    • Main
      range of product
      Altivar 71
      product or component type
      Variable speed drive
      product specific application
      Complex, high-power machines
      component name
      ATV71
      motor power kW
      0.37 kWat 200...240 V single phase
      0.75 kW at 200...240 V 3 phases
      motor power hp
      1 hp at 200...240 V 3 phases
      0.5 hpat 200...240 V single phase
      motor cable length
      <= 164.04 ft (50 m) Shielded cable
      <= 328.08 ft (100 m) Unshielded cable
      [Us] rated supply voltage
      200...240 V (- 15...10 %)
      Phase
      3 phases
      Single phase
      line current
      5.3 Afor 240 V 3 phases 0.75 kW / 1 hp
      5.8 Afor 240 V single phase 0.37 kW / 0.5 hp
      6.1 Afor 200 V 3 phases 0.75 kW / 1 hp
      6.9 Afor 200 V single phase 0.37 kW / 0.5 hp
      EMC filter
      Integrated
      assembly style
      With heat sink
      variant
      Without remote graphic terminal
      apparent power
      1.4 kVAat 240 V single phase 0.37 kW / 0.5 hp
      2.2 kVAat 240 V 3 phases 0.75 kW / 1 hp
      prospective line Isc
      <= 5 kA, 3 phases
      <= 5 kA, single phase
      nominal output current
      3 Aat 4 kHz 230 V single phase 0.37 kW / 0.5 hp
      4.8 Aat 4 kHz 230 V 3 phases 0.75 kW / 1 hp
      maximum transient current
      4.5 Afor 60 s single phase 0.37 kW / 0.5 hp
      4.9 Afor 2 s single phase 0.37 kW / 0.5 hp
      7.2 Afor 60 s 3 phases 0.75 kW / 1 hp
      7.9 Afor 2 s 3 phases 0.75 kW / 1 hp
      output frequency
      0.1...599 Hz
      nominal switching frequency
      4 kHz
      switching frequency
      1...16 kHz adjustable
      4...16 kHz with derating factor
      asynchronous motor control profile
      Voltage/frequency ratio (2 or 5 points)
      ENA (Energy adaptation) system for unbalanced loads
      Sensorless flux vector control (SFVC) (voltage or current vector)
      Flux vector control (FVC) with sensor (current vector)
      type of polarization
      No impedance Modbus
      Complementary
      product destination
      Synchronous motors
      Asynchronous motors
      supply voltage limits
      170...264 V
      supply frequency
      50...60 Hz (- 5...5 %)
      network frequency
      47.5...63 Hz
      speed range
      1...100 asynchronous motor in open-loop mode, without speed feedback
      1...50 synchronous motor in open-loop mode, without speed feedback
      1...1000 asynchronous motor in closed-loop mode with encoder feedback
      speed accuracy
      +/- 0.01 % of nominal speed 0.2 Tn to Tn torque variation in closed-loop mode with encoder feedback
      +/- 10 % of nominal slip 0.2 Tn to Tn torque variation without speed feedback
      torque accuracy
      +/- 15 % in open-loop mode, without speed feedback
      +/- 5 % in closed-loop mode with encoder feedback
      transient overtorque
      220 % of nominal motor torque +/- 10 %for 2 s
      170 % of nominal motor torque +/- 10 %for 60 s every 10 minutes
      braking torque
      <= 150 % with braking or hoist resistor
      30 % without braking resistor
      synchronous motor control profile
      Vector control without speed feedback
      regulation loop
      Adjustable PI regulator
      motor slip compensation
      Adjustable
      Not available in voltage/frequency ratio (2 or 5 points)
      Suppressable
      Automatic whatever the load
      local signalling
      1 LED red presence of drive voltage
      output voltage
      <= power supply voltage
      insulation
      Electrical between power and control
      type of cable
      With a NEMA Type1 kit: 3-strand UL 508 cableat 104 °F (40 °C), copper 75 °C PVC
      With an IP21 or an IP31 kit: 3-strand IEC cableat 104 °F (40 °C), copper 70 °C PVC
      Without mounting kit: 1-strand IEC cableat 113 °F (45 °C), copper 70 °C PVC
      Without mounting kit: 1-strand IEC cableat 113 °F (45 °C), copper 90 °C XLPE/EPR
      electrical connection
      AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR terminal 2.5 mm² / AWG 14
      L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB terminal 4 mm² / AWG 10
      tightening torque
      AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR 5.31 lbf.in (0.6 N.m)
      L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB 12.39 lbf.in (1.4 N.m) / 12.3 lb.in
      supply
      Internal supply for reference potentiometer (1 to 10 kOhm), 10.5 V DC +/- 5 %, <= 10 mAfor overload and short-circuit protection
      Internal supply, 24 V DC, voltage limits 21...27 V, <= 200 mAfor overload and short-circuit protection
      analogue input number
      2
      analogue input type
      AI1-/Al1+ bipolar differential voltage +/- 10 V DC, input voltage 24 V max, resolution 11 bits + sign
      AI2 software-configurable current 0...20 mA, impedance 242 Ohm, resolution 11 bits
      AI2 software-configurable voltage 0...10 V DC, input voltage 24 V max, impedance 30000 Ohm, resolution 11 bits
      sampling duration
      AI1-/Al1+ 2 ms, +/- 0.5 ms analog input(s)
      Al2 2 ms, +/- 0.5 ms analog input(s)
      LI1...LI5 2 ms, +/- 0.5 ms discrete input(s)
      LI6 (if configured as logic input) 2 ms, +/- 0.5 ms discrete input(s)
      response time
      <= 100 ms in STO (Safe Torque Off)
      AO1 2 ms, tolerance +/- 0.5 ms analog output(s)
      R1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms discrete output(s)
      R2A, R2B 7 ms, tolerance +/- 0.5 ms discrete output(s)
      accuracy
      AI1-/Al1+ +/- 0.6 % for a temperature variation 60 °C
      AI2 +/- 0.6 % for a temperature variation 60 °C
      AO1 +/- 1 % for a temperature variation 60 °C
      linearity error
      AI1-/Al1+, AI2 +/- 0.15 % of maximum value
      AO1 +/- 0.2 %
      analogue output number
      1
      analogue output type
      AO1 software-configurable current 0...20 mA, impedance 500 Ohm, resolution 10 bits
      AO1 software-configurable logic output 10 V <= 20 mA
      AO1 software-configurable voltage 0...10 V DC, impedance 470 Ohm, resolution 10 bits
      discrete output number
      2
      discrete output type
      R1A, R1B, R1C configurable relay logic NO/NC, electrical durability 100000 cycles
      R2A, R2B configurable relay logic NO, electrical durability 100000 cycles
      minimum switching current
      Configurable relay logic 3 mAat 24 V DC
      maximum switching current
      R1, R2 on resistive load, 5 Aat 250 V AC, cos phi = 1,
      R1, R2 on resistive load, 5 Aat 30 V DC, cos phi = 1,
      R1, R2 on inductive load, 2 Aat 250 V AC, cos phi = 0.4,
      R1, R2 on inductive load, 2 Aat 30 V DC, cos phi = 0.4,
      discrete input number
      7
      discrete input type
      LI6: switch-configurable 24 V DC with level 1 PLC, impedance: 3500 Ohm
      PWR: safety input 24 V DC, impedance: 1500 Ohm conforming to ISO 13849-1 level d
      LI1...LI5: programmable 24 V DC with level 1 PLC, impedance: 3500 Ohm
      LI6: switch-configurable PTC probe 0...6, impedance: 1500 Ohm
      discrete input logic
      LI1...LI5 positive logic (source), < 5 V (state 0), > 11 V (state 0)
      LI1...LI5 negative logic (sink), > 16 V (state 0), < 10 V (state 0)
      LI6 (if configured as logic input) positive logic (source), < 5 V (state 0), > 11 V (state 0)
      LI6 (if configured as logic input) negative logic (sink), > 16 V (state 0), < 10 V (state 0)
      acceleration and deceleration ramps
      Linear adjustable separately from 0.01 to 9000 s
      Automatic adaptation of ramp if braking capacity exceeded, by using resistor
      S, U or customized
      braking to standstill
      By DC injection
      protection type
      Drive against exceeding limit speed
      Drive against input phase loss
      Drive break on the control circuit
      Drive input phase breaks
      Drive line supply overvoltage
      Drive line supply undervoltage
      Drive overcurrent between output phases and earth
      Drive overheating protection
      Drive overvoltages on the DC bus
      Drive short-circuit between motor phases
      Drive thermal protection
      Motor motor phase break
      Motor power removal
      Motor thermal protection
      insulation resistance
      > 1 mOhm at 500 V DC for 1 minute to earth
      frequency resolution
      Analog input 0.024/50 Hz
      Display unit 0.1 Hz
      communication port protocol
      CANopen
      Modbus
      connector type
      1 RJ45 Modbus on front face
      1 RJ45 Modbus on terminal
      Male SUB-D 9 on RJ45 CANopen
      physical interface
      2-wire RS 485 Modbus
      transmission frame
      RTU Modbus
      transmission rate
      20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen
      4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal
      9600 bps, 19200 bps Modbus on front face
      data format
      8 bits, 1 stop, even parity Modbus on front face
      8 bits, odd even or no configurable parity Modbus on terminal
      number of addresses
      1...247 Modbus
      1...127 CANopen
      method of access
      Slave CANopen
      marking
      CE
      operating position
      Vertical +/- 10 degree
      height
      9.06 in (230 mm)
      depth
      6.89 in (175 mm)
      width
      5.12 in (130 mm)
      product weight
      6.61 lb(US) (3 kg)
      option card
      CC-Link communication card
      Controller inside programmable card
      DeviceNet communication card
      Ethernet/IP communication card
      Fipio communication card
      I/O extension card
      Interbus-S communication card
      Interface card for encoder
      Modbus Plus communication card
      Modbus TCP communication card
      Modbus/Uni-Telway communication card
      Overhead crane card
      Profibus DP communication card
      Profibus DP V1 communication card
      Environment
      noise level
      43 dB conforming to 86/188/EEC
      dielectric strength
      2830 V DC between earth and power terminals
      4230 V DC between control and power terminals
      electromagnetic compatibility
      Conducted radio-frequency immunity test conforming to IEC 61000-4-6 level 3
      Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 level 4
      Electrostatic discharge immunity test conforming to IEC 61000-4-2 level 3
      Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 level 3
      Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
      1.2/50 µs - 8/20 µs surge immunity test conforming to IEC 61000-4-5 level 3
      standards
      EN/IEC 61800-5-1
      IEC 60721-3-3 class 3S2
      UL Type 1
      EN 61800-3 environments 1 category C2
      EN 61800-3 environments 2 category C2
      EN 55011 class A group 1
      EN/IEC 61800-3
      IEC 60721-3-3 class 3C1
      product certifications
      GOST
      CSA
      NOM 117
      C-Tick
      UL
      pollution degree
      2 conforming to EN/IEC 61800-5-1
      IP degree of protection
      IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529
      IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1
      IP21 conforming to EN/IEC 60529
      IP21 conforming to EN/IEC 61800-5-1
      IP41 on upper part conforming to EN/IEC 60529
      IP41 on upper part conforming to EN/IEC 61800-5-1
      IP54 on lower part conforming to EN/IEC 60529
      IP54 on lower part conforming to EN/IEC 61800-5-1
      vibration resistance
      1.5 mm peak to peak (f = 3...13 Hz) conforming to EN/IEC 60068-2-6
      1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6
      shock resistance
      15 gn 11 ms conforming to EN/IEC 60068-2-27
      relative humidity
      5...95 % without condensation conforming to IEC 60068-2-3
      5...95 % without dripping water conforming to IEC 60068-2-3
      ambient air temperature for operation
      14...122 °F (-10...50 °C) without derating
      ambient air temperature for storage
      -13...158 °F (-25...70 °C)
      operating altitude
      <= 3280.84 ft (1000 m) without derating
      3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m
      Ordering and shipping details
      Category
      22130 - ATV71 - 1/2 THRU 5HP DRIVES
      Discount Schedule
      CP4C
      GTIN
      00785901979548
      Nbr. of units in pkg.
      1
      Package weight(Lbs)
      9.6899999999999995
      Returnability
      N
      Country of origin
      ID
      Contractual warranty
      Warranty period
      18 months
    • Documents and Downloads

      Language
      • English
      • Spanish
      • French
      Catalog
      Date
      Size
      Add to My Documents
      Date 6/21/18
      Size 3.6 MB
      User guide
      Date
      Size
      Add to My Documents
      Date 5/12/17
      Size 2.8 MB
      Date 2/14/18
      Size 4.9 MB
      Date 12/14/17
      Size 180.6 KB
      Date 5/19/17
      Size 4 MB
      Certificate
      Date
      Size
      Add to My Documents
      Date 5/31/18
      Size 45.6 KB
      Date 4/27/18
      Size 2.3 MB
      Date 6/19/18
      Size 106.1 KB
      Software - Released
      Date
      Size
      Add to My Documents
      SoMove V2.6.5 (FDT Standalone)
      Date 6/19/18
      Size 234.4 MB
      Date 6/19/18
      Size 107.1 KB
      DTM files
      Date
      Size
      Add to My Documents
      Altivar DTM Library V12.8: ATV12, ATV31/312, ATV32, ATV61, ATV71, ATV LIFT, ATV212
      Handout
      Date
      Size
      Add to My Documents
      Date 9/24/17
      Size 351.6 KB
      Product Environmental Profile
      Date
      Size
      Add to My Documents
      Date 3/1/18
      Size 687.9 KB
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.