Range: TeSys K Miniature Contactors

Reversing contactors

LP5K0610EW3

Schneider Eletric LP5K0610EW3 Picture
Range: TeSys K Miniature Contactors

Reversing contactors

LP5K0610EW3

TeSys K reversing contactor - 3P - AC-3 <= 440 V 6 A - 1 NO - 48 V DC coil

Show more characteristics >
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
  • Price
    202.00 USD
Add to My Products Remove from My Products

  • Main
    range
    TeSys
    product name
    TeSys K
    product or component type
    Reversing contactor
    device short name
    LP5K
    device application
    Control
    contactor application
    Motor control
    utilisation category
    AC-4
    AC-3
    device presentation
    Preassembled with reversing power busbar
    poles description
    3P
    power pole contact composition
    3 NO
    System Voltage
    690 V AC 50/60 Hz power circuit
    <= 690 V AC 50/60 Hz signalling circuit
    [Ie] rated operational current
    6 A at <= 440 V AC AC-3 power circuit
    motor power kW
    3 kW at 440 V AC 50/60 Hz
    3 kW at 500...600 V AC 50/60 Hz
    3 kW at 660...690 V AC 50/60 Hz
    1.5 kW at 220...230 V AC 50/60 Hz
    2.2 kW at 380...415 V AC 50/60 Hz
    3 kW at 480 V AC 50/60 Hz
    control circuit type
    DC low consumption
    [Uc] control circuit voltage
    48 V DC
    auxiliary contact composition
    1 NO
    [Uimp] rated impulse withstand voltage
    8 kV
    overvoltage category
    III
    [Ith] conventional free air thermal current
    20 A at <= 122 °F (50 °C) power circuit
    10 A at <= 122 °F (50 °C) signalling circuit
    Irms rated making capacity
    110 A AC power circuit conforming to NF C 63-110
    110 A AC power circuit conforming to IEC 60947
    110 A AC signalling circuit conforming to IEC 60947
    rated breaking capacity
    110 A at 415 V conforming to IEC 60947
    110 A at 440 V conforming to IEC 60947
    80 A at 500 V conforming to IEC 60947
    110 A at 220...230 V conforming to IEC 60947
    110 A at 380...400 V conforming to IEC 60947
    70 A at 660...690 V conforming to IEC 60947
    [Icw] rated short-time withstand current
    20 A <= 50 °C >= 15 min power circuit
    90 A <= 122 °F (50 °C) 1 s power circuit
    85 A <= 122 °F (50 °C) 5 s power circuit
    80 A <= 122 °F (50 °C) 10 s power circuit
    60 A <= 122 °F (50 °C) 30 s power circuit
    45 A <= 122 °F (50 °C) 1 min power circuit
    40 A <= 122 °F (50 °C) 3 min power circuit
    80 A 1 s signalling circuit
    90 A 500 ms signalling circuit
    110 A 100 ms signalling circuit
    associated fuse rating
    25 A gG at <= 440 V power circuit
    25 A aM power circuit
    10 A gG signalling circuit conforming to IEC 60947
    10 A gG signalling circuit conforming to VDE 0660
    average impedance
    3 mOhm at 50 Hz - Ith 20 A power circuit
    [Ui] rated insulation voltage
    690 V signalling circuit conforming to IEC 60947-4-1
    690 V signalling circuit conforming to IEC 60947-5-1
    600 V signalling circuit conforming to UL 508
    600 V power circuit conforming to CSA C22.2 No 14
    600 V signalling circuit conforming to CSA C22.2 No 14
    690 V power circuit conforming to IEC 60947-4-1
    600 V power circuit conforming to UL 508
    electrical durability
    1.3 Mcycles 6 A AC-3 at Ue <= 440 V
    interlocking type
    Mechanical
    mounting support
    Rail
    Plate
    standards
    BS 5424
    VDE 0660
    NF C 63-110
    IEC 60947
    product certifications
    UL
    CSA
    connections - terminals
    Screw clamp terminals 1 cable(s) 0...0.01 in² (1.5...4 mm²) - cable stiffness: solid
    Screw clamp terminals 1 cable(s) 0...0.01 in² (0.75...4 mm²) - cable stiffness: flexible - without cable end
    Screw clamp terminals 1 cable(s) 0...0 in² (0.34...2.5 mm²) - cable stiffness: flexible - with cable end
    Screw clamp terminals 2 cable(s) 0...0.01 in² (1.5...4 mm²) - cable stiffness: solid
    Screw clamp terminals 2 cable(s) 0...0.01 in² (0.75...4 mm²) - cable stiffness: flexible - without cable end
    Screw clamp terminals 2 cable(s) 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable end
    tightening torque
    11.5 lbf.in (1.3 N.m) - on screw clamp terminals - with screwdriver Philips No 2
    11.5 lbf.in (1.3 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
    operating time
    10...20 ms coil de-energisation and NO opening
    30...40 ms coil energisation and NO closing
    safety reliability level
    B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    mechanical durability
    5 Mcycles
    operating rate
    3600 cyc/h
    Complementary
    coil technology
    Built-in bidirectional peak limiting diode suppressor
    control circuit voltage limits
    0.7...1.30 Uc at <= 122 °F (50 °C) operational
    0.1...0.7 Uc at <= 122 °F (50 °C) drop-out
    inrush power in W
    1.8 W at 68 °F (20 °C)
    hold-in power consumption in W
    1.8 W at 68 °F (20 °C)
    heat dissipation
    1.8 W
    auxiliary contacts type
    Type instantaneous 1 NO
    minimum switching current
    5 mA signalling circuit
    minimum switching voltage
    17 V signalling circuit
    non overlap distance
    0.02 in (0.5 mm)
    insulation resistance
    > 10 MOhm signalling circuit
    Environment
    IP degree of protection
    IP20 conforming to VDE 0106
    protective treatment
    TC conforming to IEC 60068
    TC conforming to DIN 50016
    ambient air temperature for operation
    -13...122 °F (-25...50 °C)
    ambient air temperature for storage
    -58...176 °F (-50...80 °C)
    operating altitude
    6561.68 ft (2000 m) without derating in temperature
    flame retardance
    V1 conforming to UL 94
    Requirement 2 conforming to NF F 16-101
    Requirement 2 conforming to NF F 16-102
    mechanical robustness
    Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27
    Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27
    Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6
    Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
    Shocks contactor opened, on X axis 10 Gn for 11 ms IEC 60068-2-27
    Shocks contactor opened, on Y axis 6 Gn for 11 ms IEC 60068-2-27
    Shocks contactor closed, on X axis 15 Gn for 11 ms IEC 60068-2-27
    Shocks contactor closed, on Y axis 10 Gn for 11 ms IEC 60068-2-27
    height
    2.28 in (58 mm)
    width
    3.54 in (90 mm)
    depth
    2.24 in (57 mm)
    product weight
    1.08 lb(US) (0.49 kg)
    Ordering and shipping details
    Category
    22322 - CTR,K-LINE,DC,OPEN,REV
    Discount Schedule
    I12
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    1.0800000000000001
    Returnability
    N
    Country of origin
    FR
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    California proposition 65
    WARNING: This product can expose you to chemicals including:
    - - - - - - - Substance 1
    Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer.
    - - - - - - - More information
    For more information go to www.p65warnings.ca.gov
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    Catalog
    Date
    Size
    Add to My Documents
    Date 10/8/18
    Size 102.7 MB
    CAD
    Date
    Size
    Add to My Documents
    REVERSING CONTACTOR
    Date 12/19/17
    Size 586.9 KB
    Date 12/19/17
    Size 952.5 KB
    Certificate
    Date
    Size
    Add to My Documents
    Date 7/14/18
    Size 747.3 KB
    Instruction Sheet
    Date
    Size
    Add to My Documents
    Date 6/21/18
    Size 605.9 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.