USA
Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region
Schneider Eletric LC2K0901B7TQ Picture
Discontinued

Schneider Eletric LC2K0901B7TQ Picture
Discontinued

reversing contactor TeSys LC2-K - 3 poles - AC-3 440V 9 A - coil 24 V AC

Show more characteristics >
LC2K0901B7TQ  has not been replaced. Please contact your customer care center for more information.
  • Price
    167.00 USD
Add to My Products Remove from My Products

  • Main
    range of product
    TeSys K
    product or component type
    Reversing contactor
    device short name
    LC2K
    contactor application
    Motor control
    Resistive load
    utilisation category
    AC-1
    AC-3
    control circuit type
    AC
    coil type
    AC 50/60 Hz
    poles description
    3P
    pole contact composition
    3 NO
    [Ie] rated operational current
    20 A (<= 122 °F (50 °C)) AC network AC-1 power circuit
    9 A AC network AC-3 power circuit
    motor power kW
    4 kW at 380...415 V AC 50/60 Hz
    2.2 kW at 220...230 V AC 50/60 Hz
    4 kW at 440/500 V AC 50/60 Hz
    4 kW at 660/690 V AC 50/60 Hz
    motor power hp
    2 hp at 200/208 V AC 60 Hz conforming to CSA
    2 hp at 200/208 V AC 60 Hz conforming to UL
    3 hp at 230/240 V AC 60 Hz conforming to CSA
    3 hp at 230/240 V AC 60 Hz conforming to UL
    5 hp at 460/480 V AC 60 Hz conforming to CSA
    5 hp at 460/480 V AC 60 Hz conforming to UL
    5 hp at 575/600 V AC 60 Hz conforming to CSA
    5 hp at 575/600 V AC 60 Hz conforming to UL
    auxiliary contact composition
    1 NC
    [Uc] control circuit voltage
    24 V AC 50/60 Hz
    connections - terminals
    Power circuit: screw clamp terminal 1 cable 0 in² (2.5 mm²) - cable stiffness: flexible - with cable end
    Power circuit: screw clamp terminal 2 cable 0.01 in² (4 mm²) - cable stiffness: flexible - without cable end
    Power circuit: screw clamp terminal 1 cable 0 in² (1.5 mm²) - cable stiffness: solid
    Power circuit: screw clamp terminal 2 cable 0.01 in² (4 mm²) - cable stiffness: solid
    Control circuit: screw clamp terminal 1 cable 0 in² (1.5 mm²) - cable stiffness: solid
    Control circuit: screw clamp terminal 2 cable 0.01 in² (4 mm²) - cable stiffness: solid
    Power circuit: spring terminal 1 cable 0 in² (0.75 mm²) - cable stiffness: solid
    Power circuit: spring terminal 1 cable 0 in² (1.5 mm²) - cable stiffness: solid
    Control circuit: spring terminal 1 cable 0 in² (0.75 mm²) - cable stiffness: solid
    Control circuit: spring terminal 1 cable 0 in² (1.5 mm²) - cable stiffness: solid
    Power circuit: screw clamp terminal 1 cable 0 in² (0.75 mm²) - cable stiffness: flexible - without cable end
    Power circuit: screw clamp terminal 1 cable 0 in² (0.34 mm²) - cable stiffness: flexible - with cable end
    Power circuit: screw clamp terminal 1 cable 0 in² (1.5 mm²) - cable stiffness: flexible - with cable end
    Control circuit: screw clamp terminal 1 cable 0 in² (0.75 mm²) - cable stiffness: flexible - without cable end
    Control circuit: screw clamp terminal 2 cable 0.01 in² (4 mm²) - cable stiffness: flexible - without cable end
    Control circuit: screw clamp terminal 1 cable 0 in² (0.34 mm²) - cable stiffness: flexible - with cable end
    Control circuit: screw clamp terminal 1 cable 0 in² (1.5 mm²) - cable stiffness: flexible - with cable end
    Control circuit: screw clamp terminal 1 cable 0 in² (2.5 mm²) - cable stiffness: flexible - with cable end
    Power circuit: spring terminal 1 cable 0 in² (0.75 mm²) - cable stiffness: flexible - without cable end
    Power circuit: spring terminal 1 cable 0 in² (1.5 mm²) - cable stiffness: flexible - without cable end
    Control circuit: spring terminal 1 cable 0 in² (0.75 mm²) - cable stiffness: flexible - without cable end
    Control circuit: spring terminal 1 cable 0 in² (1.5 mm²) - cable stiffness: flexible - without cable end
    Power circuit: Faston connectors 2witdh:0.11 in (2.8 mm) - cable stiffness: clip
    Power circuit: Faston connectors 1witdh:0.25 in (6.35 mm) - cable stiffness: clip
    Control circuit: Faston connectors 2witdh:0.11 in (2.8 mm) - cable stiffness: clip
    Control circuit: Faston connectors 1witdh:0.25 in (6.35 mm) - cable stiffness: clip
    quantity per set
    Set of 10
    Complementary
    assembly style
    Ready assembled
    coil technology
    Without built-in bidirectional peak limiting diode suppressor
    interlocking type
    Mechanical
    control circuit voltage limits
    >= 0.20 Uc at <= 122 °F (50 °C) drop-out 50/60 Hz
    0.8...1.15 Uc at <= 122 °F (50 °C) operational 50/60 Hz
    [Ui] rated insulation voltage
    600 V control circuit conforming to CSA C22.2 No 14
    600 V power circuit certifications UL 508 conforming to CSA C22.2 No 14
    690 V control circuit conforming to BS 5424
    690 V control circuit conforming to IEC 60947
    690 V power circuit conforming to BS 5424
    690 V power circuit conforming to IEC 60947
    690 V power circuit conforming to NF C 20-040
    750 V control circuit conforming to VDE 0110 group C
    750 V power circuit conforming to VDE 0110 group C
    [Uimp] rated impulse withstand voltage
    8 kV
    mounting support
    Plate
    Rail
    flame retardance
    Class C2 conforming to NF F 16-101
    Class C2 conforming to NF F 16-102
    V1 conforming to UL 94
    tightening torque
    Power circuit: - on screwclamp terminal - cable 0...0 in² (0.34...1.5 mm²) - with screwdriver Philips No 2 M6 flat
    Power circuit: - on screwclamp terminal - cable 0...0 in² (0.34...2.5 mm²) - with screwdriver Philips No 2 M6 flat
    Power circuit: - on screwclamp terminal - cable 0...0.01 in² (0.75...4 mm²) - with screwdriver Philips No 2 M6 flat
    Power circuit: - on screwclamp terminal - cable 0...0.01 in² (1.5...4 mm²) - with screwdriver Philips No 2 M6 flat
    System Voltage
    <= 690 V AC <= 400 Hz power circuit
    [Ith] conventional free air thermal current
    10 A at <= 122 °F (50 °C) control circuit
    20 A at <= 122 °F (50 °C) power circuit
    Irms rated making capacity
    110 A at 690 V AC control circuit conforming to IEC 60947
    110 A at 690 V AC power circuit conforming to IEC 60947
    110 A at 690 V AC power circuit conforming to NF C 63-110
    rated breaking capacity
    110 A at 220...230 V power circuit conforming to IEC 60947
    110 A at 220...230 V power circuit conforming to NF C 63-110
    110 A at 380...400 V power circuit conforming to IEC 60947
    110 A at 380...400 V power circuit conforming to NF C 63-110
    110 A at 415 V power circuit conforming to IEC 60947
    110 A at 415 V power circuit conforming to NF C 63-110
    110 A at 440 V power circuit conforming to IEC 60947
    110 A at 440 V power circuit conforming to NF C 63-110
    70 A at 660...690 V power circuit conforming to IEC 60947
    70 A at 660...690 V power circuit conforming to NF C 63-110
    80 A at 500 V power circuit conforming to IEC 60947
    80 A at 500 V power circuit conforming to NF C 63-110
    associated fuse rating
    10 A gG control circuit conforming to IEC 60947
    10 A gG control circuit conforming to VDE 0660
    25 A gG at <= 440 V power circuit
    average impedance
    3 mOhm at 50 Hz - Ith 20 A power circuit
    inrush power in VA
    30 VA at 68 °F (20 °C)
    hold-in power consumption in VA
    4.5 VA at 68 °F (20 °C) 50/60 Hz
    operating time
    10...20 ms coil de-energisation and NO opening
    15...25 ms coil de-energisation and NC opening
    5...15 ms coil energisation and NC opening
    10...20 ms coil energisation and NO closing
    safety reliability level
    B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    mechanical durability
    5000000 cycles
    operating rate
    3600 cyc/h
    minimum switching current
    5 mA control circuit
    minimum switching voltage
    17 V control circuit
    insulation resistance
    > 10 MOhm control circuit
    height
    2.28 in (58 mm)
    width
    3.54 in (90 mm)
    depth
    2.24 in (57 mm)
    product weight
    0.86 lb(US) (0.39 kg)
    Environment
    standards
    BS 5424
    IEC 60947
    NF C 63-110
    VDE 0660
    product certifications
    CSA
    GOST
    UL
    IP degree of protection
    IP2x conforming to VDE 0106
    protective treatment
    TC conforming to IEC 60068
    ambient air temperature for operation
    -13...122 °F (-25...50 °C)
    ambient air temperature for storage
    -58...176 °F (-50...80 °C)
    operating altitude
    6561.68 ft (2000 m) without derating
    fire resistance
    1562 °F (850 °C) conforming to IEC 60695-2-1
    shock resistance
    10 gn contactor closed
    6 gn contactor opened
    vibration resistance
    2 gn 5...300 Hz contactor opened
    4 gn 5...300 Hz contactor closed
    heat dissipation
    1.3 W at 50/60 Hz control circuit
    Ordering and shipping details
    Category
    22327 - CTR,K-LINE,AC,OPEN,REV
    Discount Schedule
    I12
    Nbr. of units in pkg.
    15
    Package weight(Lbs)
    5.0000000000000003E-2
    Returnability
    N
    Country of origin
    FR
    Offer Sustainability
    RoHS (date code: YYWW)
    Product end of life instructions
    Need no specific recycling operations
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    CAD
    Date
    Size
    Add to My Documents
    REVERSING CONTACTOR (Version 1.0)
    Date 7/9/18
    Size 946.8 KB
    Date 7/9/18
    Size 589.9 KB
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.