View all
TeSys GV7 Manual Starters and Protectors
TeSys GV7 Manual Starters and Protectors - GV7RE150
Thermal-magnetic motor circuit breakers
View all
TeSys GV7 Manual Starters and Protectors
TeSys GV7 Manual Starters and Protectors
-
GV7RE150
Thermal-magnetic motor circuit breakers
TeSys GV7 - circuit breaker - 3P - AC-3 - 90...150 A - thermal-magnetic
Show more characteristics >-
Product availabilityStock - Normally stocked in distribution facility
-
Characteristics
Main range TeSysproduct name TeSys GV7device short name GV7Rproduct or component type Circuit breakerdevice application Motorpoles description 3Pnetwork type ACutilisation category AC-3 conforming to IEC 60947-4-1network frequency 50/60 Hz conforming to IEC 60947-4-1breaking capacity 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-235 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 220/240 V AC 50/60 Hz conforming to IEC 60947-2100 % at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 % at 660/690 V AC 50/60 Hz conforming to IEC 60947-2100 % at 440 V AC 50/60 Hz conforming to IEC 60947-250 %at 500 V AC 50/60 Hz conforming to IEC 60947-2thermal protection adjustment range 90...150 Atrip unit technology Thermal-magneticComplementary mounting mode By screwsBy clipsmounting support RailKit for fixing the switchgearPanel mountingFlushmounting position Verticalmotor power kW 110 kW at 660...690 V AC 50/60 Hz55 kW at 400...415 V AC 50/60 Hz75 kW at 400...415 V AC 50/60 Hz75 kW at 500 V AC 50/60 Hz90 kW at 500 V AC 50/60 Hz90 kW at 660...690 V AC 50/60 Hzcontrol type Rocker leverSystem Voltage 690 V AC 50/60 Hz conforming to IEC 60947-2[Ui] rated insulation voltage 750 V AC 50/60 Hz conforming to IEC 60947-2[Ith] conventional free air thermal current 150 A conforming to IEC 60947-4-1[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2power dissipation per pole 8.7 Wpower dissipation per pole 8.7 Wmechanical durability 40000 cycleselectrical durability 40000 cycles AC-3 at 440 V In/220000 cycles AC-3 at 440 V Inoperating rate 25 cyc/hrated duty Continuous conforming to IEC 60947-4-1connection pitch 1.38 in (35 mm) without spreaders1.77 in (45 mm) with spreadersconnections - terminals BarsCable with lug - external diameter : 10 mmBare cable connectors 1.5...95 mm²Screwtightening torque 10 N.m - on screw - screw M615 N.m - on bare cable connectors- cable 1.5...95 mm²mechanical robustness Shocks 15 Gn for 11 ms conforming to IEC 60068-2-27Vibrations 2.5 Gn, 0...25 Hz conforming to IEC 60068-2-6suitability for isolation Yes conforming to IEC 60947-1phase failure sensitivity Yes conforming to IEC 60947-4-1 § 7-2-1-5-2height 4.92 in (125 mm)width 4.13 in (105 mm)depth 4.37 in (111 mm)product weight 4.45 lb(US) (2.02 kg)Environment standards EN/IEC 60947-2EN/IEC 60947-4-1NF C 79-130VDE 0113NF C 63-120EN/IEC 60947-1NF C 63-650VDE 0660product certifications DNVULprotective treatment TCIP degree of protection IP405 with terminal shrouds conforming to IEC 60529pollution degree 3ambient air temperature for operation -13...158 °F (-25...70 °C)ambient air temperature for storage -67...203 °F (-55...95 °C)fire resistance 1760 °F (960 °C) conforming to IEC 60695-2-1operating altitude 6561.68 ft (2000 m)Ordering and shipping details Category 22366 - MAN STR PROTECTORS-GV1/GV3Discount Schedule I11GTIN 00785901566861Nbr. of units in pkg. 1Package weight(Lbs) 4.3399999999999999Returnability YCountry of origin CNOffer Sustainability RoHS (date code: YYWW) REACh Product environmental profile AvailableCalifornia proposition 65 WARNING: This product can expose you to chemicals including:- - - - - - - Substance 1 Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer.- - - - - - - More information For more information go to www.p65warnings.ca.govContractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
CatalogSizeAdd to My DocumentsGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors (Version 1.0)Digest Catalog 18: IEC Contactors and Starters (Version 1.8)CADSizeAdd to My DocumentsThermal-magnetic circuit-breakers GV7 R with screw clamp terminals, control by rocker lever, from 9 at 110 kW to 400V, from 11 at 132 kW to 500V, from 15 at 200 kW to 660V (Version 1.0)Date 10/1/11Size 1.6 KBDate 10/1/11Size 40.6 KBDate 10/1/11Size 52.8 KBDate 10/1/11Size 3.8 KBThermal-magnetic circuit-breakers GV7 R with screw clamp terminals, control by rocker lever, from 9 at 110 kW to 400V, from 11 at 132 kW to 500V, from 15 at 200 kW to 660V (Version 1.0)Date 4/27/16Size 2.2 KBDate 4/27/16Size 46.8 KBDate 4/27/16Size 69.7 KBDate 4/27/16Size 5.4 KB -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.