Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

    Schneider Eletric LC1D09B7 Picture

    Range: TeSys D Contactors

    Contactors

    LC1D09B7

    Schneider Eletric LC1D09B7 Picture
    Range: TeSys D Contactors

    Contactors

    LC1D09B7

    TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC coil

    Show more characteristics >
    • Product availability
      Stock - Normally stocked in distribution facility
    • Price
      94.00 USD
    Add to My Favorites Remove from My Favorites

    • Main
      range
      TeSys
      product name
      TeSys D
      product or component type
      Contactor
      device short name
      LC1D
      contactor application
      Resistive load
      Motor control
      utilisation category
      AC-1
      AC-4
      AC-3
      poles description
      3P
      pole contact composition
      3 NO
      System Voltage
      <= 300 V DC power circuit
      <= 690 V AC 25...400 Hz power circuit
      [Ie] rated operational current
      25 A (<= 140 °F (60 °C)) at <= 440 V AC AC-1 power circuit
      9 A (<= 140 °F (60 °C)) at <= 440 V AC AC-3 power circuit
      motor power kW
      2.2 kW at 400 V AC 50/60 Hz AC-4
      2.2 kW at 220...230 V AC 50/60 Hz AC-3
      4 kW at 380...400 V AC 50/60 Hz AC-3
      5.5 kW at 500 V AC 50/60 Hz AC-3
      5.5 kW at 660...690 V AC 50/60 Hz AC-3
      4 kW at 415...440 V AC 50/60 Hz AC-3
      motor power hp
      0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
      1 hp at 230/240 V AC 50/60 Hz 1 phase motors
      2 hp at 200/208 V AC 50/60 Hz 3 phases motors
      2 hp at 230/240 V AC 50/60 Hz 3 phases motors
      5 hp at 460/480 V AC 50/60 Hz 3 phases motors
      7.5 hp at 575/600 V AC 50/60 Hz 3 phases motors
      control circuit type
      AC 50/60 Hz
      [Uc] control circuit voltage
      24 V AC 50/60 Hz
      auxiliary contact composition
      1 NO + 1 NC
      [Uimp] rated impulse withstand voltage
      6 kV conforming to IEC 60947
      overvoltage category
      III
      [Ith] conventional free air thermal current
      25 A at <= 140 °F (60 °C) power circuit
      10 A at <= 140 °F (60 °C) signalling circuit
      Irms rated making capacity
      250 A at 440 V power circuit conforming to IEC 60947
      140 A AC signalling circuit conforming to IEC 60947-5-1
      250 A DC signalling circuit conforming to IEC 60947-5-1
      rated breaking capacity
      250 A at 440 V power circuit conforming to IEC 60947
      [Icw] rated short-time withstand current
      105 A <= 104 °F (40 °C) 10 s power circuit
      210 A <= 104 °F (40 °C) 1 s power circuit
      30 A <= 104 °F (40 °C) 10 min power circuit
      61 A <= 104 °F (40 °C) 1 min power circuit
      100 A 1 s signalling circuit
      120 A 500 ms signalling circuit
      140 A 100 ms signalling circuit
      associated fuse rating
      20 A gG at <= 690 V coordination type 2 power circuit
      25 A gG at <= 690 V coordination type 1 power circuit
      10 A gG signalling circuit conforming to IEC 60947-5-1
      average impedance
      2.5 mOhm at 50 Hz - Ith 25 A power circuit
      [Ui] rated insulation voltage
      600 V power circuit certifications CSA
      600 V power circuit certifications UL
      690 V power circuit conforming to IEC 60947-4-1
      690 V signalling circuit conforming to IEC 60947-1
      600 V signalling circuit certifications CSA
      600 V signalling circuit certifications UL
      electrical durability
      0.6 Mcycles 25 A AC-1 at Ue <= 440 V
      2 Mcycles 9 A AC-3 at Ue <= 440 V
      power dissipation per pole
      0.2 W AC-3
      1.56 W AC-1
      protective cover
      With
      mounting support
      Rail
      Plate
      standards
      CSA C22.2 No 14
      EN 60947-4-1
      EN 60947-5-1
      IEC 60947-4-1
      IEC 60947-5-1
      UL 508
      product certifications
      CSA
      DNV
      GL
      RINA
      GOST
      BV
      CCC
      LROS (Lloyds register of shipping)
      UL
      connections - terminals
      Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end
      Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end
      Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
      Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
      Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end
      Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
      Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
      Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
      Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
      Power circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end
      Power circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
      Power circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
      tightening torque
      Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
      Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2
      Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
      Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2
      operating time
      4...19 ms opening
      12...22 ms closing
      safety reliability level
      B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
      B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
      mechanical durability
      15 Mcycles
      operating rate
      3600 cyc/h at <= 140 °F (60 °C)
      Complementary
      coil technology
      Without built-in suppressor module
      control circuit voltage limits
      0.3...0.6 Uc drop-out at 140 °F (60 °C), AC 50/60 Hz
      0.8...1.1 Uc operational at 140 °F (60 °C), AC 50 Hz
      0.85...1.1 Uc operational at 140 °F (60 °C), AC 60 Hz
      inrush power in VA
      70 VA at 68 °F (20 °C) (cos ϕ 0.75) 60 Hz
      70 VA at 68 °F (20 °C) (cos ϕ 0.75) 50 Hz
      hold-in power consumption in VA
      7.5 VA at 68 °F (20 °C) (cos ϕ 0.3) 60 Hz
      7 VA at 68 °F (20 °C) (cos ϕ 0.3) 50 Hz
      heat dissipation
      2...3 W at 50/60 Hz
      auxiliary contacts type
      Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
      Type mirror contact (1 NC) conforming to IEC 60947-4-1
      signalling circuit frequency
      25...400 Hz
      minimum switching current
      5 mA signalling circuit
      minimum switching voltage
      17 V signalling circuit
      non-overlap time
      1.5 ms on energisation between NC and NO contact
      1.5 ms on de-energisation between NC and NO contact
      insulation resistance
      > 10 MOhm signalling circuit
      Environment
      IP degree of protection
      IP20 front face conforming to IEC 60529
      protective treatment
      TH conforming to IEC 60068-2-30
      pollution degree
      3
      ambient air temperature for operation
      23...140 °F (-5...60 °C)
      ambient air temperature for storage
      -76...176 °F (-60...80 °C)
      permissible ambient air temperature around the device
      -40...158 °F (-40...70 °C) at Uc
      operating altitude
      9842.52 ft (3000 m) without derating in temperature
      fire resistance
      1562 °F (850 °C) conforming to IEC 60695-2-1
      flame retardance
      V1 conforming to UL 94
      mechanical robustness
      Vibrations contactor open 2 Gn, 5...300 Hz
      Vibrations contactor closed 4 Gn, 5...300 Hz
      Shocks contactor open 10 Gn for 11 ms
      Shocks contactor closed 15 Gn for 11 ms
      height
      3.03 in (77 mm)
      width
      1.77 in (45 mm)
      depth
      3.39 in (86 mm)
      product weight
      0.71 lb(US) (0.32 kg)
      Ordering and shipping details
      Category
      22345 - CTR,D-LINE,OPEN,NONREV-NEW
      Discount Schedule
      I12
      GTIN
      00785901206927
      Nbr. of units in pkg.
      1
      Package weight(Lbs)
      0.77000000000000002
      Returnability
      Y
      Country of origin
      ID
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      RoHS (date code: YYWW)
      Compliant  - since  0627  -  Schneider Electric declaration of conformity Schneider Electric declaration of conformity
      REACh
      Product environmental profile
      Available
      Product end of life instructions
      Available
      Contractual warranty
      Warranty period
      18 months
    • Documents and Downloads

      Language
      • English
      Catalog
      Date
      Size
      Add to My Documents
      Date 8/20/18
      Size 102.7 MB
      Date 8/8/18
      Size 3.4 MB
      Data Bulletin
      Date
      Size
      Add to My Documents
      Date 3/9/18
      Size 1.5 MB
      CAD
      Date
      Size
      Add to My Documents
      IEC Contactor, 9-12A, 3 Pole, D-Line
      IEC Contactor, 9-18a, 3 Pole, D-Line (TESYS)
      CONTACTOR
      Date 3/12/18
      Size 441.6 KB
      Date 3/12/18
      Size 229.9 KB
      Date 3/12/18
      Size 436.5 KB
      Certificate
      Date
      Size
      Add to My Documents
      Date 11/10/17
      Size 2.4 MB
      Instruction Sheet
      Date
      Size
      Add to My Documents
      Date 12/13/17
      Size 87.9 KB
      Handout
      Date
      Size
      Add to My Documents
      Date 10/21/16
      Size 265.6 KB
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
    • Dimensions Drawings

      Dimensions


      (1)
      Including LAD 4BB
      (2)
      Minimum electrical clearance

      LC1

      D09…D18

      D093…D123

      D099…D129

      b

      without add-on blocks

      77

      99

      80

      b1

      with LAD 4BB

      94

      107

      95.5

      with LA4 D●2

      110(1)

      123(1)

      111.5(1)

      with LA4 DF, DT

      119(1)

      132(1)

      120.5(1)

      with LA4 DW, DL

      126(1)

      139(1)

      127.5(1)

      c

      without cover or add-on blocks

      84

      84

      84

      with cover, without add-on blocks

      86

      86

      86

      c1

      with LAD N or C (2 or 4 contacts)

      117

      117

      117

      c2

      with LA6 DK10, LAD 6K10

      129

      129

      129

      c3

      with LAD T, R, S

      137

      137

      137

      with LAD T, R, S and sealing cover

      141

      141

      141

      (1)

      Including LAD 4BB.


    • Connections and Schema

      Wiring



    • Motor Starter BOM

      Our Proposal - Type 1 : Circuit Breaker + Contactor for Motor Power from 0,06 to 4 kW and 415 VAC

      Motor power

      (kW)

      ICU

      (kA)

      Breaker

      Contactor (*)

      0.06

      > 100


      GV2ME02


      LC1D09B7

      0.09

      > 100


      GV2ME03


      LC1D09B7

      0,12 to 0,18

      > 100


      GV2ME04


      LC1D09B7

      0,25 to 0,37

      > 100


      GV2ME05


      LC1D09B7

      0.55

      > 100


      GV2ME06


      LC1D09B7

      0.75

      > 100


      GV2ME07


      LC1D09B7

      1,1 to 1,5

      > 100


      GV2ME08


      LC1D09B7

      2.2

      > 100


      GV2ME10


      LC1D09B7

      3 to 4

      > 100


      GV2ME14


      LC1D09B7

      Non contractual pictures.

      Type 1 coordination requires that in a short-circuit condition, the contactor or starter must not present any danger to personnel or installations and must not be able to resume operation without repair or the replacement of parts.