USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

Enercept Meter, class 0.2S, Modbus/BACnet RS485, Split Core 100A, ANSI wire code

Show more characteristics >
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    PowerLogic
    product name
    PowerLogic EM4200
    device short name
    Enercept
    product or component type
    Energy meter
    type of cable
    ANSI cable
    device application
    Power monitoring
    Complementary
    metering type
    Active power P, P1, P2, P3
    Apparent power S, S1, S2, S3
    Frequency
    Power factor
    Reactive power Q, Q1, Q2, Q3
    Voltage U21, U32, U13, V1, V2, V3
    Average current Iavg
    Active, reactive, apparent energy (signed, four quadrant)
    Demand power P, Q, S
    Peak demand power PM, QM, SM
    accuracy class
    Class 1 according to ANSI C12.1)
    Class 1S according to IEC 62053-22)
    measurement accuracy
    1 %
    measurement current
    0...100 A
    measurement voltage
    90 V AC 45...65 Hz minimum per phase
    480 V AC 45...65 Hz between phases
    300 V AC 45...65 Hz between phase and neutral
    frequency measurement range
    45...65 Hz
    network frequency
    50 Hz
    60 Hz
    Line Rated Current
    100 A
    display type
    Without display
    local signalling
    Green and red LED: status
    Green, orange and red LED: line fault, 3 pulse/ k_h (kWh, kVAh, kVARh)
    Yellow LED: dial pointer indication
    Green, orange and red LED: RX/TX, 2 pulse/ k_h (kWh, kVAh, kVARh)
    Signal
    Voltage (impedance 2.5 MOhm) single phase
    Voltage (impedance 5 MOhm) phase to phase
    Split core current transducer 0.333 V (impedance 33 kOhm)
    number of inputs
    0
    number of outputs
    0
    communication port protocol
    Modbus RTU: 9600 bauds...115200 bauds (automatic detection),
    BACnet MS/TP: 9600 bauds...115200 bauds (automatic detection),
    communication of data
    Remote control orders
    Net energy
    Total energy
    Demand intervals
    Fixed or rolling block
    External synchronisation to communication
    provided equipment
    Bracket for support
    Hook
    Fuse
    Split core current transducer 3
    connections - terminals
    Input/output: bottom plug-in connector 0...0 in² (0.2...1.5 mm²)
    Current transformer: bottom plug-in connector 0...0 in² (0.2...1.5 mm²)
    Communication: bottom plug-in connector 0...0 in² (0.2...1.5 mm²)
    wire stripping length
    0.24 in (6 mm)
    mounting mode
    By screws
    Clip-on
    By hook
    mounting support
    DIN rail
    Enclosure
    standards
    EN 61010-1
    UL 61010-1
    CAN/CSA C22.2 No. 1010.1-92
    product certifications
    CULus conforming to UL 61010-1
    CE conforming to EN 61010-1
    BTL
    ANSI
    width
    1.84 in (46.63 mm)
    depth
    35.81 mm
    height
    6 in (152.36 mm)
    Environment
    measurement category
    Category III up to 277 V
    Category III up to 300 V
    electromagnetic compatibility
    ● conducted and radiated emissions, conforming to FCC part 15 class A
    ● conducted and radiated emissions, conforming to EN 61000-6-4
    ● conducted and radiated emissions, conforming to EN 61326 + A1
    ● immunity to conducted disturbances, conforming to EN 61000-6-2
    ● immunity to conducted disturbances, conforming to EN 61326-1
    ● immunity to radiated fields, conforming to EN 61000-6-2
    ● immunity to radiated fields, conforming to EN 61326-1
    IP degree of protection
    IP20 conforming to IEC 60529
    relative humidity
    0...95 %
    pollution degree
    2
    ambient air temperature for operation
    -22...158 °F (-30...70 °C)
    ambient air temperature for storage
    -40...185 °F (-40...85 °C)
    operating altitude
    < 9842.52 ft (3000 m)
    Ordering and shipping details
    Category
    09791 - POWERLOGIC ENERCEPT POWER METER
    Discount Schedule
    PL1
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    3.3399999999999999
    Returnability
    N
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.