View all Galaxy VX

Galaxy VX - GVX1250K1000HS

Schneider Eletric GVX1250K1000HS Picture
View all Galaxy VX
Galaxy VX - GVX1250K1000HS

Galaxy VX 1000kVA N+1 Redundant UPS 400V, Start up 5x8

Show more characteristics >
Add to My Products Remove from My Products

  • Overview
    Description
    Highly efficient, scalable, 3-phase power protection with flexible operating modes and ECOnversion™ for large facilities, data centers, and business critical applications.
    Model Name
    Galaxy VX 1000kVA N+1 Redundant UPS 400V, Start up 5x8
    Includes
    Installation guide , Network Management Card , Start-Up Service
    Standard Lead Time
    Special Order - Call for Quoted Lead Times
    Product Distribution
    Afghanistan , Albania , Algeria , Andorra , Angola , Armenia , Australia , Austria , Azerbaijan , Bahrain , Bangladesh , Belarus , Belgium , Benin , Bhutan , Bosnia And Herzegovina , Botswana , Brazil , Brunei Darussalam , Bulgaria , Burkina Faso , Burundi , Cambodia , Cameroon , Canada , Central African Republic , Chad , China , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , Cook Islands , Cote D'Ivoire , Croatia , Cyprus , Czech Republic , Denmark , Djibouti , East Timor , Egypt , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Fiji , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Guadeloupe , Guinea , French Guiana , Hong Kong , Hungary , Iceland , India , Indonesia , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Japan , Jordan , Kazakhstan , Kenya , KOREA, REPUBLIC OF , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Malaysia , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Myanmar , Namibia , Nepal , Netherlands , New Zealand , Niger , Nigeria , Norway , Oman , Pakistan , Papua New Guinea , Philippines , Poland , Portugal , Qatar , Reunion , Romania , Russian Federation , Rwanda , Saudi Arabia , Senegal , Sierra Leone , Singapore , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sri Lanka , Sudan , Suriname , Sweden , Switzerland , Taiwan , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Thailand , Togo , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , United States , Uzbekistan , Viet Nam , Western Sahara , Yemen , Zambia , Zimbabwe
    Output
    Output Power Capacity
    1.0 MW / 1.0 MVA
    Max Configurable Power (Watts)
    1.0 MW / 1.0 MVA
    Nominal Output Voltage
    400 3PH
    Output Frequency (sync to mains)
    50 Hz , 60 Hz
    Other Output Voltages
    380, 415, 440V
    Crest Factor
    3 with THC <5%
    Double Conversion Online
    Waveform Type
    Sine wave
    Output Voltage THD
    < 2% linear load and <3% non-linear load
    Overload Operation
    150% for 1 minute 125% for 10 minutes
    Input
    Nominal Input Voltage
    400 3PH
    Input Frequency
    40 - 70 Hz
    Other Input Voltages
    380 , 415 , 440
    Maximum Input Current
    1702 A
    Maximum Short Circuit Withstand (Icw)
    100.0
    Input Total Harmonic Distortion
    Less than 3% for full load
    Batteries & Runtime
    Battery Type
    No internal battery - uses external battery system
    Nominal Battery Voltage
    480V
    End of Discharge Battery Voltage
    384 Vdc
    Communications & Management
    Available SmartSlot™ Interface Quantity
    2
    Pre-Installed SmartSlot™ Cards
    AP9635
    Control panel
    7" Touch Screen Display
    Audible Alarm
    Audible and visible alarms prioritized by severity
    Physical
    Maximum Height
    77.56 inches (1970.0 mm)
    Maximum Width
    177.17 inches (4500.0 mm)
    Maximum Depth
    35.43 inches (900.0 mm)
    Net Weight
    7716.19 lbs (3500.0 kg)
    Shipping Weight
    10317.64 lbs (4680.0 kg)
    Shipping Height
    84.65 inches (2150.0 mm)
    Shipping Width
    212.2 inches (5390.0 mm)
    Shipping Depth
    41.73 inches (1060.0 mm)
    Color
    White
    Environmental
    Operating Environment
    32 - 104 °F (0 - 40 °C)
    Operating Relative Humidity
    0 - 95% non-condensing %
    Operating Elevation
    0-3333 feet (0-999.9 meters)
    Storage Temperature
    5 - 104 °F (-15 - 40 °C)
    Storage Relative Humidity
    0 - 95% non-condensing %
    Storage Elevation
    0-50000 feet (0-15000 meters)
    Audible noise at 1 meter from surface of unit
    69.500 dB
    Online Thermal Dissipation
    169513.000 BTU/hr
    Protection Class
    IP 20
    Conformance
    Approvals
    C-tick , CE , IEC 62040-1-1 , IEC 62040-2 , IEC 62040-3 , IEC 62040-4 , ISTA 2B , UL 1778 5th edition , cUL Listed
    Standard warranty
    1 year on-site repair or replace with factory authorized Start-Up
    Sustainable Offer Status
    RoHS
    Compliant
    REACH
    REACH: Contains No SVHCs
    Battery Directive
    Compliant
  • Documents and Downloads

    Language
    • English
    User guide
    Date
    Size
    Add to My Documents
    Date 10/25/17
    Size 245.5 KB
    Date 4/12/18
    Size 1.8 MB
    Date 8/9/18
    Size 22.1 MB
    Date 10/24/18
    Size 4.2 MB
    CAD
    Date
    Size
    Add to My Documents
    GVX300-1000KH-WD - Galaxy VX UPS 300-500-625-750-1000kW 400V System Wiring Diagram
    GVX300K1000HS - Galaxy VX UPS 300-500-625-750-1000kVA scalable to 1000kVA N+1, 400V
    Brochure
    Date
    Size
    Add to My Documents
    Date 8/13/18
    Size 1.3 MB
    Specification guide
    Date
    Size
    Add to My Documents
    Certificate
    Date
    Size
    Add to My Documents
    Specification for tender
    Date
    Size
    Add to My Documents
    CSI 2004/1995 Galaxy VX 500kW Expandable to 1500kVA N+1 Internal Redundancy (400V)
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.