Multi 9 - N40 Vigi - 1P + N - 6A - C curve - class AC - 240 V - 30 mA - 6 kA

Show more characteristics >
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    Multi 9
    product name
    Multi 9 N40 Vigi
    product or component type
    Residual current breaker with overcurrent protection (RCBO)
    device short name
    N40 Vigi
    device application
    Distribution
    poles description
    1P + N
    neutral position
    Left
    number of protected poles
    1
    [In] rated current
    6 A at 122 °F (50 °C) conforming to EN/IEC 60947-2
    network type
    AC
    trip unit technology
    Thermal-magnetic
    curve code
    C
    earth-leakage sensitivity
    30 mA
    earth-leakage protection time delay
    Instantaneous
    earth-leakage protection class
    Type AC
    breaking capacity
    Icn 6000 A at 240 V AC 50 Hz conforming to EN/IEC 61009-1
    Icu 6 kA at 240 V AC 50 Hz conforming to EN/IEC 60947-2
    utilisation category
    Category A conforming to EN/IEC 60947-2
    suitability for isolation
    Yes conforming to EN/IEC 60947-2
    Complementary
    network frequency
    50 Hz
    System Voltage
    240 V AC 50 Hz
    magnetic tripping limit
    8.5 x In +/- 20 % AC
    residual current tripping technology
    Voltage independent
    [Ics] rated service breaking capacity
    4.5 kA 75 % x Icu at 240 V AC 50 Hz conforming to EN/IEC 60947-2
    rated breaking and making capacity
    Idm 4500 A at 240 V AC 50 Hz conforming to EN/IEC 61009-1
    limitation class
    3 conforming to EN/IEC 61009-1
    [Ui] rated insulation voltage
    400 V AC 50 Hz conforming to EN/IEC 60947-2
    [Uimp] rated impulse withstand voltage
    4 kV conforming to EN/IEC 60947-2
    contact position indicator
    Yes
    control type
    Toggle
    local signalling
    Fault indication
    ON/OFF indication
    mounting mode
    Clip-on
    mounting support
    DIN rail
    9 mm pitches
    4
    height
    3.19 in (81 mm)
    width
    1.42 in (36 mm)
    depth
    2.76 in (70 mm)
    product weight
    0.28 lb(US) (0.125 kg)
    colour
    Grey
    mechanical durability
    20000 cycles
    electrical durability
    20000 cycles
    provision for padlocking
    Padlockable
    connections - terminals
    Tunnel type terminal, top or bottom rigid wire(s) 0...0.02 in² (0.75...16 mm²) max
    Tunnel type terminal, top or bottom flexible wire(s) 0...0.02 in² (0.33...10 mm²) max
    Tunnel type terminal, top or bottom flexible with ferrule wire(s) 0...0.02 in² (0.33...10 mm²) max
    wire stripping length
    0.51 in (13 mm) (top or bottom)
    tightening torque
    17.7 lbf.in (2 N.m) (top or bottom)
    earth-leakage protection
    Integrated
    Environment
    standards
    EN/IEC 61009-1
    EN/IEC 60947-2
    IP degree of protection
    IP40 modular enclosure conforming to IEC 60529
    IP20 conforming to IEC 60529
    pollution degree
    3 conforming to EN/IEC 60947-2
    overvoltage category
    IV
    electromagnetic compatibility
    8/20 µs impulse withstand 250 A
    tropicalisation
    2 conforming to IEC 60068-1
    relative humidity
    95 % ( 131 °F (55 °C) )
    ambient air temperature for operation
    23...140 °F (-5...60 °C)
    ambient air temperature for storage
    -22...158 °F (-30...70 °C)
    Ordering and shipping details
    Category
    00908 - C60N SUPPLEMENTARY PROTECTORS
    Discount Schedule
    DE2
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    2.8199999999999998
    Returnability
    N
  • Documents and Downloads

    Language
    • English
    Catalog
    Date
    Size
    Add to My Documents
    Multi 9 - Catalogue 2018 - Multistandard protection for OEM (Version 2.3)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.