USA

Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 220 V AC 50/60 Hz coil

Show more characteristics >
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price
    479.00 USD
Add to My Products Remove from My Products

  • Main
    range
    TeSys
    product name
    TeSys D
    product or component type
    Contactor
    device short name
    LC1D
    contactor application
    Motor control
    Resistive load
    utilisation category
    AC-1
    AC-3
    AC-4
    poles description
    3P
    power pole contact composition
    3 NO
    System Voltage
    <= 300 V DC power circuit
    <= 1000 V AC 25...400 Hz power circuit
    [Ie] rated operational current
    200 A (<= 140 °F (60 °C)) at <= 440 V AC AC-1 power circuit
    115 A (<= 140 °F (60 °C)) at <= 440 V AC AC-3 power circuit
    motor power kW
    55 kW at 380...400 V AC 50/60 Hz AC-3
    75 kW at 500 V AC 50/60 Hz AC-3
    80 kW at 660...690 V AC 50/60 Hz AC-3
    30 kW at 220...230 V AC 50/60 Hz AC-3
    59 kW at 415...440 V AC 50/60 Hz AC-3
    65 kW at 1000 V AC 50/60 Hz AC-3
    18.5 kW at 400 V AC 50/60 Hz AC-4
    motor power HP (UL / CSA)
    30 hp at 200/208 V AC 50/60 Hz 3 phases motors
    40 hp at 230/240 V AC 50/60 Hz 3 phases motors
    75 hp at 460/480 V AC 50/60 Hz 3 phases motors
    100 hp at 575/600 V AC 50/60 Hz 3 phases motors
    control circuit type
    AC 50/60 Hz
    [Uc] control circuit voltage
    220 V AC 50/60 Hz
    auxiliary contact composition
    1 NO + 1 NC
    [Uimp] rated impulse withstand voltage
    Conforming to IEC 60947
    overvoltage category
    III
    [Ith] conventional free air thermal current
    200 A at <= 140 °F (60 °C) power circuit
    Irms rated making capacity
    1260 A at 440 V power circuit conforming to IEC 60947
    140 A AC signalling circuit conforming to IEC 60947-5-1
    250 A DC signalling circuit conforming to IEC 60947-5-1
    rated breaking capacity
    1100 A at 440 V power circuit conforming to IEC 60947
    [Icw] rated short-time withstand current
    1100 A <= 104 °F (40 °C) 1 s power circuit
    100 A 1 s signalling circuit
    120 A 500 ms signalling circuit
    140 A 100 ms signalling circuit
    250 A <= 104 °F (40 °C) 10 min power circuit
    550 A <= 104 °F (40 °C) 1 min power circuit
    950 A <= 104 °F (40 °C) 10 s power circuit
    associated fuse rating
    200 A gG at <= 690 V coordination type 2 power circuit
    250 A gG at <= 690 V coordination type 1 power circuit
    10 A gG signalling circuit
    average impedance
    0.6 mOhm at 50 Hz - Ith 200 A power circuit
    [Ui] rated insulation voltage
    1000 V power circuit conforming to IEC 60947-4-1
    600 V power circuit certifications CSA
    600 V power circuit certifications UL
    690 V signalling circuit conforming to IEC 60947-1
    600 V signalling circuit certifications CSA
    600 V signalling circuit certifications UL
    electrical durability
    0.8 Mcycles 200 A AC-1 at Ue <= 440 V
    0.95 Mcycles 115 A AC-3 at Ue <= 440 V
    power dissipation per pole
    24 W AC-1
    7.9 W AC-3
    safety cover
    With
    mounting support
    Plate
    Rail
    standards
    CSA C22.2 No 14
    EN 60947-4-1
    EN 60947-5-1
    IEC 60947-4-1
    IEC 60947-5-1
    UL 508
    product certifications
    BV
    CCC
    CSA
    DNV
    GL
    GOST
    LROS (Lloyds register of shipping)
    RINA
    UL
    connections - terminals
    Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - without cable end
    Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end
    Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: solid - without cable end
    Control circuit: screw clamp terminals 1 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end
    Control circuit: screw clamp terminals 1 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - without cable end
    Control circuit: screw clamp terminals 1 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: solid - without cable end
    Power circuit: connector 1 cable(s) 0.02...0.19 in² (10...120 mm²) - cable stiffness: flexible - without cable end
    Power circuit: connector 2 cable(s) 0.02...0.08 in² (10...50 mm²) - cable stiffness: flexible - without cable end
    Power circuit: connector 1 cable(s) 0.02...0.19 in² (10...120 mm²) - cable stiffness: flexible - with cable end
    Power circuit: connector 2 cable(s) 0.02...0.08 in² (10...50 mm²) - cable stiffness: flexible - with cable end
    Power circuit: connector 1 cable(s) 0.02...0.19 in² (10...120 mm²) - cable stiffness: solid - without cable end
    Power circuit: connector 2 cable(s) 0.02...0.08 in² (10...50 mm²) - cable stiffness: solid - without cable end
    tightening torque
    Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
    Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver Philips No 2
    Power circuit: 106.19 lbf.in (12 N.m) - on connector hexagonal 0.16 in (4 mm)
    operating time
    6...20 ms opening
    20...50 ms closing
    safety reliability level
    B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
    B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    mechanical durability
    8 Mcycles
    operating rate
    2400 cyc/h at <= 140 °F (60 °C)
    Complementary
    coil technology
    Built-in bidirectional peak limiting diode suppressor
    control circuit voltage limits
    0.3...0.5 Uc drop-out at 131 °F (55 °C), AC 50/60 Hz
    0.8...1.15 Uc operational at 131 °F (55 °C), AC 50/60 Hz
    inrush power in VA
    280...350 VA at 68 °F (20 °C) (cos ϕ 0.8) 60 Hz
    280...350 VA at 68 °F (20 °C) (cos ϕ 0.8) 50 Hz
    hold-in power consumption in VA
    2...18 VA at 68 °F (20 °C) (cos ϕ 0.3) 60 Hz
    2...18 VA at 68 °F (20 °C) (cos ϕ 0.3) 50 Hz
    heat dissipation
    3...8 W at 50/60 Hz
    auxiliary contacts type
    Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
    Type mirror contact (1 NC) conforming to IEC 60947-4-1
    signalling circuit frequency
    25...400 Hz
    minimum switching current
    5 mA signalling circuit
    minimum switching voltage
    17 V signalling circuit
    non-overlap time
    1.5 ms on de-energisation (between NC and NO contact)
    1.5 ms on energisation (between NC and NO contact)
    insulation resistance
    > 10 MOhm signalling circuit
    Environment
    IP degree of protection
    IP20 front face conforming to IEC 60529
    protective treatment
    TH conforming to IEC 60068-2-30
    pollution degree
    3
    ambient air temperature for operation
    23...140 °F (-5...60 °C)
    ambient air temperature for storage
    -76...176 °F (-60...80 °C)
    permissible ambient air temperature around the device
    -40...158 °F (-40...70 °C) at Uc
    operating altitude
    9842.52 ft (3000 m) without derating
    fire resistance
    1562 °F (850 °C) conforming to IEC 60695-2-1
    flame retardance
    V1 conforming to UL 94
    mechanical robustness
    Vibrations contactor open 2 Gn, 5...300 Hz
    Vibrations contactor closed 4 Gn, 5...300 Hz
    Shocks contactor closed 15 Gn for 11 ms
    Shocks contactor open 6 Gn for 11 ms
    height
    6.22 in (158 mm)
    width
    4.72 in (120 mm)
    depth
    5.35 in (136 mm)
    product weight
    5.51 lb(US) (2.5 kg)
    Ordering and shipping details
    Category
    22345 - CTR,D-LINE,OPEN,NONREV-NEW
    Discount Schedule
    I12
    GTIN
    00785901696889
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    5.46
    Returnability
    Y
    Country of origin
    CZ
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
    California proposition 65
    WARNING: This product can expose you to chemicals including:
    - - - - - - - Substance 1
    Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer.
    - - - - - - - More information
    For more information go to www.p65warnings.ca.gov
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • Portuguese
    • Russian
    • French
    • Italian
    • German
    • Chinese
    Catalog
    Date
    Size
    Add to My Documents
    TeSys catalogue - 2019 - chapter B8 contactors TeSys SK,K, D, SKGC, GC, GY,GF (Version 6.0)
    Data Bulletin
    Date
    Size
    Add to My Documents
    Motor Control Solutions for the North American Market (Version 2.0)
    CAD
    Date
    Size
    Add to My Documents
    IEC Contactor, 115-150a, 3 Pole, D-Line (TESYS) (Version 1.2)
    CONTACTOR (Version 1.0)
    Date 6/25/18
    Size 733.3 KB
    Date 6/25/18
    Size 573.1 KB
    Brochure
    Date
    Size
    Add to My Documents
    Innovative energy-efficient solutions to power containerships owned by Hamburg Sud (Version 1.0)
    Certificate
    Date
    Size
    Add to My Documents
    CCC TeSys D - LC.D115-150, Czech Republic (Version 1.0)
    CB TeSys D - LC1D115-150 (Version 1.0)
    Date 11/10/17
    Size 263.8 KB
    Instruction Sheet
    Date
    Size
    Add to My Documents
    LC1/LC2 D115 D150 Contactors / Reversing contactors (Version 12)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    PEP - TeSys D LC1D115 to D150 contactors (Version 2.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions


    (1)
    Minimum electrical clearance

    LC1

    D115 and D150 (3-pole)

    a

    120

    b1

    with LA4 DA2

    174

    with LA4 DF, DT

    185

    with LA4 DM, DL

    188

    with LA4 DW

    188

    c

    without cover or add-on blocks

    132

    with cover, without add-on blocks

    136

    c1

    with LAD N or C (2 or 4 contacts)

    150

    c2

    with LA6 DK20

    155

    c3

    with LAD T, R, S

    168

    with LAD T, R, S and sealing cover

    172


  • Connections and Schema