TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil

Show more characteristics >
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price
    6,993.00 USD
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range
    TeSys
    product name
    TeSys F
    product or component type
    Contactor
    device short name
    LC1F
    contactor application
    Resistive load
    Motor control
    utilisation category
    AC-1
    AC-3
    AC-4
    poles description
    3P
    power pole contact composition
    3 NO
    System Voltage
    <= 1000 V AC 50/60 Hz
    <= 460 V DC
    [Ie] rated operational current
    1600 A (<= 104 °F (40 °C)) at <= 440 V AC AC-1
    780 A (<= 131 °F (55 °C)) at <= 440 V AC AC-3
    motor power kW
    400 kW at 380...400 V AC 50/60 Hz AC-3
    425 kW at 415 V AC 50/60 Hz AC-3
    450 kW at 1000 V AC 50/60 Hz AC-3
    425 kW at 440 V AC 50/60 Hz AC-3
    450 kW at 500 V AC 50/60 Hz AC-3
    110 kW at 400 V AC 50/60 Hz AC-4
    220 kW at 220...240 V AC 50/60 Hz AC-3
    475 kW at 660...690 V AC 50/60 Hz AC-3
    Complementary
    [Uimp] rated impulse withstand voltage
    8 kV
    overvoltage category
    III
    [Ith] conventional free air thermal current
    1600 A at <= 104 °F (40 °C)
    Irms rated making capacity
    7800 A AC conforming to IEC 60947-4-1
    rated breaking capacity
    6240 A conforming to IEC 60947-4-1
    [Icw] rated short-time withstand current
    6250 A <= 104 °F (40 °C) 10 s
    5600 A <= 104 °F (40 °C) 30 s
    4600 A <= 104 °F (40 °C) 1 min
    3000 A <= 104 °F (40 °C) 3 min
    2200 A <= 104 °F (40 °C) 10 min
    associated fuse rating
    800 A aM at <= 440 V
    1600 A gG at <= 440 V
    average impedance
    0.1 mOhm at 50 Hz - Ith 1600 A
    [Ui] rated insulation voltage
    1000 V conforming to IEC 60947-4-1
    1500 V conforming to VDE 0110 group C
    power dissipation per pole
    250 W AC-1
    60 W AC-3
    mounting support
    Plate
    standards
    IEC 60947-4-1
    EN 60947-4-1
    EN 60947-1
    IEC 60947-1
    JIS C8201-4-1
    product certifications
    DNV
    CCC
    BV
    RINA
    UL
    LROS (Lloyds register of shipping)
    CB
    ABS
    connections - terminals
    Power circuit: bolted connection
    Power circuit: bar 2 x (100 x 5 mm)
    tightening torque
    Power circuit: 513.27 lbf.in (58 N.m)
    Environment
    IP degree of protection
    IP20 front face with shrouds (ordered separately) conforming to IEC 60529
    IP20 front face with shrouds (ordered separately) conforming to VDE 0106
    protective treatment
    TH
    ambient air temperature for operation
    23...131 °F (-5...55 °C)
    ambient air temperature for storage
    -76...176 °F (-60...80 °C)
    permissible ambient air temperature around the device
    -40...158 °F (-40...70 °C)
    operating altitude
    9842.52 ft (3000 m) without derating
    mechanical robustness
    Vibrations resistance contactor open 2.5 Gn, 5...300 Hz
    Vibrations resistance contactor closed 5.5 Gn, 5...300 Hz
    Shocks resistance contactor closed 15 Gn for 1/2 sine wave (11 ms)
    Shocks resistance contactor open 5 Gn for 1/2 sine wave (11 ms)
    height
    17.09 in (434 mm)
    width
    27.64 in (702 mm)
    depth
    10.04 in (255 mm)
    product weight
    105.82 lb(US) (48 kg)
    Ordering and shipping details
    Category
    22336 - CTR,F-LINE,AC,OPEN,NONREV
    Discount Schedule
    I12
    GTIN
    00785901132905
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    94.600000000000009
    Returnability
    Y
    Country of origin
    CZ
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    California proposition 65
    WARNING: This product can expose you to chemicals including:
    - - - - - - - Substance 1
    Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm.
    - - - - - - - More information
    For more information go to www.p65warnings.ca.gov
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • German
    • Chinese
    Catalog
    Date
    Size
    Add to My Documents
    Digest 178 Catalog 18: Contactors and Starters-IEC (Version 1.0)
    Control Panel Technical Guide - How to quickly design optimized contactor assemblies (Version 1.1)
    Tesys catalogue 2019 - 2020 Motor control and protection components (Version 9.2)
    TeSys catalogue - 2019 - 2020 - chapter B9 high power contactors TeSys F,V, FG, CR1F (Version 7.0)
    TeSys catalogue - 2019 - 2020 - chapter A6 - Circuit breaker + contactor coordination tables and design guidelines (Version 6.1)
    Data Bulletin
    Date
    Size
    Add to My Documents
    Motor Control Solutions for the North American Market (Version 2.0)
    CAD
    Date
    Size
    Add to My Documents
    LC1F780 contactor 3 poles. (Version 1.1)
    Date 10/1/11
    Size 231.1 KB
    Date 10/1/11
    Size 12.5 KB
    Date 10/1/11
    Size 677.9 KB
    Date 10/1/11
    Size 63.7 KB
    CAD file (on TraceParts) for LC1F780: TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 780 A - without coil (Version 2.0)
    TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 780 A (Version 1.0)
    LC1F780 contactor 3 poles and 4 poles. (Version 1.1)
    Certificate
    Date
    Size
    Add to My Documents
    CB Certificate - LC1F630-780 - Czech republic - according to IEC 60947-4-1 (Version 1.0)
    Instruction Sheet
    Date
    Size
    Add to My Documents
    LC1 F115...F1250 Contactors (Version 05)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    REACh Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.