USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Select your location
View all Modicon OTB
Schneider Eletric OTB1C0DM9LP Picture

OTB1C0DM9LP

Schneider Eletric OTB1C0DM9LP Picture
OTB1C0DM9LP

I/O distributed module OTB - CANopen bus - 0..1000 m

Show more characteristics
Commercial status
To be discontinued on 29 November 2019
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
  • Price*
    850.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon OTB
    product or component type
    I/O distributed module
    integrated connection type
    CANopen bus SUB-D 9 2 twisted shielded pairs 10 kbit/s...1 Mbit/s
    bus type
    CANopen S20 DS 401 V2.1 CSMA/MA multimaster with priority DR303-2
    CANopen S20 DS 401 V2.1 CSMA/MA multimaster with priority DS301 V4.02
    discrete input number
    12 EN/IEC 61131 type 1
    discrete input logic
    Sink or source
    discrete input current
    5 mA I0...I1
    5 mA I6...I7
    7 mA I2...I5
    7 mA I8...I11
    discrete output number
    2 solid state PNP Q0...Q1 source
    6 relay Q2...Q7
    discrete output current
    2000 mA relay
    300 mA solid state
    Complementary
    topology
    Devices linked by daisy-chaining or tap junctions
    number of slave
    63
    bus length
    0.00…328.08 ft (0…100 m) 0.00…32.81 ft (0…10 m), 500 kbit/s
    0.00…3280.84 ft (0…1000 m) 0.00…393.70 ft (0…120 m), 50 kbit/s
    0.00…820.21 ft (0…250 m) 0.00…32.81 ft (0…10 m), 250 kbit/s
    0.00…8202.10 ft (0…2500 m) 0.00…984.25 ft (0…300 m), 20 kbit/s
    0.00…131.23 ft (0…40 m) 0.00…19.69 ft (0…6 m), 800 kbit/s
    0.00…1640.42 ft (0…500 m) 0.00…32.81 ft (0…10 m), 125 kbit/s
    0.00…16404.20 ft (0…5000 m) 0.00…1968.50 ft (0…600 m), 10 kbit/s
    0.00…65.62 ft (0…20 m), 1 Mbit/s
    number of devices per segment
    0…16 672.57 ft (205 m)
    0…32 606.96 ft (185 m)
    0…64 524.93 ft (160 m)
    discrete input voltage
    24 V
    discrete input voltage type
    DC
    discrete input type
    NPN or PNP
    input voltage limits
    20.4...26.4 V
    electronic filtering time
    0.035 ms I0...I1 at state 1
    0.035 ms I6...I7 at state 1
    0.04 ms I2...I5 at state 1
    0.04 ms I8...I11 at state 1
    0.045 ms I0...I1 at state 0
    0.045 ms I6...I7 at state 0
    0.15 ms I2...I5 at state 0
    0.15 ms I8...I11 at state 0
    configurable filtering time
    12 ms
    0 ms
    3 ms
    input impedance
    3.4 kOhm I2...I5
    3.4 kOhm I8...I11
    5.7 kOhm I0...I1
    5.7 kOhm I6...I7
    discrete output voltage
    24 V DC solid state
    240 V AC relay
    30 V DC relay
    output voltage limits
    20.4...28.8 V solid state
    maximum output current
    360 mA, solid state
    maximum current per output common
    8 A relay
    0.72 A solid state
    current consumption
    30 mA 5 V DC at state 1) relay output
    40 mA 24 V DC at state 1) relay output
    5 mA 5 V DC at state 0) relay output
    output overvoltage protection
    38...40 V
    maximum tungsten load
    <8 W solid state
    response time
    300 µs at state 0 relay
    300 µs at state 1 relay
    5 µs at state 0 solid state
    5 µs at state 1 solid state
    minimum switchable load
    0.1 mA
    contact bounce time
    <= 1 ms relay
    maximum leakage current
    0.1 mA at state 0 solid state
    drop-out voltage
    1 V at state 1
    insulation between channel and internal logic
    1500 Vrms for 1 minute relay output
    500 Vrms for 1 minute input circuit
    500 Vrms for 1 minute solid state output
    insulation between channels
    None
    contact resistance
    30 mOhm
    electrical durability
    500000 cycles AC-1 500 VA relay output
    500000 cycles AC-14 250 VA relay output
    500000 cycles AC-15 200 VA relay output
    500000 cycles DC-1 60 W relay output
    500000 cycles DC-13 30 W relay output
    supply circuit type
    DC
    [Us] rated supply voltage
    24 V
    supply voltage limits
    20.4…26.2 V
    input current
    700 mA 26.2 V supply circuit
    inrush current
    1 A solid state output
    50 A supply circuit
    power consumption in W
    19 W
    maximum number of I/O expansion module
    7
    I/O expansion capacity
    132 screw terminal discrete I/O
    188 spring terminal discrete I/O
    244 HE10 connector discrete I/O
    7 x 8I or 7 x 2I or 7 x (4I/2O) screw terminal analogue I/O
    insulation resistance
    >= 10 MOhm between I/O and earth terminals
    >= 10 MOhm between power supply and earth
    I/O connection
    Removable screw terminal block
    number of common point
    1 relay output 1 NO)
    1 relay output 2 NO)
    1 relay output 3 NO)
    1 input
    1 solid state output
    counting input number
    2
    counting capacity
    32 bits
    counting frequency
    20000 Hz
    5000 Hz
    pulse generator number
    2
    pulse generator frequency
    7 kHz
    pulse generator function
    RPWM pulse width modulation
    RPLS pulse generator output
    marking
    CE
    fixing mode
    By clips 35 mm symmetrical DIN rail)
    By screws panel with fixing kit)
    By screws solid plate with fixing kit)
    status LED
    I/O 1 LED per channel green)
    PWR 1 LED green)
    RUN 1 LED green)
    ERR 1 LED red)
    net weight
    0.43 lb(US) (0.195 kg)
    Environment
    IP degree of protection
    IP20
    immunity to microbreaks
    10 ms supply circuit
    dielectric strength
    500 V between I/O and earth terminals
    500 V between power supply and earth
    standards
    CSA
    UL 508
    EN 61131-2
    CSA C22.2 No 213 Class I Division 2 Group D
    CSA C22.2 No 213 Class I Division 2 Group B
    CSA C22.2 No 213 Class I Division 2 Group A
    IEC 61131-2
    CSA C22.2 No 213 Class I Division 2 Group C
    product certifications
    CULus
    ambient air temperature for operation
    32…131 °F (0…55 °C)
    ambient air temperature for storage
    -13…158 °F (-25…70 °C)
    relative humidity
    30…95 % without condensation
    pollution degree
    2 EN 60664
    2 IEC 60664
    operating altitude
    0...6561.68 ft (0...2000 m)
    storage altitude
    0.00…9842.52 ft (0…3000 m)
    vibration resistance
    0.075 mm 10…57 Hz 35 mm symmetrical DIN rail
    1 gn 57…150 Hz 35 mm symmetrical DIN rail
    shock resistance
    15 gn 11 ms EN 61131
    15 gn 11 ms IEC 61131
    resistance to electrostatic discharge
    4 kV in contact IEC 61000-4-2
    8 kV in air EN 61000-4-2
    8 kV in air IEC 61000-4-2
    4 kV in contact EN 61000-4-2
    resistance to radiated fields
    9.14 V/m (10 V/m) 80000000…2000000000 Hz EN 61000-4-3
    9.14 V/m (10 V/m) 80000000…2000000000 Hz IEC 61000-4-3
    resistance to fast transients
    1 kV IEC 61000-4-4 24 V solid state I/O)
    2 kV IEC 61000-4-4 24 V supply)
    Ordering and shipping details
    Category
    18217 - ADVANTYS OTB
    Discount Schedule
    PC12
    GTIN
    00785901428718
    Package weight(Lbs)
    0.31 kg (0.68 lb(US))
    Returnability
    No
    Country of origin
    FR
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    California proposition 65
    WARNING: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen & Reproductive harm. For more information go to www.p65warnings.ca.gov
    REACh Regulation
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
    Contractual warranty
    Warranty
    18 months
  • Documents

    Language
    • English
    Catalog
    Date
    Size
    Add to My Documents
    Modicon OTB Interface Modules - Modicon TM2 Expansion Modules (Version 1.0)
    CAD
    Date
    Size
    Add to My Documents
    CAD file (on TraceParts) for OTB1C0DM9LP: I/O distributed module OTB - CANopen bus - 0..1000 m (Version 2.0)
    OTB 3D CAD files (Version 1.0)
    Date 8/14/12
    Size 1.4 MB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 10/15/19
    Size 195.3 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 10/15/19
    Size 195.3 KB
    RoHs China Declaration
    Date
    Size
    Add to My Documents
    Date 10/15/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
Compare products: /