compact base - 42 + 4 I/O - 24 V DC supply - 2 slots for PCI

Show more characteristics >
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
  • Price
    2,396.96 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Modicon LMC058
    product or component type
    Motion controller
    product specific application
    -
    discrete I/O number
    42
    battery type
    3 V CR2477M lithium battery
    Complementary
    discrete input number
    10 fast input
    12 input
    4 regular input
    discrete input logic
    Sink fast input
    Sink regular input
    Source input
    discrete input voltage
    24 V
    discrete input voltage type
    DC
    analogue input number
    4
    analogue input type
    Current 0...20 mA
    Current 4...20 mA
    Voltage +/- 10 V
    analogue input resolution
    12 bits
    voltage state 1 guaranteed
    >= 15 V fast input
    >= 15 V fast output
    >= 15 V regular input
    voltage state 0 guaranteed
    <= 5 V fast input
    <= 5 V fast output
    <= 5 V regular input
    discrete input current
    4 mA fast input
    4 mA regular input
    input impedance
    6 kOhm fast input
    6 kOhm regular input
    configurable filtering time
    0 ms fast input/regular input and fast output
    1.5 ms fast input/regular input and fast output
    12 ms fast input/regular input and fast output
    4 ms fast input/regular input and fast output
    anti bounce filtering
    2 µs...4 ms configurable fast input/regular input and fast output
    cable distance between devices
    30 m[Space ]for fast input
    insulation
    Between channels and internal logic at 500 V AC
    Non-insulated between channels
    discrete output number
    12 output
    4 fast output
    discrete output logic
    Source
    discrete output voltage
    24 V DC
    output voltage limits
    19.2...28.8 V
    discrete output current
    4 mA fast output
    [Us] rated supply voltage
    24 V DC embedded expert modules power
    supply voltage limits
    20.4...28.8 V
    [In] rated current
    0.04 A embedded expert modules power
    0.3 A main supply
    10 A I/O power segment
    peak current
    < 100 kA (duration= <= 70 s) for main supply
    <= 25 kA (duration= <= 500 s) for I/O power segment
    <= 50 kA (duration= <= 150 s) for embedded expert modules power
    1.2 A (duration= > 70 s) for main supply
    power consumption in W
    <= 14.14 W
    execution time per instruction
    22 ns : Boolean
    memory type
    128 MB flash memory
    64 MB RAM memory
    realtime clock
    Without any user calibration < 30 s/month at 77 °F (25 °C)
    With user calibration <= 6 s/month
    data backed up
    Variables of type retain and retain persistent with battery
    battery life
    1.5 yr
    integrated connection type
    1 CAN port with male SUB-D 9; protocol: CANmotion bus or CANopen with master method
    1 CAN port with male SUB-D 9; protocol: CANopen with master method
    1 encoder with female SUB-D 15
    1 isolated serial link with female RJ45; protocol: Ethernet Modbus TCP/IP with slave method; physical interface: 10BASE-T/100BASE-TX
    1 isolated serial link with female RJ45; protocol: Modbus with master/slave method; transmission frame: RTU/ASCII or character mode ASCII; physical interface: RS232/RS485; transmission rate: 300...115200 bps
    1 isolated serial link with mini B USB; transmission rate: 480 Mbit/s
    1 isolated serial link with USB type A; transmission rate: 480 Mbit/s
    2 free slots PCI
    transmission rate
    10 kbit/s with 16404.2 ft (5000 m) bus; protocol: CANopen
    1000 kbit/s with 13.12 ft (4 m) bus; protocol: CANopen
    125 kbit/s with 1640.42 ft (500 m) bus; protocol: CANopen
    20 kbit/s with 8202.1 ft (2500 m) bus; protocol: CANopen
    250 kbit/s with 820.21 ft (250 m) bus; protocol: CANopen
    50 kbit/s with 3280.84 ft (1000 m) bus; protocol: CANopen
    500 kbit/s with 328.08 ft (100 m) bus; protocol: CANopen
    800 kbit/s with 82.02 ft (25 m) bus; protocol: CANopen
    counting input number
    8 at 200 kHz
    local signalling
    1 LED green/red CAN1 STS
    1 LED green/yellow MBS COM
    1 LED per channel APP0
    1 LED red APP1
    1 LED CAN0 STS
    marking
    CE
    mounting support
    Symmetrical DIN rail
    width
    9.35 in (237.5 mm)
    height
    3.9 in (99 mm)
    depth
    3.35 in (85 mm)
    product weight
    1.7 lb(US) (0.77 kg)
    Environment
    standards
    CSA C22.2 No 213
    IEC 61131-2
    CSA C22.2 No 142
    UL 508
    product certifications
    CSA
    C-Tick
    cULus
    GOST-R
    ambient air temperature for operation
    32...122 °F (0...50 °C) vertical installation
    32...131 °F (0...55 °C) without horizontal installation
    32...140 °F (0...60 °C) with horizontal installation
    ambient air temperature for storage
    -13...158 °F (-25...70 °C)
    relative humidity
    5...95 % without condensation
    IP degree of protection
    IP20 conforming to IEC 61131-2
    pollution degree
    2 conforming to IEC 60664
    operating altitude
    0...6561.68 ft (0...2000 m)
    storage altitude
    0...9842.52 ft (0...3000 m)
    vibration resistance
    1 gn at 8.4...150 Hz with DIN rail mounting
    3.5 mm at 5...8.4 Hz with DIN rail mounting
    shock resistance
    15 gn 11 ms
    electromagnetic compatibility
    Conducted and radiated emissions conforming to CISPR 11
    Conducted RF disturbances conforming to EN/IEC 61000-4-6
    Electrostatic discharge immunity test (test level: 8 kV) - on contact conforming to EN/IEC 61000-4-2
    Electrostatic discharge immunity test (test level: 4 kV) - on air conforming to EN/IEC 61000-4-2
    Susceptibility to electromagnetic fields (test level: 1 V/m) - 2...2.7 GHz conforming to EN/IEC 61000-4-3
    Susceptibility to electromagnetic fields (test level: 10 V/m) - 80...2000 MHz conforming to EN/IEC 61000-4-3
    Electrical fast transient/burst immunity test (test level: 1 kV) - I/O conforming to EN/IEC 61000-4-4
    Electrical fast transient/burst immunity test (test level: 1 kV) - shielded cable conforming to EN/IEC 61000-4-4
    Electrical fast transient/burst immunity test (test level: 2 kV) - power lines conforming to EN/IEC 61000-4-4
    Surge immunity test (test level: 0.5 kV) - differential mode conforming to EN/IEC 61000-4-5
    Surge immunity test (test level: 1 kV) - common mode conforming to EN/IEC 61000-4-5
    disturbance radiated/conducted
    CISPR 11
    Ordering and shipping details
    Category
    18352 - NON PACDRIVE MOTION CONTROLLER
    Discount Schedule
    PC52
    GTIN
    00785901981923
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    2.1099999999999999
    Returnability
    N
    Country of origin
    AT
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    California proposition 65
    WARNING: This product can expose you to chemicals including:
    - - - - - - - Substance 1
    Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm.
    - - - - - - - More information
    For more information go to www.p65warnings.ca.gov
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    CAD
    Date
    Size
    Add to My Documents
    CAD for LMC058LF424: compact base - 42 + 4 I/O - 24 V DC supply - 2 slots for PCI (Version 1.0)
    Declaration of conformity
    Date
    Size
    Add to My Documents
    Modicon DoC M258 LMC058 TM5 (Version 1.4)
    Date 5/3/18
    Size 1.4 MB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 4/16/19
    Size 195.3 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 4/16/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Controller
    Dimensions



  • Connections and Schema

    TM5 System Wiring Recommendations
    Wire Sizes to Use with Removable Spring Terminal Blocks



    External Power Supplies
    Wiring Diagram of the Controller Power Distribution Module


    (1)
    Internal electronics
    (2)
    24 Vdc I/O power segment integrated into the bus bases
    (3)
    PS1/PS2: External isolated SELV power supply 24 Vdc
    (4)
    External fuse, Type T slow-blow, 3 A 250 V
    (5)
    External fuse, Type T slow-blow, 2 A 250 V
    (6)
    External fuse, Type T slow-blow, 10 A max., 250 V