USA

Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

PowerLogic EM4900 Multi-Circuit Meter – 14x3P circuits - Ethernet and Serial

Show more characteristics >
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
Add to My Products Remove from My Products

  • Main
    range
    PowerLogic
    product or component type
    Multi-circuit energy meter
    product name
    PowerLogic EM4900E
    device short name
    EM4914
    power monitoring
    Basic instrumentation
    energy management
    Sub billing and cost allocation
    Billing analysis
    device application
    Sub billing
    type of measurement
    Apparent power total
    Apparent power per phase
    Active power total
    Active power per phase
    Phase angle
    Current average
    Power factor average
    Current per phase, rms
    Active energy
    Power factor per phase
    metering type
    Demand current I1, I2, I3, peak demand current IM1, IM2, IM3
    Demand power P
    [Us] rated supply voltage
    100...277 V AC at 50/60 Hz
    network frequency
    50 Hz
    60 Hz
    Complementary
    sampling rate
    256 samples/cycle
    current transformer input
    Solid core CT, 0.333 V x 42 (single pole)
    Solid core CT, 0.333 V x 21 (single phase)
    Solid core CT, 0.333 V x 14 (three phase)
    Split core CT, 0.333 V x 42 (single pole)
    Split core CT, 0.333 V x 21 (single phase)
    Split core CT, 0.333 V x 14 (three phase)
    measurement voltage
    150...480 V AC 50/60 Hz between phases
    90...277 V AC 50/60 Hz between phase and neutral
    measurement accuracy
    +/- 0.5 % of the measuring range power
    +/- 0.5 % of the measuring range energy
    +/- 0.5 % of the measuring range current
    +/- 0.5 % of the measuring range voltage
    communication port protocol
    BACnet MS/TP
    Modbus RTU 2 wires, : 9600, 19200, 38400 bps, even/odd or none,
    Modbus TCP 2 wires, : 9600, 19200, 38400 bps, even/odd or none,
    SNMP
    BACnet IP : 10, 100 Mbits,
    communication port support
    RS485 spring connector
    RJ45
    data update rate
    2 s (Modbus)
    14 s (BACnet)
    20 s (SNMP)
    data recording
    Maximum of instantaneous current
    Maximum of demand current
    Maximum of demand active power
    communication of data
    Over voltage alarm
    Under voltage alarm
    High-high current alarm
    High current alarm
    Low current alarm
    Low-low current alarm
    Total energy
    web services
    Web server
    communication service
    Updating firmware
    Environment
    mounting mode
    Wall mount
    installation category
    III
    pollution degree
    2
    ambient air temperature for operation
    32...140 °F (0...60 °C)
    ambient air temperature for storage
    -40...158 °F (-40...70 °C)
    standards
    UL 508
    IEC 61010
    width
    9.96 in (253 mm)
    depth
    12.09 in (307 mm)
    height
    2.76 in (70 mm)
    product weight
    3.31 lb(US) (1.5 kg)
    Ordering and shipping details
    Category
    09793 - PLOGIC BRANCH CIRCUIT BCPM & MCM
    Discount Schedule
    PL1
    GTIN
    00785901021483
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    9.5
    Returnability
    N
    Offer Sustainability
    California proposition 65
    WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
  • Documents and Downloads

    Language
    • English
    Technical leaflet
    Date
    Size
    Add to My Documents
    EM4900 Multi-Circuit Meter Technical Datasheet - US Web Version (Version 1.0)
    EM4900 Multi-Circuit Meter Technical Datasheet - US Print Version (Version 1.0)
  • Technical FAQs

    No results found.