processor module M340 - max 1024 discrete + 256 analog I/O - CANOpen

Show more characteristics >
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price
    2,745.00 USD
Add to My Products Remove from My Products

  • Main
    range of product
    Modicon M340 automation platform
    product or component type
    Processor module
    concept
    CANopen
    Transparent Ready
    number of racks
    4
    number of slots
    11
    discrete I/O processor capacity
    1024 I/O multi-rack configuration
    704 I/O single-rack configuration
    analogue I/O processor capacity
    256 I/O multi-rack configuration
    66 I/O single-rack configuration
    number of application specific channel
    36
    Complementary
    control channels
    Programmable loops
    motion control
    Independent axis CANopen
    integrated connection type
    Ethernet TCP/IP RJ45 10/100 Mbit/s 1 twisted pair
    USB port 12 Mbit/s
    CANopen master bus SUB-D 9 20 kbit/s...1 Mbit/s 2 twisted shielded pairs
    communication module processor capacity
    2 Ethernet communication module
    4 AS-Interface module
    embedded communication service
    Bandwidth management, Ethernet TCP/IP
    Data Editor, Ethernet TCP/IP
    Modbus TCP messaging, Ethernet TCP/IP
    Rack Viewer, Ethernet TCP/IP
    SNMP network administrator, Ethernet TCP/IP
    Network management (NMT) CANopen
    Process Data Object (PDO) CANopen
    Service Data Object (SDO) CANopen
    Special functions (SYNC, EMCY, TIME) CANopen
    port Ethernet
    10BASE-T/100BASE-TX
    transmission rate
    1 Mbit/s 0...65.62 ft (0...20 m) 0...1.97 ft (0...0.6 m)
    125 kbit/s 0...1640.42 ft (0...500 m) 0...32.81 ft (0...10 m)
    20 kbit/s 0...8202.1 ft (0...2500 m) 0...984.25 ft (0...300 m)
    250 kbit/s 0...820.21 ft (0...250 m) 0...32.81 ft (0...10 m)
    50 kbit/s 0...3280.84 ft (0...1000 m) 0...393.7 ft (0...120 m)
    500 kbit/s 0...328.08 ft (0...100 m) 0...32.81 ft (0...10 m)
    800 kbit/s 0...131.23 ft (0...40 m) 0...19.69 ft (0...6 m)
    bus type
    CANopen M20 DS 301 V4.02 devices linked by daisy-chaining or tap junctions CSMA/CA
    CANopen M20 DS 303-2 devices linked by daisy-chaining or tap junctions CSMA/CA
    CANopen M20 DS 405 devices linked by daisy-chaining or tap junctions CSMA/CA
    number of slave
    63 CANopen
    number of devices per segment
    16 <= 205 m CANopen
    32 <= 185 m CANopen
    64 <= 160 m CANopen
    memory description
    4096 kB internal RAM
    256 kB internal RAM data
    3584 kB internal RAM program constants and symbols
    Supplied memory card (BMXRMS008MP) activation of standard web server, class B10
    Supplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data
    maximum size of object areas
    256 kB unlocated internal data
    32634 %Mi located internal bits
    default size of object areas
    1024 %MWi internal words located internal data
    256 %KWi constant words located internal data
    512 %Mi located internal bits
    application structure
    1 cyclic/periodic master task
    1 periodic fast task
    64 event tasks
    No auxiliary task
    execution time per instruction
    0.12 µs Boolean
    0.17 µs double-length words
    0.25 µs single-length words
    1.16 µs floating points
    number of instructions per ms
    6.4 Kinst/ms 65 % Boolean + 35 % fixed arithmetic
    8.1 Kinst/ms 100 % Boolean
    system overhead
    0.13 ms fast task
    0.7 ms master task
    current consumption
    135 mA 24 V DC
    supply
    Internal power supply via rack
    marking
    CE
    status LED
    1 LED green activity on Ethernet network (ETH ACT)
    1 LED green integrated machine/installation bus operational (CAN RUN)
    1 LED green processor running (RUN)
    1 LED green status of Ethernet network (ETH STS)
    1 LED red data rate (ETH 100)
    1 LED red I/O module fault (I/O)
    1 LED red integrated machine/installation bus fault (CAN ERR)
    1 LED red memory card fault (CARD ERR)
    1 LED red processor or system fault (ERR)
    1 LED yellow activity on Modbus (SER COM)
    product weight
    0.47 lb(US) (0.215 kg)
    Environment
    ambient air temperature for operation
    32...140 °F (0...60 °C)
    relative humidity
    10...95 % without condensation
    IP degree of protection
    IP20
    protective treatment
    TC
    directives
    2012/19/EU - WEEE directive
    2014/30/EU - electromagnetic compatibility
    2014/35/EU - low voltage directive
    standards
    EN 61000-6-2
    EN 61000-6-4
    EN 61131-2
    EN 61010-2-201
    Ordering and shipping details
    Category
    18160 - MODICON M340
    Discount Schedule
    PC34
    GTIN
    00785901955023
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    0.55000000000000004
    Returnability
    Y
    Country of origin
    FR
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Product end of life instructions
    Available
    California proposition 65
    WARNING: This product can expose you to chemicals including:
    - - - - - - - Substance 1
    Lead and lead compounds which is known to the State of California to cause cancer and birth defects or other reproductive harm.
    - - - - - - - More information
    For more information go to www.p65warnings.ca.gov
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    • French
    Catalog
    Date
    Size
    Add to My Documents
    Catalogue Modicon M340 automation platform - English version 2014/09 (web pdf format) (Version 3.1)
    User guide
    Date
    Size
    Add to My Documents
    Firmware Compatibility Rules - Modicon M580, Modicon Momentum, and Modicon X80 I/O Modules (Version 02)
    Modicon M580 Standalone System Planning Guide for Frequently Used Architectures (Version 09)
    Modicon M580 - RIO Modules, Installation and Configuration Guide (Version 09)
    Modicon M580, Hardware Reference Manual (Version 09)
    Modicon M580 - Módulos RIO, Guía de instalación y configuración (Version 08)
    Plataforma de controladores de Modicon - Ciberseguridad, Manual de referencia (Version 05)
    Modicon Controllers Platform - Cyber Security, Reference Manual (Version 06)
    Modicon M340 - Processors, Setup Manual (Version 13)
    Modicon M580 - Cambio de configuración sobre la marcha, Manual del usuario (Version 06)
    Modicon M580, Hardware Manual de referencia (Version 08)
    Modicon M580 autónomo - Guía de planificación del sistema para arquitecturas utilizadas con más frecuencia (Version 08)
    Modicon M580 - Change Configuration on the Fly. User Guide (Version 07)
    Certificate
    Date
    Size
    Add to My Documents
    HazLoc by CSA - Class I Division 2 - M340_M580_X80 (Version 1.0)
    UL E486184 - NRAQ-NRAQ7 (Version 1.0)
    Date 2/11/19
    Size 395.6 KB
    CSA 225844 - M340_M580_X80 (Version 1.0)
    Date 2/13/19
    Size 242.2 KB
    EAC - M340_M580_X80 (Version 1.0)
    Date 2/11/19
    Size 2.2 MB
    Instruction Sheet
    Date
    Size
    Add to My Documents
    Modicon M340 Modules Firmware Compatibility Rules, Instruction Sheet (Version 00)
    EU RoHS Declaration
    Date
    Size
    Add to My Documents
    Product Environmental Profile
    Date
    Size
    Add to My Documents
    Modicon M340 Modules, Product Environmental Profile (Version 2.0)
    REACh Declaration
    Date
    Size
    Add to My Documents
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Modules Mounted on Racks
    Dimensions


    (1)
    With removable terminal block (cage, screw or spring).
    (2)
    With FCN connector.
    (3)
    On AM1 ED rail: 35 mm wide, 15 mm deep. Only possible with BMXXBP0400/0400H/0600/0600H/0800/0800H rack.

    Rack references

    a in mm

    a in in.

    BMXXBP0400 and BMXXBP0400H

    242.4

    09.54

    BMXXBP0600 and BMXXBP0600H

    307.6

    12.11

    BMXXBP0800 and BMXXBP0800H

    372.8

    14.68

    BMXXBP1200 and BMXXBP1200H

    503.2

    19.81