USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region
Schneider Eletric LF4P07D Picture
Discontinued

Schneider Eletric LF4P07D Picture
Discontinued

TeSys LF - enclosed DOL reversing starter - 1.6...2.5 A

Show more characteristics >
LF4P07D  has not been replaced. Please contact your customer care center for more information.
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys LF
    device short name
    LF4P
    product or component type
    Enclosed DOL reversing starter
    device application
    AS interface
    device composition
    Reversing contactor
    Circuit-breaker
    AS interface module
    utilisation category
    AC-3
    network type
    AC
    [Uc] control circuit voltage
    24 V AC circuit at 50/60 Hz
    thermal protection adjustment range
    1.6...2.5 A
    control type
    Rotary handle protection control - OFF - Trip - ON
    Selector switch 3 positions start/stop/start - 1 - 0 - 2
    Complementary
    motor power kW
    0.37 kW at 220/230 V - AC at 50/60 Hz
    0.75 kW at 400/415 V - AC at 50/60 Hz
    network frequency
    50/60 Hz
    System Voltage
    415 V - AC at 50/60 Hz power circuit
    250 V - AC at 50/60 Hz output control relay
    30 V - DC output control relay
    [Uimp] rated impulse withstand voltage
    6 kV for power circuit conforming to IEC 60947-1
    2.5 kV for 24 V conforming to IEC 60947-1
    2.5 kV for sensor conforming to IEC 60947-1
    2.5 kV for AS-Interface conforming to IEC 60947-1
    insulation resistance
    > 1000 mOhm between output and communication
    insulation
    1500 V between output and ground
    1500 V between output and internal logic
    Between input and communication
    [Ui] rated insulation voltage
    415 V AC at 50/60 Hz conforming to IEC 60947
    [Ithe] conventional enclosed thermal current
    5 A for output control relay at 104 °F (40 °C)
    protection type
    Inductive overvoltage
    Phase failure
    Short-circuit protection (magnetic)
    Thermal protection
    breaking capacity
    100 kA at 230/240 V conforming to IEC 60947-2
    100 kA at 400/415 V conforming to IEC 60947-2
    mechanical durability
    Circuit breaker: 0.1 Mcycles
    Contactor: 30 Mcycles
    electrical durability
    Circuit breaker: 0.1 Mcycles
    Contactor: 0.8 Mcycles - AC-3 - 8.5 A
    Relay: 0.1 Mcycles - 24 V with 6 cyc/mn - AC-12 - 5 A
    Relay: 1 Mcycles - 24 V with 15 cyc/mn - AC-12 - 1 A
    Relay: 0.5 Mcycles - 24 V with 15 cyc/mn - AC-14 - 1 A
    Relay: 1 Mcycles - 24 V with 15 cyc/mn - AC-14 - 0.5 A
    Relay: 5 Mcycles - 24 V with 30 cyc/mn - AC-14 - 0.25 A
    Relay: 0.1 Mcycles - 24 V with 6 cyc/mn - DC-12 - 5 A
    Relay: 0.2 Mcycles - 24 V with 6 cyc/mn - DC-12 - 2 A
    Relay: 0.5 Mcycles - 24 V with 15 cyc/mn - DC-3 - 1 A
    Relay: >= 1 Mcycles - 24 V with 30 cyc/mn - DC-3 - 0.25 A
    current consumption
    20 mA for communication bus during operation
    60 mA for communication bus sensor
    0 mA at 24 V for supply circuit de-energisation
    30 mA at 24 V for supply circuit maintained mode
    110 mA at 24 V for supply circuit inrush
    20 mA for output relay
    local signalling
    Product status by 3 LEDs
    Input/output status by LED
    number of inputs
    2 M12
    nominal input value
    19...30 V 50 mA - DC
    input description
    Status D0: forward stop - bit value 0
    Status D1: reverse stop - bit value 0
    Status D2: disable relay - bit value 0
    Status D3: unused - bit value 0
    Status D0: forward start - bit value 1
    Status D1: reverse start - bit value 1
    Status D2: enable relay - bit value 1
    Status D3: unused - bit value 1
    input type
    Resistive
    sensor compatibility
    2 or 3-wire PNP
    output description
    Command D0: not ready - bit value 0
    Command D1: stopped - bit value 0
    Command D2: sensor 1 missing - bit value 0
    Command D3: sensor 2 missing - bit value 0
    Command D0: ready - bit value 1
    Command D1: started - bit value 1
    Command D2: sensor 1 present - bit value 1
    Command D3: sensor 2 present - bit value 1
    response time
    Output control relay: <= 10 ms during closing
    Output control relay: <= 15 ms during opening
    contacts type and composition
    1 C/O
    AS-interface profile
    7DFF - standard
    cable gland type
    Supply circuit: Pg 16 - 0.39...0.59 in (10...15 mm)
    Power circuit: Pg 16 - 0.39...0.59 in (10...15 mm)
    Output control relay: Pg 13 - 0.39...0.59 in (10...15 mm)
    Output control relay: Pg 16 - 0.39...0.59 in (10...15 mm)
    connections - terminals
    Power circuit : screw clamp terminals - flexible without cable end
    Output control relay : screw clamp terminals - rigid
    Output control relay : screw clamp terminals - flexible without cable end
    Supply circuit : screw clamp terminals - rigid
    Supply circuit : screw clamp terminals - flexible with cable end
    Power circuit : screw clamp terminals - flexible with cable end
    Supply circuit : screw clamp terminals - flexible without cable end
    Output control relay : screw clamp terminals - flexible with cable end
    Power circuit : screw clamp terminals - rigid
    tightening torque
    Supply circuit: 15.04 lbf.in (1.7 N.m) - with screwdriver flat Ø 5.5 mm
    Power circuit: 7.08 lbf.in (0.8 N.m) - with screwdriver flat Ø 5.5 mm
    Output control relay: 6.19 lbf.in (0.7 N.m) - with screwdriver flat Ø 3.5 mm
    width
    6.89 in (175 mm)
    height
    7.68 in (195 mm)
    depth
    6.89 in (175 mm)
    product weight
    3.53 lb(US) (1.6 kg)
    Environment
    electromagnetic compatibility
    Electrostatic discharge 8 kV level 3 - in air - conforming to EN/IEC 61000-4-2
    Electrostatic discharge 4 kV level 2 - in indirect mode - conforming to EN/IEC 61000-4-2
    Electrical fast transient/burst immunity test 2 kV level 3 conforming to EN/IEC 61000-4-4
    Surge immunity test 4 kV level 4 - power, line to ground - conforming to IEC 61000-4-5
    Surge immunity test 2 kV level 4 - power, line to line - conforming to EN/IEC 61000-4-5
    Surge immunity test 2 kV level 2 - control circuit, line to ground - conforming to IEC 61000-4-5
    Surge immunity test 500 V level 2 - control circuit, line to line - conforming to EN/IEC 61000-4-5
    Conducted RF disturbances 10 V/m conforming to IEC 61000-4-6
    Conducted RF disturbances 10 V/m conforming to ENV 50141
    Radiated radio-frequency electromagnetic field immunity test 10 V/m conforming to IEC 61000-4-3
    Radiated radio-frequency electromagnetic field immunity test 10 V/m conforming to ENV 50204
    Radiated radio-frequency electromagnetic field immunity test 10 V/m conforming to ENV 50140
    Disturbing field emission class B conforming to ENV 55011
    Disturbing field emission class B conforming to CISPR 11
    mechanical robustness
    Shocks: 10 Gn during contactor open conforming to IEC 60068-2-27
    Shocks: 15 gn during contactor closed conforming to IEC 60068-2-27
    Vibrations: 2 Gn during contactor open conforming to IEC 60068-2-6
    Vibrations: 4 gn during contactor closed conforming to IEC 60068-2-6
    IP degree of protection
    IP54 conforming to IEC 60529
    protective treatment
    TC
    fire resistance
    1760 °F (960 °C) conforming to IEC 60695-2-1
    operating altitude
    6561.68 ft (2000 m)
    standards
    EN 60204-1
    EN 60439-1
    EN 60947-1
    IEC 60204-1
    IEC 60439-1
    IEC 60947-1
    material
    Bottom: polycarbonate + 20 % FG - black
    Top: polycarbonate + 20 % FG - white: RAL 9001
    ambient air temperature for operation
    23...104 °F (-5...40 °C) conforming to IEC 61439-1
    ambient air temperature for storage
    -40...176 °F (-40...80 °C) conforming to IEC 61439-1
    Ordering and shipping details
    Category
    18325 - SERIPLEX SOFTWARE&CABLES DISC SPX2
    Discount Schedule
    SPX2
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    4.1799999999999997
    Returnability
    N
    Country of origin
    FR
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    Compliant  - since  0925  -  Schneider Electric declaration of conformity
    Schneider Electric declaration of conformity
    REACh
    Reference contains SVHC above the threshold  -  Go to CaP for more details
    Go to CaP for more details
    Product environmental profile
    Available
    Product end of life instructions
    Available
    California proposition 65
    WARNING: This product can expose you to chemicals including:
    - - - - - - - Substance 1
    Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer.
    - - - - - - - Substance 2
    Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm.
    - - - - - - - More information
    For more information go to www.p65warnings.ca.gov
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Date 4/3/19
    Size 195.3 KB
    REACh Declaration
    Date
    Size
    Add to My Documents
    Date 4/3/19
    Size 195.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.