USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

ION8650 meter 32MB, 9S/29S/36S, 120VAC/160VDC 60Hz, Full comm No I/O

Show more characteristics >
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    PowerLogic
    device short name
    ION8650C
    product or component type
    Energy and power quality meter
    Complementary
    power quality analysis
    Harmonic distortion
    Programmablity (logic and math functions)
    Voltage sag and swell detection
    Up to the 31st harmonic
    device application
    Tariff metering
    Co-generation and IPP monitoring
    Demand and power factor control
    Load curtailment
    Equipment monitoring and control
    Energy pulsing and totalisation
    Instrument transformer correction
    type of measurement
    Apparent power total
    Apparent power per phase
    Active power total
    Active power per phase
    Reactive power total
    Reactive power per phase
    Voltage
    Current
    Frequency
    Power factor total
    Power factor per phase
    supply voltage
    120...277 V AC 47...63 Hz
    80...160 V DC
    65...120 V AC 47...63 Hz
    network frequency
    60 Hz
    outlet standard
    American
    Line Rated Current
    1 A
    2 A
    5 A
    type of network
    1P + N
    3P
    3P + N
    power consumption in VA
    24 VA
    <= 33 VA
    display type
    FSTN transflective LCD
    form designation
    9S 3-element 4-wire
    36S 2½-element 4-wire
    29S 2½-element 4-wire
    sampling rate
    1024 samples/cycle
    measurement current
    0.001...24 A
    input type
    Current 0.01...20 A 0.05 Ohm
    measurement voltage
    57...277 V AC phase to neutral
    100...480 V AC phase to phase
    number of inputs
    0
    measurement accuracy
    0.1 % current
    0.1 % voltage
    0.1 % power
    0.1 % power factor
    0.001 Hz frequency
    0.1 % energy
    accuracy class
    Class 0.2S energy conforming to IEC 62053-22
    Class 0.2S energy conforming to IEC 62053-23
    Class 0.2 energy conforming to ANSI C12.20
    number of outputs
    2 pulse
    communication port protocol
    DNP3: 300...115200 bauds,
    ION: 300...115200 bauds,
    Ansi C12.18: <= 19200 bauds,
    TCP/IP : 10/100 Mbit/s,
    IEC 61850 ed. 2 : 10/100 Mbit/s,
    DLMS : 300...115200 bauds,
    Modbus : 57600 bauds,
    TCP/IP : 300...57600 bauds,
    DNP3 : 10/100 Mbit/s,
    ION : 10/100 Mbit/s,
    ModemGate
    Modbus RTU slave : 300...115200 bauds,
    Modbus TCP slave : 10/100 Mbit/s,
    EtherGate
    communication port support
    Ethernet RJ45
    Modem RJ11
    Infrared
    RS485 terminal block
    RS485/RS232 SUB-D 9
    time synchronisation protocol
    IRIG-B
    GPS: Truetime/Datum
    data recording
    Alarms
    Data logs
    Event logs
    Time stamping
    GPS synchronisation
    Revenue logs
    Historical logs
    Harmonics logs
    Sag and swell logs
    transmission rate
    10/100 Mbit/s
    300...57600 bauds
    57600 bauds
    300...115200 bauds
    <= 19200 bauds
    memory capacity
    32 MB
    web services
    Alarm notification by e-mail
    Web server
    Port addressing user designed
    Robust security logs
    Ethernet service
    SNMP-Traps and SYSLOG
    Enable/disable serial ports
    Enable/disable Ethernet protocols
    tamperproof of settings
    Protected by access code
    Environment
    electromagnetic compatibility
    ● electrostatic discharge immunity test, conforming to IEC 61000-4-2
    ● susceptibility to electromagnetic fields, conforming to IEC 61000-4-3
    ● electrical fast transient/burst immunity test, conforming to IEC 61000-4-4
    ● 1.2/50 µs shock waves immunity test, conforming to IEC 61000-4-5
    ● conducted RF disturbances, conforming to IEC 61000-4-6
    ● immunity to impulse waves, conforming to IEC 61000-4-12
    ● conducted and radiated emissions class B, conforming to CISPR 22
    mounting mode
    Socket-mounted
    mounting support
    Enclosure door
    type of installation
    Indoor installation
    overvoltage category
    III
    IP degree of protection
    IP51 back
    IP65 front face
    relative humidity
    5...95 %
    pollution degree
    2
    ambient air temperature for operation
    -40...185 °F (-40...85 °C)
    ambient air temperature for storage
    -40...185 °F (-40...85 °C)
    operating altitude
    0...9842.52 ft (0...3000 m)
    standards
    ANSI C12.1
    IEC 62052-11
    width
    7.01 in (178 mm)
    depth
    9.33 in (237 mm)
    height
    7.01 in (178 mm)
    product weight
    15.43 lb(US) (7 kg)
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  0801  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Reference contains SVHC above the threshold  -  Go to CaP for more details
    Go to CaP for more details
    Product environmental profile
    Available
    Product end of life instructions
    Available
    California proposition 65
    WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Russian
    • French
    User guide
    Date
    Size
    Add to My Documents
    PowerLogic ION8650 User Guide - EN (Version 03)
    ION Reference -EN (Version 10)
    Date 11/26/18
    Size 9.5 MB
    IEC 61000-4-30 compliance and ION meters -EN (Version 12)
    PowerLogic ION8650 Manuel d’utilisation (Version 03)
    PowerLogic ION8650 cellular modem option (Version 01)
    What's new in PowerLogic ION8650 firmware v430 (Version 00)
    What’s new in PowerLogic ION8650 firmware V4.31.1 (Version 00)
    DLMS/COSEM and ION technology (Version 04)
    Date 7/2/19
    Size 147.4 KB
    CAD
    Date
    Size
    Add to My Documents
    8650_SOCKET_ASSEMBLY (Version 1.0)
    Date 4/25/18
    Size 9.7 MB
    Certificate
    Date
    Size
    Add to My Documents
    8650_Russia_Metrology_Certificate (Version 1.0)
    Date 11/21/18
    Size 683.5 KB
    8650_Russia_EAC_Certificate (Version 1.0)
    Date 11/21/18
    Size 659.6 KB
    ION8650-IEC62052-11 IEC62053-22 IEC62053-23 Certificate (Version 1.0)
    ION8650-EAC Certificate (Version 1.0)
    Date 3/26/18
    Size 659.6 KB
    CoC-1901767-01 - Schneider ION8650 - PQI Class A (Version 1.0)
    8650_15-1500 DNV GL_Certificate_Schneider_ION8650_ServerEd2_Certificate (Version 1.0)
    ION8650-IEC61000-4-30 Class A Certificate (Version 1.0)
    ION8650-IEC61850 Certificate (Version 1.0)
    Date 3/26/18
    Size 1.5 MB
    Instruction Sheet
    Date
    Size
    Add to My Documents
    Outage notifications on the PowerLogic ION8650 - EN (Version 00)
    PowerLogic ION8650 socket meter installation guide - EN-FR-ES (Version 02)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    REACh Declaration
    Date
    Size
    Add to My Documents
    Technical leaflet
    Date
    Size
    Add to My Documents
    ION8650 Technical Datasheet - Web Version (Version 1.2)
    ION8650 Technical Datasheet - Print Version (Version 1.2)
    ION8650 Technical Datasheet US Web Version (Version 1.0)
    ION8650 Technical Datasheet US Print Version (Version 1.0)
    Firmware - Released
    Date
    Size
    Add to My Documents
    ION8650 004.031.001 Firmware (Version 1.0)
    Date 6/12/19
    Size 3.5 MB
    Date 6/12/19
    Size 3.5 MB
    Date 6/12/19
    Size 3.5 MB
    Date 6/12/19
    Size 94.5 KB
    Date 6/12/19
    Size 1,009.5 KB
    Date 6/12/19
    Size 1,000.7 KB
    Date 6/12/19
    Size 976.3 KB
    Date 6/12/19
    Size 967.4 KB
    Date 6/12/19
    Size 644.3 KB
    Date 6/12/19
    Size 644.4 KB
    ION8650 004.021.000 Firmware (Version 1.0)
    Date 3/15/18
    Size 4.9 MB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.