View all Zelio Time

Zelio Time - RE22R2MYMR

Relay Output

Schneider Eletric RE22R2MYMR Picture
View all Zelio Time

Zelio Time - RE22R2MYMR

Relay Output

Multi-function Timing Relay - 0.05s…300h - 24…240V AC/DC - 2C/O

Show more characteristics >
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price
    79.16 USD
Add to My Products Remove from My Products

  • Main
    range of product
    Zelio Time
    product or component type
    Modular timing relay
    discrete output type
    Relay
    device short name
    RE22
    nominal output current
    8 A
    Complementary
    contacts type and composition
    1 C/O timed or instantaneous contact, cadmium free
    2 C/O timed contact, cadmium free
    time delay type
    A
    At
    Aw
    C
    D
    Di
    H
    Ht
    Qg
    Qt
    W
    Ct
    Dw
    Hw
    Wt
    Dt
    Dit
    Diw
    Qgt
    Qtt
    Qgw
    Qtw
    time delay range
    0.05...1 s
    0.3...3 s
    1...10 s
    10...100 s
    3...30 h
    3...30 min
    3...30 s
    30...300 h
    30...300 min
    30...300 s
    control type
    Rotary knob
    Diagnostic button
    External potentiometer
    [Us] rated supply voltage
    24...240 V AC/DC at 50/60 Hz
    input voltage
    <= 2.4 V
    voltage range
    0.85...1.1 Us
    supply frequency
    50...60 Hz (+/- 5 %)
    connections - terminals
    Screw terminals : 1 x 0.5...1 x 3.3 mm², AWG 20...AWG 12 solid cable without cable end
    Screw terminals : 2 x 0.5...2 x 2.5 mm², AWG 20...AWG 14 solid cable without cable end
    Screw terminals : 1 x 0.2...1 x 2.5 mm², AWG 24...AWG 14 flexible cable with cable end
    Screw terminals : 2 x 0.2...2 x 1.5 mm², AWG 24...AWG 16 flexible cable with cable end
    tightening torque
    5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1
    housing material
    Self-extinguishing
    repeat accuracy
    +/- 0.5 % conforming to IEC 61812-1
    temperature drift
    +/- 0.05 %/°C
    voltage drift
    +/- 0.2 %/V
    setting accuracy of time delay
    +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
    minimum pulse duration
    100 ms (with load in parallel)
    30 ms
    insulation resistance
    100 MOhm at 500 V DC conforming to IEC 60664-1
    reset time
    120 ms (on de-energisation)
    immunity to microbreaks
    <= 10 ms
    power consumption in VA
    3 VA at 240 V AC
    power consumption in W
    1.5 W at 240 V DC
    switching capacity in VA
    2000 VA
    minimum switching current
    10 mA 5 V DC
    maximum switching current
    8 A
    maximum switching voltage
    250 V AC
    electrical durability
    100000 cycles for 8 A at 250 V AC-1
    100000 cycles for 2 A at 24 V DC-1
    mechanical durability
    10000000 cycles
    [Uimp] rated impulse withstand voltage
    5 kV 1.2...50 µs conforming to IEC 60664-1
    delay response
    < 100 ms
    creepage distance
    4 kV/3 conforming to IEC 60664-1
    overvoltage category
    III conforming to IEC 60664-1
    safety reliability data
    MTTFd = 171.2 years
    B10d = 160000
    mounting position
    Any position
    mounting support
    35 mm DIN rail conforming to EN/IEC 60715
    status LED
    Green LED backlight (steady) dial pointer indication
    Yellow LED (steady) output relay energised
    Yellow LED (fast flashing) timing in progress and output relay de-energised
    Yellow LED (slow flashing) timing in progress and output relay energised
    width
    0.89 in (22.5 mm)
    product weight
    0.23 lb(US) (0.105 kg)
    Environment
    dielectric strength
    2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1
    standards
    IEC 61812-1
    UL 508
    directives
    2004/108/EC - electromagnetic compatibility
    2006/95/EC - low voltage directive
    product certifications
    CCC
    CE
    CSA
    GL
    UL
    RCM
    EAC
    China RoHS
    ambient air temperature for operation
    -4...140 °F (-20...60 °C)
    ambient air temperature for storage
    -40...158 °F (-40...70 °C)
    IP degree of protection
    IP20(terminals) conforming to IEC 60529
    IP40 (housing) conforming to IEC 60529
    IP50 (front panel) conforming to IEC 60529
    pollution degree
    3 conforming to IEC 60664-1
    vibration resistance
    20 m/s² (f = 10...150 Hz) conforming to IEC 60068-2-6
    shock resistance
    15 gn (not operating) (duration = 11 ms) conforming to IEC 60068-2-27
    5 gn (in operation) (duration = 11 ms) conforming to IEC 60068-2-27
    relative humidity
    95 % at 25...55 °C
    electromagnetic compatibility
    Fast transients immunity test (test level: 1 kV, level 3 - capacitive connecting clip) conforming to IEC 61000-4-4
    Surge immunity test (test level: 1 kV, level 3 - differential mode) conforming to IEC 61000-4-5
    Surge immunity test (test level: 2 kV, level 3 - common mode) conforming to IEC 61000-4-5
    Electrostatic discharge (test level: 6 kV, level 3 - contact discharge) conforming to IEC 61000-4-2
    Electrostatic discharge (test level: 8 kV, level 3 - air discharge) conforming to IEC 61000-4-2
    Radiated radio-frequency electromagnetic field immunity test (test level: 10 V/m, level 3 - 80 MHz...1 GHz) conforming to IEC 61000-4-3
    Conducted RF disturbances (test level: 10 V, level 3 - 0.15...80 MHz) conforming to IEC 61000-4-6
    Fast transient bursts (test level: 2 kV, level 3 - direct contact) conforming to IEC 61000-4-4
    Immunity to microbreaks and voltage drops (test level: 30 % - 500 ms) conforming to IEC 61000-4-11
    Immunity to microbreaks and voltage drops (test level: 100 % - 20 ms) conforming to IEC 61000-4-11
    Ordering and shipping details
    Category
    22376 - RELAYS-MEASUREMENT(RM4)
    Discount Schedule
    CP2
    GTIN
    00785901330288
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    0.25
    Returnability
    Y
    Country of origin
    ID
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    California proposition 65
    WARNING: This product can expose you to chemicals including:
    - - - - - - - Substance 1
    Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm.
    - - - - - - - More information
    For more information go to www.p65warnings.ca.gov
  • Documents and Downloads

    Language
    • English
    Certificate
    Date
    Size
    Add to My Documents
    Date 8/6/18
    Size 1.5 MB
    UL Listed RE17, RE22, REXL, RE48A, RE88857, RE88865, RE88867, RENF22R2MMW
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



  • Connections and Schema

    Wiring Diagram



  • Technical Description

    Function A: Power On-Delay
    Description

    On energisation of power supply, the timing period T starts. After timing, the output(s) R close(s).The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    Function: 2 Outputs



    Function At: Power On-Delay with Pause / Summation Control
    Description

    On energisation of power supply, the timing period T starts.Timing can be interrupted / paused each time X1 energizes.Except for RE17*, RE22R2AMU, RE22R2MMW, RE22R2MMU, RE22R2MJU, timing can be interrupted / paused each time Y1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R close(s).The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output with Pause / Summation Control


    T =
    t1 + t2 +…

    Function: 2 Outputs with Pause / Summation Control


    T =
    t1 + t2 +…

    Function: 1 Output with Retrigger / Restart Control


    T =
    t1 + t2 +…

    Function: 2 Outputs with Retrigger / Restart Control


    T =
    t1 + t2 +…


    Function Aw : Power On-Delay With Retrigger / Restart Control
    Description

    On energisation of power supply, the timing period T starts.At the end of the timing period T, the output(s) R close(s).Energization of Y1 makes the output(s) R open(s).Deenergization of Y1 restarts timing period T.At the end of timing period T, the output(s) R close(s).The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST")

    Function: 1 Output


    Function: 2 Outputs



    Function C: Off-Delay Relay with Control Signal
    Description

    After energisation of power supply and energization of Y1 causes output(s) R close(s). When Y1 deenergizes, timing T starts.At the end of this timing period T,the output(s) R revert(s) to its/their initial position.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    Function: 2 Outputs



    Function Ct: Off-Delay Relay with Control Signal & With Pause / Summation Control
    Description

    After energisation of power supply and energization of Y1 cause output(s) R close(s).When Y1 deenergizes, timing starts and the timing can be interrupted / paused each time X1 energizes. When the cumulative total of time periods elapsedreaches the pre-set value T, the output(s) R revert(s) to its/their initial state.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    T =
    t1 + t2 +…

    Function: 2 Outputs


    T =
    t1 + t2 +…


    Function D: Symmetrical Flashing Relay (Starting Pulse Off)
    Description

    On energisation of power supply, output(s) R starts at its/their initial state for timing duration T then change(s) to output(s) R close(s) for the same timing duration T.This cycle is repeated indefintely until power supply removal.Specially for RE17*, RE22R2AMU, RE22R2MMW, RE22R2MMU, RE22R2MJU,this D function can only be initiated by energizing Y1 permanently.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    Function: 2 Outputs


    Function: 1 Output with Retrigger / Restart Control


    Function: 2 Output with Retrigger / Restart Control



    Function Dt: Symmetrical Flashing Relay (Starting Pulse Off) & With Pause / Summation Control
    Description

    On energisation of power supply, output(s) R starts at its/their initial state for timing duration T and the timing can be interrupted / paused each time X1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, then changes to output(s) R close(s).The output(s) R close state will remain for the same timing duration T and the timing can be interrupted / paused each time X1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial state.This cycle is repeated indefintely until power supply removal.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    T =
    t1 + t2 +…
    T =
    t'1 + t'2 +…

    Function: 2 Outputs


    T =
    t1 + t2 +…
    T =
    t'1 + t'2 +…


    Function DW: Symmetrical Flashing Relay (Starting Pulse Off) & With Retrigger / Restart Control
    Description

    On energisation of power supply, output(s) R starts at its/their initial state for timing duration T then change(s) to output(s) R close(s) for the same timing duration T.This cycle is repeated indefintely until power supply removal.Specially for RE17*, RE22R2AMU, RE22R2MMW, RE22R2MMU, RE22R2MJU,this D function can only be initiated by energizing Y1 permanently.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    Function: 2 Outputs



    Function Di: Symmetrical Flashing Relay (Starting Pulse On)
    Description

    On energisation of power supply, output(s) R starts at output(s) R close(s) for timing duration T then revert(s) to its/their initial state for the same timing duration T.This cycle is repeated indefintely until power supply removal.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    Function: 2 Outputs



    Function Dit: Symmetrical Flashing Relay (Starting Pulse On) & With Pause / Summation Control
    Description

    On energisation of power supply, output(s) R starts at output(s) R close(s) for timing duration T and the timing can be interrupted / paused each time X1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, then revert(s) to its/their initial state.The output(s) R at initial state will remain for the same timing duration T and the timing can be interrupted / paused each time X1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R change(s) to close state.This cycle is repeated indefintely until power supply removal.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    T =
    t1 + t2 +…
    T =
    t'1 + t'2 +…

    Function: 2 Outputs


    T =
    t1 + t2 +…
    T =
    t'1 + t'2 +…


    Function Diw: Symmetrical Flashing Relay (Starting Pulse On) & With Retrigger / Restart Control
    Description

    On energisation of power supply, output(s) R starts at output(s) R close(s) for timing duration T then revert(s) to its/their initial state for the same timing duration T.This cycle is repeated indefintely until power supply removal.At any state of the output(s) R when Y1 energizes, the output(s) R will revert to its/their initial state and followed by Y1 deenergizes then restarts the same operation as described at the beginning.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    Function: 2 Outputs



    Function H: Interval Relay
    Description

    On energisation of power supply, output(s) R close(s) and timing period T starts.At the end of the timing period T, the output(s) R revert(s) to its/their initial state.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    Function: 2 Outputs



    Function Ht: Interval Relay & With Pause / Summation Control
    Description

    On energisation of power supply, output(s) R close(s) and timing period T starts.The timing can be interrupted / paused each time X1 energizes. When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial stateReenergization of X1 will also cause output(s) R close(s) if the time has elapsed and restart the same operation as described at the beginning.Except for RE17*, RE22R2AMU, RE22R2MMW, RE22R2MMU, RE22R2MJU, timing can be interrupted / paused each time Y1 energizes.The second output (R2) can be either timed (when set to "TIMED" or instantaneous (when set to "INST").

    Function: 1 Output


    T =
    t1 + t2 +…

    Function: 2 Outputs


    T =
    t1 + t2 +…

    Function: 1 Output with Retrigger / Restart Control


    T =
    t1 + t2 +…

    Function: 2 Output with Retrigger / Restart Control


    T =
    t1 + t2 +…


    Function Hw: Interval Relay & with Retrigger / Restart Control
    Description

    On energisation of power supply, output(s) R close(s) and timing period T starts.At the end of the timing period T, the output(s) R revert(s) to its/their initial state.At any state of the output(s) R when Y1 energizes followed by deenergizes, the output(s) R close(s) then restarts the same operation as described at the beginning.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    Function: 2 Outputs



    Function Qg: Star-Delta Relay (2 CO with same Common)
    Description

    On energisation of power supply, the output R3 closes such that energizes STAR CONTACTOR + MAIN CONTACTOR and the timing T starts (STAR connection time duration starts).At the end of the timing period T, the output R3 reverts to its initial state such that deenergizes STAR CONTACTOR and causes t transition time starts.At the end of the transition time, the output R4 closes such that energizes DELTA CONTACTOR.

    Function: 2 Outputs


    t :
    20, 40, 60, 80, 100, 120, 140 ms


    Function Qgt: Star-Delta Relay (2 CO with same common) with Pause / Summation Control
    Description

    On energisation of power supply, the output R3 closes such that energizes STAR CONTACTOR + MAIN CONTACTOR and the timing T starts (STAR connection time duration starts).During STAR connection time, the timing can be interrupted / paused each time X1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, R3 reverts to its initial state such that deenergizes STAR CONTACTOR and causes t transition time starts.At the end of the transition time, the output R4 closes such that energizes DELTA CONTACTOR.

    Function: 2 Outputs


    T =
    t1 + t2 +…

    NOTE: RE22R2MYMR is with fixed transition time, t: 50ms


    Function Qt: Star-Delta Relay (2 CO with Split Common)
    Description

    On energisation of power supply, the output R3 & R4 initializes at its initial state such that energizes STAR CONTACTOR + MAIN CONTACTOR and the timing T starts (STAR connection time duration starts).At the end of the timing period T, the output R3 closes such that deenergizes STAR CONTACTOR and causes t transition time starts.At the end of the transition time, the output R4 closes such that energizes DELTA CONTACTOR.

    Function: 2 Outputs


    t :
    20, 40, 60, 80, 100, 120, 140 ms


    Function Qtt: Star-Delta Relay (2 CO with same common) with Pause / Summation Control
    Description

    On energisation of power supply, the output R3 & R4 initializes at its initial state such that energizes STAR CONTACTOR + MAIN CONTACTOR and the timing T starts (STAR connection time duration starts).During STAR connection time, the timing can be interrupted / paused each time X1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, the output R3 closes such that deenergizes STAR CONTACTOR and causes t transition time starts.At the end of the transition time, the output R4 closes such that energizes DELTA CONTACTOR.

    Function: 2 Outputs


    T =
    t1 + t2 +…

    NOTE: RE22R2MYMR is with fixed transition time, t: 50ms


    Function W: Interval Relay with Control Signal Off
    Description

    After energisation of power supply and on energization of Y1 following by denergization of Y1, the output(s) R close(s) and starts the timing T.At the end of the timing period, the output(s) R revert(s) to its/their initial state.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    Function: 2 Outputs



    Function Wt: Interval Relay with Control Signal Off & with Pause / Summation Control
    Description

    After energisation of power supply and on energization of Y1 following by denergization of Y1, the output(s) R close(s) and starts the timing T.Timing can be interrupted / paused each time X1 energizes.When the cumulative total of time periods elapsed reaches the pre-set value T, the output(s) R revert(s) to its/their initial state.The second output (R2) can be either timed (when set to "TIMED") or instantaneous (when set to "INST").

    Function: 1 Output


    T =
    t1 + t2 +…

    Function: 2 Outputs


    T =
    t1 + t2 +…

    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    U -

    Supply

    R1/R2 -

    2 timed outputs

    Ta -

    Adjustable On-delay

    Tr -

    Adjustable Off-delay

    X1 -

    Pause / Summation control

    Y1 -

    Retrigger / Restart control

    X2 -

    Function Selection

    R2 inst. -

    The second output is instantaneous if the right position is selected

    T -

    Timing period

    R4 -

    Delta contact output

    t -

    Delay to switch ON Delta contact output

    R3 -

    Star-Delta contact output