Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

    variable speed drive ATV630 - 3kW - 200...240V - IP21/UL type 1

    Show more characteristics >
    • Product availability
      Stock - Normally stocked in distribution facility
    • Price
      1374.00 USD
    Add to My Favorites Remove from My Favorites

    • Main
      range of product
      Altivar Process ATV600
      product or component type
      Variable speed drive
      product specific application
      Process and utilities
      device short name
      ATV630
      variant
      Standard version
      product destination
      Asynchronous motors
      Synchronous motors
      mounting mode
      Wall mount
      EMC filter
      Without EMC filter
      IP degree of protection
      IP21 conforming to IEC 61800-5-1
      IP21 conforming to IEC 60529
      degree of protection
      UL type 1 UL 508C
      type of cooling
      Forced convection
      supply frequency
      50...60 Hz - 5...5 %
      network number of phases
      3 phases
      [Us] rated supply voltage
      200...240 V - 15...10 %
      motor power kW
      3 kW normal duty
      2.2 kW heavy duty
      motor power hp
      3 hp heavy duty
      4 hp normal duty
      line current
      11.5 A 200 V normal duty
      9.9 A 240 V normal duty
      8.7 A 200 V heavy duty
      7.6 A 240 V heavy duty
      prospective line Isc
      50 kA
      apparent power
      4.1 kVA 240 V normal duty
      3.2 kVA 240 V heavy duty
      continuous output current
      13.7 A 4 kHz normal duty
      11.2 A 4 kHz heavy duty
      maximum transient current
      16.8 A 60 s heavy duty
      15.1 A 60 s normal duty
      asynchronous motor control profile
      Constant torque standard
      Variable torque standard
      Optimized torque mode
      synchronous motor control profile
      Permanent magnet motor
      speed drive output frequency
      0.1...599 Hz
      output frequency
      0.0001...0.5 kHz
      nominal switching frequency
      4 kHz
      switching frequency
      2...12 kHz adjustable
      4...12 kHz with derating factor
      safety function
      STO (safe torque off) SIL 3
      discrete input logic
      16 preset speeds
      communication port protocol
      Ethernet
      Modbus serial
      Modbus TCP
      option card
      Communication module Profibus DP V1 slot A
      Communication module Profinet slot A
      Communication module DeviceNet slot A
      Communication module Modbus TCP/EtherNet/IP slot A
      Communication module CANopen daisy chain RJ45 slot A
      Communication module CANopen SUB-D 9 slot A
      Communication module CANopen screw terminals slot A
      Digital and analog I/O extension module slot A/slot B
      Output relay extension module slot A/slot B
      Communication module Ethernet IP/Modbus TCP/MD-Link slot A
      Complementary
      output voltage
      <= power supply voltage
      permissible temporary current boost
      1.1 x In 60 s normal duty
      1.5 x In 60 s heavy duty
      motor slip compensation
      Adjustable
      Automatic whatever the load
      Can be suppressed
      Not available in permanent magnet motor law
      acceleration and deceleration ramps
      Linear adjustable separately from 0.01...9999 s
      braking to standstill
      By DC injection
      protection type
      Safe torque off motor
      Motor phase break motor
      Safe torque off drive
      Overheating drive
      Short-circuit protection drive
      Motor phase break drive
      Overspeed drive
      Break on the control circuit drive
      Overvoltages on the DC bus drive
      Overload of output voltage drive
      Line supply overvoltage drive
      Line supply phase loss drive
      Line supply undervoltage drive
      Overcurrent between output phases and earth drive
      Thermal protection motor
      Thermal protection drive
      frequency resolution
      Display unit
      Analog input
      electrical connection
      Removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 control
      Screw terminal 4...6 mm² AWG 12...AWG 10 motor
      Screw terminal 2.5...6 mm² AWG 14...AWG 10 line side
      connector type
      RJ45 Ethernet/Modbus TCP on the remote graphic terminal
      RJ45 Modbus serial on the remote graphic terminal
      physical interface
      2-wire RS 485 Modbus serial
      transmission frame
      RTU Modbus serial
      transmission rate
      10/100 Mbit/s Ethernet IP/Modbus TCP
      4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
      exchange mode
      Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
      data format
      8 bits, configurable odd, even or no parity Modbus serial
      type of polarization
      No impedance Modbus serial
      number of addresses
      1...247 Modbus serial
      method of access
      Slave Modbus TCP
      supply
      Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 % <= 10 mA overload and short-circuit protection
      External supply for digital inputs 24 V DC 19...30 V <= 1.25 mA overload and short-circuit protection
      Internal supply for digital inputs and STO 24 V DC 21...27 V <= 200 mA overload and short-circuit protection
      local signalling
      3 LEDs local diagnostic
      3 LEDs dual colour embedded communication status
      4 LEDs dual colour communication module status
      1 LED red presence of voltage
      width
      5.67 in (144 mm)
      height
      12.6 in (320 mm)
      depth
      7.99 in (203 mm)
      product weight
      9.92 lb(US) (4.5 kg)
      analogue input number
      3
      analogue input type
      Software-configurable voltage AI1, AI2, AI3 0...10 V DC 30 kOhm 12 bits
      Software-configurable current AI1, AI2, AI3 0...20 mA/4...20 mA 250 Ohm 12 bits
      discrete input number
      8
      discrete input type
      Programmable DI1...DI6 24 V DC 3.5 kOhm
      Programmable as pulse input DI5, DI6 0...30 kHz 24 V DC
      Safe torque off STOA, STOB 24 V DC > 2.2 kOhm
      input compatibility
      Level 1 PLC EN/IEC 61131-2 DI1...DI6 discrete input
      Level 1 PLC IEC 65A-68 DI5, DI6 discrete input
      Level 1 PLC EN/IEC 61131-2 STOA, STOB discrete input
      discrete input logic
      Positive logic (source) DI1...DI6 < 5 V > 11 V
      Negative logic (sink) DI1...DI6 > 16 V < 10 V
      Positive logic (source) DI5, DI6 < 0.6 V > 2.5 V
      Positive logic (source) STOA, STOB < 5 V > 11 V
      analogue output number
      2
      analogue output type
      Software-configurable voltage AO1, AO2 0...10 V DC 470 Ohm 10 bits
      Software-configurable current AO1, AO2 0...20 mA 10 bits
      sampling duration
      2 ms +/- 0.5 ms DI1...DI4 discrete input
      5 ms +/- 1 ms DI5, DI6 discrete input
      5 ms +/- 0.1 ms AI1, AI2, AI3 analog input
      10 ms +/- 1 ms AO1 analog output
      accuracy
      +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
      +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
      linearity error
      +/- 0.15 % of maximum value analog input AI1, AI2, AI3
      +/- 0.2 % analog output AO1, AO2
      relay output number
      3
      relay output type
      Configurable relay logic R1 fault relay NO/NC 100000 cycles
      Configurable relay logic R2 sequence relay NO 100000 cycles
      Configurable relay logic R3 sequence relay NO 100000 cycles
      refresh time
      5 ms +/- 0.5 ms R1, R2, R3 relay output
      minimum switching current
      5 mA 24 V DC R1, R2, R3 relay output
      maximum switching current
      3 A 250 V AC resistive 1 R1, R2, R3 relay output
      3 A 30 V DC resistive 1 R1, R2, R3 relay output
      2 A 250 V AC inductive 0.4 7 ms R1, R2, R3 relay output
      2 A 30 V DC inductive 0.4 7 ms R1, R2, R3 relay output
      isolation
      Between power and control terminals
      specific application
      Utility
      IP degree of protection
      IP21
      discrete and process manufacturing
      Building - HVAC compressor centrifugal
      Food and beverage processing other application
      Mining mineral and metal fan
      Mining mineral and metal pump
      Oil and gas fan
      Water and waste water other application
      Building - HVAC screw compressor
      Food and beverage processing pump
      Food and beverage processing fan
      Food and beverage processing atomization
      Oil and gas electro submersible pump (ESP)
      Oil and gas water injection pump
      Oil and gas jet fuel pump
      Oil and gas compressor for refinery
      Water and waste water centrifuge pump
      Water and waste water positive displacement pump
      Water and waste water electro submersible pump (ESP)
      Water and waste water screw pump
      Water and waste water lobe compressor
      Water and waste water screw compressor
      Water and waste water compressor centrifugal
      Water and waste water fan
      Water and waste water conveyor
      Water and waste water mixer
      power range
      2.2...3 kW 200...240 V 3 phases
      motor starter type
      Variable speed drive
      Environment
      insulation resistance
      > 1 MOhm 500 V DC for 1 minute to earth
      noise level
      54.5 dB 86/188/EEC
      power dissipation in W
      34 W natural convection 200 V 4 kHz
      104 W forced convection 200 V 4 kHz
      volume of cooling air
      10038.72 Gal/hr(US) (38 m3/h)
      operating position
      Vertical +/- 10 degree
      THDI
      <= 48 % full load IEC 61000-3-12
      electromagnetic compatibility
      Conducted radio-frequency immunity test level 3 IEC 61000-4-6
      1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5
      Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
      Electrostatic discharge immunity test level 3 IEC 61000-4-2
      Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
      pollution degree
      2 EN/IEC 61800-5-1
      vibration resistance
      1.5 mm peak to peak 2...13 Hz IEC 60068-2-6
      1 gn 13...200 Hz IEC 60068-2-6
      shock resistance
      15 gn 11 ms IEC 60068-2-27
      relative humidity
      5...95 % without condensation IEC 60068-2-3
      ambient air temperature for operation
      5...122 °F (-15...50 °C) without derating
      122...140 °F (50...60 °C) with derating factor
      ambient air temperature for storage
      -40...158 °F (-40...70 °C)
      operating altitude
      1000...4800 m with current derating 1 % per 100 m
      <= 3280.84 ft (1000 m) without derating
      environmental characteristic
      Chemical pollution resistance class 3C3 EN/IEC 60721-3-3
      Dust pollution resistance class 3S3 EN/IEC 60721-3-3
      standards
      EN/IEC 61800-3
      EN/IEC 61800-3 environment 1 category C2
      EN/IEC 61800-3 environment 2 category C3
      UL 508C
      EN/IEC 61800-5-1
      IEC 61000-3-12
      IEC 60721-3
      IEC 61508
      IEC 13849-1
      product certifications
      ATEX INERIS
      ATEX zone 2/22
      CSA
      TÜV
      UL
      REACH
      DNV-GL
      marking
      CE
      Ordering and shipping details
      Category
      22205 - ATV630 FRAMES 1 & 2
      Discount Schedule
      CP4E
      GTIN
      00785901966968
      Nbr. of units in pkg.
      1
      Package weight(Lbs)
      13.280000000000001
      Returnability
      Y
      Country of origin
      ID
      Offer Sustainability
      Sustainable offer status
      Green Premium product
      RoHS (date code: YYWW)
      Compliant  - since  1444  -  Schneider Electric declaration of conformity Schneider Electric declaration of conformity
      REACh
      Product environmental profile
      Product end of life instructions
      Available End of life manual
      California proposition 65
      WARNING: This product can expose you to chemicals including:
      - - - - - - - Substance 1
      Lead and lead compounds which is known to the State of California to cause cancer and birth defects or other reproductive harm.
      - - - - - - - More information
      For more information go to www.p65warnings.ca.gov
    • Documents and Downloads

      Language
      • English
      • Spanish
      • French
      Software - Released
      Date
      Size
      Add to My Documents
      SoMove V2.6.5 (FDT Standalone)
      Date 6/19/18
      Size 234.4 MB
      Date 6/19/18
      Size 107.1 KB
      Languages for VW3A1111 Advanced graphic display terminal (U0.079)
      DTM files
      Date
      Size
      Add to My Documents
      Date 5/28/18
      Size 16.2 MB
      Altivar Process ATV6xx DTM Library V2.2.1
      Catalog
      Date
      Size
      Add to My Documents
      User guide
      Date
      Size
      Add to My Documents
      Date 6/12/18
      Size 291.2 KB
      Date 3/30/18
      Size 5 MB
      Date 3/1/18
      Size 1.3 MB
      Date 6/26/18
      Size 1.9 MB
      Date 10/19/15
      Size 1.8 MB
      Date 6/26/18
      Size 1.5 MB
      Date 8/6/18
      Size 123.7 KB
      Date 6/8/15
      Size 2.3 MB
      Date 10/21/16
      Size 3.5 MB
      Date 8/6/18
      Size 1.8 MB
      Date 5/23/18
      Size 5.3 MB
      Date 5/23/18
      Size 4.7 MB
      Certificate
      Date
      Size
      Add to My Documents
      Date 6/22/18
      Size 3.6 MB
      Date 6/19/18
      Size 974.1 KB
      Date 5/31/18
      Size 382 KB
      Date 4/27/18
      Size 1.3 MB
      Date 4/6/18
      Size 87.8 KB
      Instruction Sheet
      Date
      Size
      Add to My Documents
      GDS files
      Date
      Size
      Add to My Documents
      Date 5/18/18
      Size 79 KB
      Date 5/24/18
      Size 76.1 KB
      Application solutions
      Date
      Size
      Add to My Documents
      EDS Files
      Date
      Size
      Add to My Documents
      Date 12/8/16
      Size 53.7 KB
      Product Environmental Profile
      Date
      Size
      Add to My Documents
      Date 3/27/18
      Size 1.1 MB
    • Technical FAQs

      No results found.
      Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
    • Dimensions Drawings

      Dimensions
      Drives with IP21 Top Cover

      Right and Front View

      Drives Without IP21 Top Cover

      Left and Rear View


    • Mounting and Clearance

      Clearances


      X1

      X2

      X3

      ≥ 100 mm (3.94 in.)

      ≥ 100 mm (3.94 in.)

      ≥ 10 mm (0.39 in.)


      Mounting Types
      Mounting Type A: Individual IP21


      a ≥
      100 mm (3.94 in.)

      Mounting Type B: Side by Side IP20


      Mounting Type C: Individual IP20


      a ≥
      0


    • Connections and Schema

      Three-Phase Power Supply with Upstream Breaking via Line Contactor

      Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1


      (1)
      Line choke if used
      (2)
      Use relay output R1 set to operating state Fault to switch Off the product once an error is detected.
      A1 :
      Drive
      KM1 :
      Line Contactor
      Q2, Q3 :
      Circuit breakers
      S1, S2 :
      Pushbuttons
      T1 :
      Transformer for control part


      Three-Phase Power Supply with Downstream Breaking Contactor

      Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance with standard IEC/EN 60204-1


      (1)
      Line choke if used
      (2)
      Use relay output R1 set to operating state Fault to switch Off the product once an error is detected.
      A1 :
      Drive
      KM1 :
      Contactor


      Control Block Wiring Diagram


      (1)
      Safe Torque Off
      (2)
      Analog Output
      (3)
      Digital Input
      (4)
      Reference potentiometer
      (5)
      Analog Input
      R1A, R1B, R1C :
      Fault relay
      R2A, R2C :
      Sequence relay
      R3A, R3C :
      Sequence relay

      Sensor Connection

      It is possible to connect either 1 or 3 sensors on terminals AI2 or AI3.



      Sink / Source Switch Configuration

      The switch is used to adapt the operation of the logic inputs to the technology of the programmable controller outputs.

      • Set the switch to Source (factory setting) if using PLC outputs with PNP transistors.

      • Set the switch to Ext if using PLC outputs with NPN transistors.

      Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs


      Switch Set to SRC (Source) Position and Use of an External Power Supply for the DIs


      Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs


      Switch Set to EXT Position Using an External Power Supply for the DIs



    • Performance Curves

      Derating Curves


      40 °C (104 °F) - Mounting type A, B and C
      50 °C (122 °F) - Mounting type A, B and C
      60 °C (140 °F) - Mounting type B and C
      In :
      Nominal Drive Current
      SF :
      Switching Frequency


    • Motor Starter BOM

      Our Proposal: Circuit Breaker + Contactor + Drive for Motor Power 3 kW and 200 VAC

      Motor power

      (kW)

      ICU

      (kA)

      Breaker

      Contactor (*)

      Motor Starter

      3

      130


      GV2L16


      LC1D18P7


      ATV630U30M3

      Non contractual pictures.

      (*) You can select the contactor proposed or variants. Please consider examples hereafter or follow the link to the complete offer.

      Motor power

      kW

      Coil voltage

      VAC - 50/60 Hz

      24

      48

      110

      115

      220

      230

      400

      Other

      3

      LC1D18 ..

      B7

      E7

      F7

      FE7

      M7

      P7

      V7

      Complete Offer

      Motor power

      kW

      Coil voltage

      VDC

      24

      48

      110

      125

      220

      230

      Other

      3

      LC1D18 ..

      BD

      ED

      -

      -

      -

      -

      Complete Offer

      Motor power

      kW

      Coil voltage

      Low Consumption

      VDC - U 0.8…1.25 Uc

      24

      110

      Other

      3

      LC1D18 ..

      BL

      FL

      Complete Offer