TeSys D reversing contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 48 V DC coil

Show more characteristics >
LC2D40A3ED  has not been replaced. Please contact your customer care center for more information.
  • Price
    692.00 USD
Add to My Products Remove from My Products

  • Main
    range
    TeSys
    product name
    TeSys D
    product or component type
    Reversing contactor
    device short name
    LC2D
    contactor application
    Motor control
    Resistive load
    utilisation category
    AC-1
    AC-3
    device presentation
    Preassembled with reversing power busbar
    poles description
    3P
    pole contact composition
    3 NO
    System Voltage
    <= 300 V DC power circuit
    <= 690 V AC 25...400 Hz power circuit
    [Ie] rated operational current
    40 A (<= 140 °F (60 °C)) at <= 440 V AC AC-3 power circuit
    60 A (<= 140 °F (60 °C)) at <= 440 V AC AC-1 power circuit
    motor power kW
    11 kW at 220...230 V AC 50/60 Hz
    22 kW at 500 V AC 50/60 Hz
    30 kW at 660...690 V AC 50/60 Hz
    18.5 kW at 380...400 V AC 50/60 Hz
    22 kW at 415...440 V AC 50/60 Hz
    motor power hp
    5 hp at 230/240 V AC 50/60 Hz 1 phase motors
    10 hp at 230/240 V AC 50/60 Hz 3 phases motors
    30 hp at 575/600 V AC 50/60 Hz 3 phases motors
    3 hp at 115 V AC 50/60 Hz 1 phase motors
    10 hp at 200/208 V AC 50/60 Hz 3 phases motors
    30 hp at 460/480 V AC 50/60 Hz 3 phases motors
    control circuit type
    DC standard
    [Uc] control circuit voltage
    48 V DC
    auxiliary contact composition
    1 NO + 1 NC
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947
    overvoltage category
    III
    [Ith] conventional free air thermal current
    60 A at <= 140 °F (60 °C) power circuit
    10 A at <= 140 °F (60 °C) signalling circuit
    Irms rated making capacity
    800 A at 440 V power circuit conforming to IEC 60947
    140 A AC signalling circuit conforming to IEC 60947-5-1
    250 A DC signalling circuit conforming to IEC 60947-5-1
    rated breaking capacity
    800 A at 440 V power circuit conforming to IEC 60947
    [Icw] rated short-time withstand current
    100 A 1 s signalling circuit
    120 A 500 ms signalling circuit
    140 A 100 ms signalling circuit
    320 A <= 104 °F (40 °C) 10 s power circuit
    720 A <= 104 °F (40 °C) 1 s power circuit
    72 A <= 104 °F (40 °C) 10 min power circuit
    165 A <= 104 °F (40 °C) 1 min power circuit
    associated fuse rating
    80 A gG at <= 690 V coordination type 1 power circuit
    80 A gG at <= 690 V coordination type 2 power circuit
    10 A gG signalling circuit conforming to IEC 60947-5-1
    average impedance
    At 50 Hz - Ith 60 A for power circuit
    [Ui] rated insulation voltage
    600 V power circuit certifications CSA
    600 V power circuit certifications UL
    690 V power circuit conforming to IEC 60947-4-1
    690 V signalling circuit conforming to IEC 60947-1
    600 V signalling circuit certifications CSA
    600 V signalling circuit certifications UL
    electrical durability
    1.5 Mcycles 40 A AC-3 at Ue <= 440 V
    1.4 Mcycles 60 A AC-1 at Ue <= 440 V
    power dissipation per pole
    5.4 W AC-1
    2.4 W AC-3
    protective cover
    With
    interlocking type
    Mechanical
    mounting support
    Plate
    Rail
    standards
    CSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    product certifications
    CCC
    CSA
    GOST
    UL
    connections - terminals
    Power circuit: EverLink BTR screw connectors 1 cable(s) 0...0.05 in² (1...35 mm²) - cable stiffness: flexible - without cable end
    Power circuit: EverLink BTR screw connectors 1 cable(s) 0...0.05 in² (1...35 mm²) - cable stiffness: flexible - with cable end
    Power circuit: EverLink BTR screw connectors 1 cable(s) 0...0.05 in² (1...35 mm²) - cable stiffness: solid - without cable end
    Power circuit: EverLink BTR screw connectors 2 cable(s) 0...0.04 in² (1...25 mm²) - cable stiffness: flexible - without cable end
    Power circuit: EverLink BTR screw connectors 2 cable(s) 0...0.04 in² (1...25 mm²) - cable stiffness: flexible - with cable end
    Power circuit: EverLink BTR screw connectors 2 cable(s) 0...0.04 in² (1...25 mm²) - cable stiffness: solid - without cable end
    Control circuit: spring terminals 1 cable(s) 0...0 in² (0.75...2.5 mm²) - cable stiffness: flexible - without cable end
    Control circuit: spring terminals 2 cable(s) 0...0 in² (0.75...2.5 mm²) - cable stiffness: flexible - without cable end
    tightening torque
    Power circuit: 70.8 lbf.in (8 N.m) - on EverLink BTR screw connectors - cable 0.04...0.05 in² (25...35 mm²) hexagonal 0.16 in (4 mm)
    Power circuit : 5 N.m - on EverLink BTR screw connectors - cable 1...25 mm² hexagonal 4 mm
    operating time
    16...24 ms opening
    42.5...57.5 ms closing
    safety reliability level
    B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    mechanical durability
    10 Mcycles
    operating rate
    3600 cyc/h at <= 140 °F (60 °C)
    Complementary
    coil technology
    Built-in bidirectional peak limiting diode suppressor
    control circuit voltage limits
    0.1...0.3 Uc drop-out at 140 °F (60 °C), DC
    0.75...1.25 Uc operational at 60 °C, DC
    time constant
    34 ms
    inrush power in W
    19 W at 68 °F (20 °C)
    hold-in power consumption in W
    7.4 W at 68 °F (20 °C)
    auxiliary contacts type
    Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
    Type mirror contact (1 NC) conforming to IEC 60947-4-1
    signalling circuit frequency
    25...400 Hz
    minimum switching current
    5 mA signalling circuit
    minimum switching voltage
    17 V Signalling circuit
    non-overlap time
    1.5 ms on de-energisation (between NC and NO contact)
    1.5 ms on energisation (between NC and NO contact)
    insulation resistance
    > 10 MOhm signalling circuit
    Environment
    IP degree of protection
    IP20 front face conforming to IEC 60529
    protective treatment
    TH conforming to IEC 60068-2-30
    pollution degree
    3
    ambient air temperature for operation
    23...140 °F (-5...60 °C)
    ambient air temperature for storage
    -76...176 °F (-60...80 °C)
    permissible ambient air temperature around the device
    -40...158 °F (-40...70 °C) at Uc
    operating altitude
    9842.52 ft (3000 m) without derating in temperature
    fire resistance
    1562 °F (850 °C) conforming to IEC 60695-2-1
    flame retardance
    V1 conforming to UL 94
    mechanical robustness
    Vibrations contactor open 2 Gn, 5...300 Hz
    Vibrations contactor closed 4 Gn, 5...300 Hz
    Shocks contactor open 10 Gn for 11 ms
    Shocks contactor closed 15 Gn for 11 ms
    height
    4.8 in (122 mm)
    width
    4.69 in (119 mm)
    depth
    4.72 in (120 mm)
    product weight
    4.45 lb(US) (2.02 kg)
    Ordering and shipping details
    Category
    22346 - CTR,D-LINE,OPEN,REVERSING-NEW
    Discount Schedule
    I12
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    4.6200000000000001
    Returnability
    N
    Country of origin
    FR
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • French
    CAD
    Date
    Size
    Add to My Documents
    3P EVLK REVERS CONT 40A
    Date 6/21/18
    Size 515.7 KB
    Date 6/21/18
    Size 752.3 KB
    Instruction Sheet
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.