on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output
Show more characteristics >-
Product availabilityNon-Stock - Not normally stocked in distribution facility
-
Characteristics
Main range of product Zelio Timeproduct or component type Modular timing relaydiscrete output type Solid statewidth 0.69 in (17.5 mm)component name RE17Ltime delay type Htime delay range 0.1...1 s1...10 h1...10 min1...10 s10...100 h6...60 min6...60 snominal output current 0.7 AComplementary control type Selector switch on front panel[Us] rated supply voltage 24...240 V AC at 50/60 Hzvoltage range 0.85...1.1 Ussupply frequency 50...60 Hz (+/- 5 %)release of input voltage 9 Vcontrol signal pulse width 0.05 s typicalinsulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1[Uimp] rated impulse withstand voltage 5 kV (1.2/50 µs)power on delay < 100 msconnections - terminals Screw terminals, clamping capacity: 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12 (solid) without cable endScrew terminals, clamping capacity: 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14 (solid) without cable endScrew terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14 (flexible) with cable endScrew terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16 (flexible) with cable endtightening torque 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1housing material Self-extinguishingrepeat accuracy +/- 0.5 % conforming to IEC 61812-1temperature drift +/- 0.05 %/°Cvoltage drift +/- 0.2 %/Vsetting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1reset time 350 ms on de-energisation typicalon-load factor 100 %power consumption in VA 0...3 VA at 240 V ACpower consumption in W <= 1.5 W at 240 V DCbreaking capacity 0.5 A AC/DC conforming to UL0.7 A AC/DC at 68 °F (20 °C)operating frequency 10 Hzmaximum output current 20 A <= 10 msminimum switching current 10 mAleakage current < 5 mAmaximum switching voltage 250 V ACvoltage drop 4 V 3-wire8 V 2-wireelectrical durability 100000000 cyclesmarking CEcreepage distance 4 kV/3 conforming to IEC 60664-1safety reliability data MTTFd = 353.8 yearsB10d = 320000mounting position Any position in relation to normal vertical mounting planemounting support 35 mm DIN rail conforming to EN/IEC 60715product weight 0.15 lb(US) (0.068 kg)Environment immunity to microbreaks <= 20 msderating factor 5 mA/°Cstandards 2004/108/ECEN 61000-6-1EN 61000-6-2EN 61000-6-3EN 61000-6-4IEC 61812-12006/95/ECproduct certifications CSAcULusGLambient air temperature for storage -22...140 °F (-30...60 °C)ambient air temperature for operation -4...140 °F (-20...60 °C)IP degree of protection IP20 (terminal block) conforming to IEC 60529IP40 (housing) conforming to IEC 60529IP50 (front panel) conforming to IEC 60529vibration resistance 20 m/s² (f = 10...150 Hz) conforming to IEC 60068-2-6shock resistance 15 gn (duration = 11 ms) conforming to IEC 60068-2-27relative humidity 93 % without condensation conforming to IEC 60068-2-30electromagnetic compatibility Electrostatic discharge immunity test, in contact at 6 kV conforming to IEC 61000-4-2 level 3Electrostatic discharge immunity test, in air at 8 kV conforming to IEC 61000-4-2 level 3Susceptibility to electromagnetic fields, 80 MHz to 1 GHz at 10 V/m conforming to IEC 61000-4-3 level 3Electrical fast transient/burst immunity test, capacitive connecting clip at 1 kV conforming to IEC 61000-4-4 level 3Electrical fast transient/burst immunity test, direct at 2 kV conforming to IEC 61000-4-4 level 31.2/50 µs shock waves immunity test, differential mode at 1 kV conforming to IEC 61000-4-5 level 31.2/50 µs shock waves immunity test, common mode at 2 kV conforming to IEC 61000-4-5 level 3Conducted RF disturbances, 0.15...80 MHz at 10 V conforming to IEC 61000-4-6 level 3Voltage dips and interruptions immunity test, 1 cycle at 0 % conforming to IEC 61000-4-11Voltage dips and interruptions immunity test, 25/30 cycles at 70 % conforming to IEC 61000-4-11Conducted and radiated emissions conforming to EN 55022 class BOrdering and shipping details Category 22370 - RE, RM MISC TIMERS & COUNTERSDiscount Schedule CP2GTIN 00785901002901Nbr. of units in pkg. 1Package weight(Lbs) 1.25Returnability NCountry of origin IDOffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile AvailableProduct end of life instructions AvailableCalifornia proposition 65 WARNING: This product can expose you to chemicals including:- - - - - - - Substance 1 Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm.- - - - - - - More information For more information go to www.p65warnings.ca.gov -
Documents and Downloads
Language- English
- Spanish
- French
CatalogSizeAdd to My DocumentsDigest Catalog 23: Relays and Timers (Version 1.8)CertificateSizeAdd to My DocumentsUL Listed RE17, RE22, REXL, RE48A, RE88857, RE88865, RE88867, RENF22R2MMW (Version 1.0)Date 8/3/18Size 344 BDate 8/3/18Size 322 BREACh DeclarationSizeAdd to My DocumentsEU RoHS DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Width 17.5 mm -
Connections and Schema
Internal Wiring DiagramWiring Diagram -
Technical Description
Function H : Interval RelayDescriptionOn energisation of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.
Function: 1 OutputFunction: 2 Outputs2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
LegendRelay de-energised
Relay energised
Output open
Output closed
CControl contact
GGate
RRelay or solid state output
R1/R22 timed outputs
R2 inst.The second output is instantaneous if the right position is selected
TTiming period
Ta -Adjustable On-delay
Tr -Adjustable Off-delay
USupply