USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

motor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IP

Show more characteristics >
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price
    905.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys T
    device short name
    LTMR
    product or component type
    Motor controller
    device application
    Equipment monitoring and control
    measurement current
    0.4...8 A
    [Us] rated supply voltage
    24 V DC
    current consumption
    56...127 mA
    supply voltage limits
    20.4...26.24 V DC
    communication port protocol
    Modbus TCP/EtherNet/IP
    bus type
    Ethernet IEEE 802.3 interface, addressing 0...159, transmission rate 10...100 Mbit/s, RJ45 with 2 shielded twisted pairs
    Complementary
    [Ui] rated insulation voltage
    690 V conforming to CSA C22.2 No 14
    690 V conforming to EN/IEC 60947-1
    690 V conforming to UL 508
    [Uimp] rated impulse withstand voltage
    6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
    0.8 kV communication circuit conforming to EN/IEC 60947-4-1
    0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
    short-circuit withstand
    100 kA conforming to EN/IEC 60947-4-1
    associated fuse rating
    0.5 A gG control circuit
    4 A gG output
    protection type
    Earth-leakage protection
    Reverse polarity protection
    Phase unbalance
    Overload (long time)
    Phase failure
    Overload
    Load fluctuation
    Thermal overload protection
    Thermal protection
    Power factor variation
    Locked rotor
    network and machine diagnosis type
    Phase fault and earth fault trip counters
    Trip context information
    Fault recording
    Remaining operating time before overload tripping
    Event recording
    Starting current and time
    Trip history information
    Waiting time after overload tripping
    Motor control command recording
    Running hours counter/operating time
    logic input number
    6
    input current
    7 mA
    current state 0 guaranteed
    Logic input : < 5 V and <= 15 mA for 5 ms
    current state 1 guaranteed
    Logic input : < 15 V and 2...15 mA for 15 ms
    maximum output switching frequency
    2 Hz
    load current
    5 A at 250 V AC logic output
    5 A at 30 V DC logic output
    permissible power
    480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
    30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
    operating rate
    1800 cyc/h
    contacts type and composition
    1 NO + 1 NC fault signal
    3 NO
    metering type
    Phase current I1, I2, I3 RMS
    Average current Iavg
    Imbalance current
    Earth-fault current
    Temperature
    measurement accuracy
    3 % power factor (cos φ > 0.6)
    +/- 30 min/year internal clock
    0,02 temperature
    5...15 % earth fault current internal measurement (for current > 0.1 A)
    1 % current
    1 % voltage (100...830 V)
    5 % active and reactive power
    5 % earth fault current external measurement (< 5 % or 0.01 A)
    overvoltage category
    III
    connection pitch
    0.2 in (5.08 mm)
    connections - terminals
    Connector, 1 flexible cable with cable end 0...0 in² (0.25...2.5 mm²) /AWG 24...AWG 14 control circuit
    Connector, 1 flexible cable without cable end 0...0 in² (0.2...2.5 mm²) /AWG 24...AWG 14 control circuit
    Connector, 1 flexible cable without cable end 0...0 in² (0.25...2.5 mm²) /AWG 24...AWG 14 control circuit
    Connector, 1 solid cable without cable end 0...0 in² (0.2...2.5 mm²) /AWG 24...AWG 14 control circuit
    Connector, 2 flexible cable with cable end 0...0 in² (0.2...1 mm²) /AWG 24...AWG 14 control circuit
    Connector, 2 flexible cable without cable end 0...0 in² (0.2...1.5 mm²) /AWG 24...AWG 14 control circuit
    Connector, 2 flexible cable without cable end 0...0 in² (0.5...1.5 mm²) /AWG 24...AWG 14 control circuit
    Connector, 2 solid cable without cable end 0...0 in² (0.2...1 mm²) /AWG 24...AWG 14 control circuit
    tightening torque
    4.42...5.31 lbf.in (0.5...0.6 N.m), 0.12 in (3 mm) flat screwdriver control circuit
    pollution degree
    3
    electromagnetic compatibility
    ● electrostatic discharge 3 (8 kV air, 6 kV contact), conforming to EN/IEC 61000-4-2
    ● fast transients immunity test other circuits level 3 (2 kV), conforming to EN/IEC 61000-4-4
    ● fast transients immunity test on supply and relay outputs level 4 (4 kV), conforming to EN/IEC 61000-4-4
    ● conducted RF disturbances (10 V), conforming to EN/IEC 61000-4-6
    ● surges common mode (1 kV) control circuit, conforming to EN/IEC 61000-4-5
    ● surges serial mode (1 kV) control circuit, conforming to EN/IEC 61000-4-5
    ● surges common mode (2 kV) communication, conforming to EN/IEC 61000-4-5
    ● radiated RF fields 3 (10 V/m), conforming to EN/IEC 61000-4-3
    ● voltage dips and interruptions immunity test (70 %, 500 ms), conforming to EN/IEC 61000-4-11
    ● surges serial mode (0.5 kV) temperature sensor, conforming to EN/IEC 61000-4-5
    ● surges common mode (1 kV) temperature sensor, conforming to EN/IEC 61000-4-5
    ● surges serial mode (2 kV) relay outputs and supply, conforming to EN/IEC 61000-4-5
    ● surges common mode (4 kV) relay outputs and supply, conforming to EN/IEC 61000-4-5
    width
    3.58 in (91 mm)
    height
    2.4 in (61 mm)
    depth
    4.82 in (122.5 mm)
    product weight
    1.17 lb(US) (0.53 kg)
    web services
    Web server
    compatibility code
    LTMR
    Environment
    standards
    EN 60947-4-1
    UL 508
    IEC 60947-4-1
    CSA C22.2 No 14
    IACS E10
    product certifications
    DNV
    UL
    GL
    RMRoS
    EAC
    C-Tick
    RINA
    CSA
    CCC
    KERI
    NOM
    LROS (Lloyds register of shipping)
    ATEX
    ABS
    BV
    protective treatment
    12 x 24 hour cycles conforming to EN/IEC 60068-2-30
    48 h conforming to EN/IEC 60070-2-11
    TH conforming to EN/IEC 60068
    fire resistance
    1202 °F (650 °C) conforming to EN/IEC 60695-2-12
    1760 °F (960 °C) conforming to UL 94
    ambient air temperature for operation
    -4...140 °F (-20...60 °C)
    ambient air temperature for storage
    -40...176 °F (-40...80 °C)
    operating altitude
    <= 6561.68 ft (2000 m) without derating
    mechanical robustness
    ● shocks half sine wave acceleration (15 Gn for 11 ms) conforming to EN/IEC 60068-2-27
    ● vibrations mounted on symmetrical rail (1 Gn, 5...300 Hz) conforming to EN/IEC 60068-2-6
    ● vibrations plate mounted (4 Gn, 5...300 Hz) conforming to EN/IEC 60068-2-6
    IP degree of protection
    IP20
    Ordering and shipping details
    Category
    22338 - SOLID STATE OVERLOAD RELAYS
    Discount Schedule
    I12
    GTIN
    00785901552598
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    1.24
    Returnability
    Y
    Country of origin
    CN
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  0501  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • French
    Catalog
    Date
    Size
    Add to My Documents
    TeSys catalogue - 2019 - 2020 - chapter B12 Motor management systems TeSys LUTM, T (Version 6.0)
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    Digest 178 Catalog 16: NEMA and Definite Purpose Contactors and Starters (Version 1.0)
    User guide
    Date
    Size
    Add to My Documents
    TeSys Programmer Firmware Update Utility for LTMR & LTMCU (Version 1.0)
    Data Bulletin
    Date
    Size
    Add to My Documents
    Motor Control Solutions for the North American Market (Version 2.0)
    CAD
    Date
    Size
    Add to My Documents
    CAD files for LTMR08EBD: Motor management system TeSys T - Ethernet motor management (Version 1.0)
    Motor management system TeSys T, Ethernet motor management, Ethernet relay (Version 1.0)
    Motor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IP (Version 1.0)
    Motor controller LTMR TeSys T - 24 V DC 8 A for Ethernet TCP/IP (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    CB Certificate TeSys T, LTMR/LTMEV, made in China, according to IEC 60947-4-1 Ed3 (Version 1.0)
    CB Certificate TeSys T, LTMR/LTMEV, made in China, according to IEC 60947-4-1 Ed3 (Version 1.0)
    EDS Files
    Date
    Size
    Add to My Documents
    EDS file for TeSys T EIP (Version 1.0)
    Date 7/2/19
    Size 104.7 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    REACh Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.