USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all Zelio Time
Schneider Eletric RE17RMXMU Picture

RE17RMXMU

Schneider Eletric RE17RMXMU Picture
RE17RMXMU

time delay relay 9 functions - 1 s..100 h - 24..240 V AC - 1 OC

Show more characteristics >
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price*
    75.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Zelio Time
    product or component type
    Modular timing relay
    discrete output type
    Relay
    width
    0.69 in (17.5 mm)
    device short name
    RE17R
    time delay type
    Ah
    Tl
    N
    Tt
    Ad
    Pt
    O
    W
    P
    time delay range
    6...60 s
    1...10 min
    0.1...1 s
    1...10 h
    1...10 s
    6...60 min
    10...100 h
    nominal output current
    8 A
    Complementary
    contacts type and composition
    1 C/O
    contacts material
    Cadmium free
    height
    3.54 in (90 mm)
    depth
    2.83 in (72 mm)
    control type
    Selector switch front panel
    [Us] rated supply voltage
    24...240 V AC 50/60 Hz
    24 V DC
    voltage range
    0.85...1.1 Us
    supply frequency
    50...60 Hz +/- 5 %
    release of input voltage
    10 V
    connections - terminals
    Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end
    Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end
    Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
    tightening torque
    5.31…8.85 lbf.in (0.6…1 N.m) IEC 60947-1
    housing material
    Self-extinguishing
    repeat accuracy
    +/- 0.5 % IEC 61812-1
    temperature drift
    +/- 0.05 %/°C
    voltage drift
    +/- 0.2 %/V
    setting accuracy of time delay
    +/- 10 % of full scale 25 °C IEC 61812-1
    control signal pulse width
    100 ms with load in parallel typical
    30 ms typical
    insulation resistance
    100 MOhm 500 V DC IEC 60664-1
    reset time
    120 ms on de-energisation typical
    on-load factor
    100 %
    power consumption in VA
    0…32 VA 240 V AC
    maximum power consumption in W
    0.6 W 24 V DC
    minimum switching current
    10 mA 5 V DC
    maximum switching current
    8 A AC/DC
    maximum switching voltage
    250 V AC
    breaking capacity
    2000 VA
    operating frequency
    10 Hz
    electrical durability
    100000 cycles resistive 8 A 250 V AC
    mechanical durability
    10000000 cycles
    dielectric strength
    2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
    [Uimp] rated impulse withstand voltage
    5 kV 1.2/50 µs
    power on delay
    100 ms
    marking
    CE
    creepage distance
    4 kV/3 IEC 60664-1
    safety reliability data
    MTTFd = 296.8 years
    B10d = 270000
    mounting position
    Any position in relation to normal vertical mounting plane
    mounting support
    35 mm DIN rail EN/IEC 60715
    local signalling
    LED indicator on steady: relay energised, no timing in progress
    LED indicator 80 % ON and 20 % OFF flashing: timing in progress
    LED indicator 5 % ON and 95 % OFF pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L)
    net weight
    0.15 lb(US) (0.07 kg)
    time delay type
    Ad, Ah, N, O, P, Pt, TI, Tt, W
    functionality
    Multifunction
    compatibility code
    RE17
    Environment
    immunity to microbreaks
    20 ms
    standards
    2006/95/EC
    2004/108/EC
    EN 61000-6-1
    EN 61000-6-4
    EN 61000-6-2
    EN 61000-6-3
    IEC 61812-1
    product certifications
    CULus
    GL
    CSA
    ambient air temperature for storage
    -22…140 °F (-30…60 °C)
    ambient air temperature for operation
    -4…140 °F (-20…60 °C)
    IP degree of protection
    IP20 IEC 60529 terminal block)
    IP40 IEC 60529 housing)
    IP50 IEC 60529 front panel)
    vibration resistance
    20 m/s² 10…150 Hz)IEC 60068-2-6
    shock resistance
    15 gn 11 ms IEC 60068-2-27
    relative humidity
    93 % without condensation IEC 60068-2-30
    electromagnetic compatibility
    Electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2
    Electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2
    Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3
    Electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4
    Electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4
    1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5
    1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5
    Conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6
    Voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11
    Voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11
    Conducted and radiated emissionsclass B EN 55022
    Ordering and shipping details
    Category
    22370 - RE, RM MISC TIMERS & COUNTERS
    Discount Schedule
    CP2
    GTIN
    00785901525677
    Package weight(Lbs)
    0.08 kg (0.17 lb(US))
    Returnability
    Yes
    Country of origin
    ID
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
  • Documents

    Language
    • English
    Catalog
    Date
    Size
    Add to My Documents
    Digest 178 Catalog 23: Relays and Timers (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    UL Listed RE17, RE22, REXL, RE48A, RE88857, RE88865, RE88867, RENF22R2MMW (Version 1.0)
    CCC Certificate Timer RE10 RE17 iRT (Version 1.0)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    REACh Declaration
    Date
    Size
    Add to My Documents
    RoHs China Declaration
    Date
    Size
    Add to My Documents
    Date 9/23/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Width 17.5 mm



  • Connections and Schema

    Internal Wiring Diagram



    Wiring Diagram


    1) Contact Y1:

    • Control for functions B, C, Ac, Bw, Ad, Ah, N, O, W, T, Tt.

    • Partial stop for functions At, Ht and Pt.

    • Function D if Di selected.

    • Not used for functions A, H and P.


  • Technical Description

    Function Ad : Pulse Delayed Relay with Control Signal
    Description

    After power-up, pulsing or maintaining of control contact C starts the timing T.

    At the end of this timing period T, the output R closes.

    The output R will be reset the next time control contact C is pulsed or maintained.

    Function: 1 Output



    Function Ah : Pulse Delayed Relay (Single Cycle) with Control Signal
    Description

    After power-up, pulsing or maintaining of control contact C starts the timing T. A single cycle then starts with 2 timing periods T of equal duration (start with output in rest position).

    Output R closes at the end of the first timing period T and reverts to its initial position at the end of the second timing period T.

    Control contact C must be reset in order to re-start the single flashing cycle.

    Function: 1 Output



    Function N : Retriggerable Interval Relay with Control Signal On
    Description

    After power-up and an initial control pulse C, the output R closes.

    If the interval between two control pulses C is greater than the set timing period T, timing elapses normally and the output R closes at the end of the timing period. If the interval is not greater than the set timing period, the output R remains closed until this condition is met.

    Function: 1 Output



    Function O : Retriggerable Interval Delayed Relay with Control Signal On
    Description

    An initial timing period T begins on energisation. At the end of this timing period, the output R closes.

    As soon as there is a control pulse C, the output R reverts to its initial state until the interval between two control pulses is less than the value of the set timing period T. Otherwise, the output R closes at the end of the timing period T.

    Function: 1 Output



    Function P : Pulse Delayed Relay with Fixed Pulse Length
    Description

    The timing period T begins on energisation.

    At the end of this period, the output R closes for a fixed time P.

    Function: 1 Output


    P = 500 ms


    Function Pt : Pulse Delayed Relay (Summation and Fixed Pulse Length) with Control Signal Off
    Description

    On energisation, timing period T starts (it can be interrupted by operating the Gate control contact G).

    At the end of this period, the output R closes for a fixed time P.

    Function: 1 Output


    T = t1 + t2 + ...

    P = 500 ms


    Function TL : Bistable Relay with Control Signal On
    Description

    After power-up, pulsing or maintaining of control contact Y1 switches the output on.

    A second pulse on the control contact Y1 switches the output relay off.



    Function Tt : Retriggerable Bistable Relay with Control Signal On
    Description

    After power-up, pulsing or maintaining of control contact C switches output R on and starts timing T.

    The output switches off at the end of the timing period T or following a second pulse on the control contact C.

    Function: 1 Output



    Function W : Interval Relay with Control Signal Off
    Description

    After power-up and opening of the control contact, the output(s) close(s) for a timing period T.

    At the end of this timing period the output(s) revert(s) to its/their initial state.

    The second output can be either timed or instantaneous.

    Function: 1 Output


    Function: 2 Outputs


    2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.).


    Legend

    Relay de-energised

    Relay energised

    Output open

    Output closed

    C

    Control contact

    G

    Gate

    R

    Relay or solid state output

    R1/R2

    2 timed outputs

    R2 inst.

    The second output is instantaneous if the right position is selected

    T

    Timing period

    Ta -

    Adjustable On-delay

    Tr -

    Adjustable Off-delay

    U

    Supply


Compare products: /