USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

power base - TeSys U - 12 A - no connections control

Show more characteristics >
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price*
    275.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys U
    device short name
    LUB
    product or component type
    Non reversing power base
    device application
    Motor
    poles description
    3P
    suitability for isolation
    Yes
    [Ith] conventional free air thermal current
    12 A
    utilisation category
    AC-41
    AC-43
    AC-44
    [Uc] control circuit voltage
    110...220 V DC
    110...240 V AC 50/60 Hz
    24 V AC 50/60 Hz
    24 V DC
    48 V AC 50/60 Hz
    48...72 V DC
    Complementary
    auxiliary contact composition
    1 NO + 1 NC
    auxiliary contacts type
    Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1
    Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1
    System Voltage
    230 V
    440 V
    500 V
    690 V
    network frequency
    40...60 Hz
    [Ie] rated operational current
    12 A at <= 440 V
    12 A at 500 V
    9 A at 690 V
    [Ics] rated service breaking capacity
    10 kA 500 V
    4 kA 690 V
    50 kA 230 V
    50 kA 440 V
    typical current consumption
    130 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    140 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    150 mA at 24 V DC I maximum while closing with LUCM
    280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
    35 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
    35 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
    35 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
    35 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
    60 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
    70 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
    70 mA at 24 V DC I rms sealed with LUCM
    safety reliability level
    B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    operating time
    35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit
    50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit
    60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit
    70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit
    75 ms closing with LUCM control circuit
    mechanical durability
    15000000 cycles
    operating rate
    60 cyc/mn
    [Ui] rated insulation voltage
    600 V conforming to CSA C22.2 No 14
    600 V conforming to UL 508
    690 V conforming to IEC 60947-1 3
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947-6-2
    safe separation of circuit
    400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N
    400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
    connections - terminals
    Power circuit: screw clamp terminals 2 cable 0...0.01 in² (1.5...6 mm²) - cable stiffness: flexible - without cable end
    Power circuit: screw clamp terminals 1 cable 0...0.02 in² (1...10 mm²) - cable stiffness: rigid - without cable end
    Power circuit: screw clamp terminals 1 cable 0...0.01 in² (1...6 mm²) - cable stiffness: flexible - with cable end
    Power circuit: screw clamp terminals 1 cable 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - without cable end
    Power circuit: screw clamp terminals 2 cable 0...0.01 in² (1...6 mm²) - cable stiffness: flexible - with cable end
    Power circuit: screw clamp terminals 2 cable 0...0.01 in² (1...6 mm²) - cable stiffness: rigid - without cable end
    Control circuit: without connection
    tightening torque
    Control circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) flat
    Control circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) Philips no 1
    Power circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) flat
    Power circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) Philips No 2
    width
    1.77 in (45 mm)
    height
    5.71 in (145 mm)
    depth
    4.96 in (126 mm)
    product weight
    1.91 lb(US) (0.865 kg)
    Environment
    heat dissipation
    2 W control circuit with LUCA, LUCB, LUCC, LUCD
    1.7 W control circuit with LUCM
    immunity to microbreaks
    3 ms
    immunity to voltage dips
    70 % 500 ms conforming to IEC 61000-4-11
    product certifications
    ABS
    ASEFA
    ATEX
    BV
    CCC
    CSA
    DNV
    GL
    GOST
    LROS (Lloyds register of shipping)
    UL
    standards
    CSA C22.2 No 14 type E
    EN 60947-6-2
    IEC 60947-6-2
    UL 508 type E with phase barrier
    IP degree of protection
    IP20 front panel and wired terminals conforming to IEC 60947-1
    IP20 other faces conforming to IEC 60947-1
    IP40 front panel outside connection zone conforming to IEC 60947-1
    protective treatment
    TH conforming to IEC 60068
    ambient air temperature for operation
    -13...140 °F (-25...60 °C) with LUCM
    -13...158 °F (-25...70 °C) with LUCA, LUCB, LUCC, LUCD
    ambient air temperature for storage
    -40...185 °F (-40...85 °C)
    fire resistance
    1202 °F (650 °C) conforming to IEC 60695-2-12
    1760 °F (960 °C) parts supporting live components conforming to IEC 60695-2-12
    operating altitude
    6561.68 ft (2000 m)
    shock resistance
    10 gn power poles open conforming to IEC 60068-2-27
    15 gn power poles closed conforming to IEC 60068-2-27
    vibration resistance
    2 gn 5...300 Hz power poles open conforming to IEC 60068-2-27
    4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-27
    resistance to electrostatic discharge
    8 kV level 3 in open air conforming to IEC 61000-4-2
    8 kV level 4 on contact conforming to IEC 61000-4-2
    resistance to radiated fields
    9.14 V/yd (10 V/m) 3 conforming to IEC 61000-4-3
    resistance to fast transients
    2 kV class 3 serial link conforming to IEC 61000-4-4
    4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
    non-dissipating shock wave
    1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2
    1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2
    2 kV common mode 24...240 V AC conforming to IEC 60947-6-2
    2 kV common mode 48...220 V DC conforming to IEC 60947-6-2
    immunity to radioelectric fields
    10 V conforming to IEC 61000-4-6
    Ordering and shipping details
    Category
    22396 - TESYS U - SELF PRTCTD STARTER (LUB)
    Discount Schedule
    I11
    GTIN
    00785901222255
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    1.8100000000000001
    Returnability
    Y
    Country of origin
    FR
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  0709  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    Catalog
    Date
    Size
    Add to My Documents
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.