.31 lb(US) (0.14 kg)
    Environment
    humidity drift
    +/- 0.05 %/%RH of the maximum setting value conforming to IEC 61812-1
    immunity to microbreaks
    < 10 ms
    dielectric strength
    1 kV at 1 mA/1 minute conforming to IEC 61812-1
    protection against electric shocks
    4 kV class III conforming to IEC 60664-1
    4 kV class III conforming to IEC 61812-1
    standards
    89/336/EEC
    IEC 60669-2-3
    IEC 61812-1
    EN 50082-1/2
    EN 50081-1/2
    73/23/EEC
    93/68/EEC
    product certifications
    UL
    cULus
    C-Tick
    CSA
    GL
    ambient air temperature for storage
    -40...158 °F (-40...70 °C)
    ambient air temperature for operation
    -4...122 °F (-20...50 °C)
    IP degree of protection
    IP40 housing conforming to IEC 60529
    IP50 front face conforming to IEC 60529
    vibration resistance
    0.35 mm 10...55 Hz conforming to IEC 60068-2-6
    relative humidity
    93 % without condensation conforming to IEC 60068-2-3
    resistance to electrostatic discharge
    6 kV at in contact conforming to EN/IEC 61000-4-2 level 3
    8 kV at in air conforming to EN/IEC 61000-4-2 level 3
    resistance to electromagnetic fields
    10 V/m 26 MHz to 1 GHz conforming to IEC 61000-4-3 level 3
    resistance to fast transients
    2 kV capacitive connecting clip conforming to EN/IEC 61000-4-4 level 4
    4 kV direct conforming to EN/IEC 61000-4-4 level 4
    immunity to radioelectric fields
    10 V at 0.15...80 MHz conforming to EN/IEC 61000-4-6 level 3
    immunity to voltage dips
    30 % for 10 ms conforming to EN/IEC 61000-4-11
    60 % for 100 ms conforming to EN/IEC 61000-4-11
    95 % for 5 s conforming to EN/IEC 61000-4-11
    disturbance radiated/conducted
    Class B at 0.15...30 MHz conforming to EN 55022 (EN 55011 group 1)
    Ordering and shipping details
    Category
    22370 - RE, RM MISC TIMERS & COUNTERS
    Discount Schedule
    CP2
    GTIN
    00785901834922
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    0.28000000000000003
    Returnability
    Y
    Country of origin
    ID
    Offer Sustainability
    California proposition 65
    WARNING: This product can expose you to chemicals including:
    - - - - - - - Substance 1
    Nickel compounds, which is known to the State of California to cause cancer, and
    - - - - - - - Substance 2
    Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm.
    - - - - - - - More information
    For more information go to www.p65warnings.ca.gov
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    Catalog
    Date
    Size
    Add to My Documents
    Digest 178 Catalog 23: Relays and Timers (Version 1.0)
    CAD
    Date
    Size
    Add to My Documents
    CAD for RE48AML12MW: time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC (Version 1.0)
    CAD file (on TraceParts) for RE48AML12MW: time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC (Version 2.0)
    Certificate
    Date
    Size
    Add to My Documents
    CCC Certificate RE48A (Version 1.0)
    Date 5/23/19
    Size 1.7 MB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Width 48 mm



  • Mounting and Clearance

    Panel Cut-Out and Mounting
    Panel Cut-Out


    n
    Number of devices mounted side-by-side

    Mounting

    Cover positioning and mounting


    e
    Panel thickness
    1
    Protective cover
    2
    Panel mounting frame
    3
    Locating screw


  • Connections and Schema

    Wiring Diagram



  • Technical Description

    Function A : Power on Delay Relay
    Description

    The timing period T begins on energisation. After timing, the output R closes.


    T = t1 + t2 + t3


    Function B : Interval Relay with Control Signal
    Description

    After power-up, pulsing or maintaining control contact C starts the timing T. The output R closes for the duration of the timing period T then reverts to its initial state.


    T = t1 + t2 + t3


    Function C : Off-Delay Relay with Control Signal
    Description

    After power-up and closing of the control contact, the output closes. When control contact re-opens, timing T starts. At the end of the timing period, the output reverts to their initial state.


    T = t1 + t2 + t3


    Function Di : Symmetrical Flasher Relay (Starting Pulse On)
    Description

    Repetitive cycle with two timing periods T of equal duration, with output changing state at the end of each timing period T.



    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    C

    Control contact

    G

    Gate

    R

    Relay or solid state output

    R1/R2

    2 timed outputs

    R2 inst.

    The second output is instantaneous if the right position is selected

    T

    Timing period

    Ta -

    Adjustable On-delay

    Tr -

    Adjustable Off-delay

    U

    Supply