Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

Schneider Eletric ABL8RPS24050 Picture

Range: Phaseo ABL7, ABL8

Power supplies

ABL8RPS24050

Schneider Eletric ABL8RPS24050 Picture
Range: Phaseo ABL7, ABL8

Power supplies

ABL8RPS24050

regulated SMPS - 1 or 2-phase - 100..500 V - 24 V - 5 A

Show more characteristics >
  • Product availability
    Stock - Normally stocked in distribution facility
  • Price
    360.00 USD
Add to My Products Remove from My Products

  • Main
    range of product
    Phaseo
    product or component type
    Power supply
    power supply type
    Regulated switch mode
    input voltage
    100...120 V AC single phase, terminal(s): N-L1
    200...500 V AC phase to phase, terminal(s): L1-L2
    output voltage
    24 V DC
    rated power in W
    120 W
    provided equipment
    Power factor correction filter conforming to IEC 61000-3-2
    power supply output current
    5 A
    output protection type
    Against overload, protection technology: manual or automatic reset
    Against overvoltage, protection technology: 30...32 V, manual reset
    Against short-circuits, protection technology: manual or automatic reset
    Against undervoltage, protection technology: tripping if U < 21.6 V
    Thermal, protection technology: automatic reset
    ambient air temperature for operation
    122...140 °F (50...60 °C) with
    -13...122 °F (-25...50 °C) without
    Complementary
    input voltage limits
    170...550 V
    85...132 V
    network frequency
    47...63 Hz
    inrush current
    30 A for 2 ms
    cos phi
    0.51 at 240 V
    0.59 at 120 V
    efficiency
    87 %
    output voltage limits
    24...28.8 V adjustable
    power dissipation in W
    15.5 W
    line and load regulation
    1...3 %
    holding time
    >= 120 ms at 400 V
    >= 20 ms at 100 V
    >= 40 ms at 240 V
    permissible temporary current boost
    1.5 x In for 4 s
    connections - terminals
    Screw type terminals input connection, connection capacity: 3 x 0.5...3 x 4 mm² AWG 22...AWG 12
    Screw type terminals input ground connection, connection capacity: 1 x 0.5...1 x 4 mm² AWG 22...AWG 12
    Screw type terminals output connection, connection capacity: 4 x 0.5...4 x 4 mm² AWG 22...AWG 12
    Screw type terminals output ground connection, connection capacity: 1 x 0.5...1 x 4 mm² AWG 22...AWG 12
    Removable screw terminal block diagnostic relay, connection capacity: 2 x 2.5 mm²
    marking
    CE
    mounting support
    35 x 15 mm symmetrical DIN rail
    35 x 7.5 mm symmetrical DIN rail
    operating position
    Vertical
    operating altitude
    6561.68 ft (2000 m)
    output coupling
    Parallel
    Series
    name of test
    Harmonic current emission conforming to EN/IEC 61000-3-2
    Conducted emissions on the power line conforming to EN 55022 Class B
    Electrostatic discharges conforming to EN/IEC 61000-4-2
    Induced electromagnetic field conforming to EN/IEC 61000-4-6
    Magnetic field conforming to EN 61000-4-8
    Primary outage conforming to IEC 61000-4-11
    Radiated electromagnetic field conforming to EN/IEC 61000-4-3
    Radiated emissions conforming to EN 55022 Class B
    Rapid transient conforming to IEC 61000-4-4
    Surge conforming to EN/IEC 61000-4-5
    status LED
    1 LED green and red output voltage
    1 LED green, red and orange output current
    depth
    4.92 in (125 mm)
    height
    5.63 in (143 mm)
    width
    2.2 in (56 mm)
    product weight
    1.54 lb(US) (0.7 kg)
    Environment
    product certifications
    CCSAus
    UL
    KC
    standards
    UL 508
    CSA C22.2 No 60950-1
    environmental characteristic
    EMC conforming to EN 61000-6-1
    EMC conforming to EN 61000-6-3
    EMC conforming to EN/IEC 61000-6-2
    EMC conforming to EN/IEC 61000-6-4
    EMC conforming to EN/IEC 61204-3
    Safety conforming to EN/IEC 60950-1
    Safety conforming to EN/IEC 61204-3
    Safety conforming to SELV
    IP degree of protection
    IP20 conforming to EN/IEC 60529
    ambient air temperature for storage
    -40...158 °F (-40...70 °C)
    relative humidity
    0...90 % during operation
    0...95 % in storage
    overvoltage category
    Class I conforming to VDE 0106-1
    dielectric strength
    Between input and ground
    Between output and ground
    Between input and output
    MTBF reliability
    915000 H at 100 V AC with UTE C80-810 calculation method
    950000 H at 200...500 V AC with UTE C80-810 calculation method
    Ordering and shipping details
    Category
    22525 - ABL8 AND ABL7 POWER SUPPLIE
    Discount Schedule
    CP12
    GTIN
    00785901593683
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    1.97
    Returnability
    Y
    Country of origin
    PH
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    RoHS (date code: YYWW)
    REACh
    Product environmental profile
    Available
    Product end of life instructions
    Available
    California proposition 65
    WARNING: This product can expose you to chemicals including:
    - - - - - - - Substance 1
    Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm.
    - - - - - - - More information
    For more information go to www.p65warnings.ca.gov
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • Spanish
    Catalog
    Date
    Size
    Add to My Documents
    Date 12/13/17
    Size 1.2 MB
    Digest 177 Sec. 23: Relays and Timers
    Date 3/23/18
    Size 6.5 MB
    User guide
    Date
    Size
    Add to My Documents
    Date 12/14/17
    Size 3 MB
    Date 1/22/16
    Size 11 MB
    CAD
    Date
    Size
    Add to My Documents
    Universal Power Supply 5A
    Date 9/29/11
    Size 4.4 KB
    Date 9/29/11
    Size 372.2 KB
    Date 9/29/11
    Size 3.2 MB
    Date 9/29/11
    Size 6.7 KB
    Universal Power Supply 5A
    Date 9/29/11
    Size 5.2 KB
    Date 9/29/11
    Size 385.5 KB
    Date 9/29/11
    Size 3.3 MB
    Date 9/29/11
    Size 8.3 KB
    Instruction Sheet
    Date
    Size
    Add to My Documents
    Date 7/18/18
    Size 409.3 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Regulated Switch Mode Power Supplies
    Dimensions


    ABL 8

    a in mm

    a in in.

    b in mm

    b in in.

    RPS24030

    120

    4.72

    44

    1.73

    RPS24050

    120

    4.72

    56

    2.20

    RPS24100

    140

    5.51

    85

    3.34

    RPM24200

    140

    5.51

    145

    5.70

    WPS24200

    155

    6.10

    95

    3.74

    WPS24400

    155

    6.10

    165

    6.49


  • Connections and Schema

    Regulated Switch Mode Power Supply
    Internal Wiring Diagram



    Regulated Switch Mode Power Supply
    Line Supply Wiring Diagram

    Single-phase (L-N) 100 to 120 V


    Phase-to-phase (L1-L2) 200 to 500 V


    Single-phase (L-N) 200 to 500 V



    Regulated Switch Mode Power Supplies
    Series or Parallel Connection

    Series Connection


    (1)
    Two Shottky diodes Imin = power supply In and Vmin = 50 V

    Parallel Connection


    Family

    Series

    Parallel

    ABL 8RPS/8RPM/8WPS

    2 products max. (1)

    2 products max.

    Series or parallel connection is only recommended for products with identical references.

    For better availability, the power supplies can also be connected in parallel using the ABL8RED24400 Redundancy module.


  • Performance Curves

    Regulated Switch Mode Power Supplies
    Derating

    The ambient temperature is a determining factor that limits the power an electronic power supply can deliver continuously. If the temperature around the electronic components is too high, their life will be significantly reduced.

    The nominal ambient temperature for the Universal range of Phaseo power supplies is 50°C. Above this temperature, derating is necessary up to a maximum temperature of 60°C.

    The graph below shows the power (in relation to the nominal power) that the power supply can deliver continuously, depending on the ambient temperature.


    X
    Maximum operating temperature (°C)

    ABL 8RPM, ABL 8RPS, ABL 8WPS mounted vertically

    Derating should be considered in extreme operating conditions:

    • Intensive operation (output current permanently close to the nominal current, combined with a high ambient temperature)

    • Output voltage set above 24 Vdc (to compensate for line voltage drops, for example)

    • Parallel connection to increase the total power


    Regulated Switch Mode Power Supply
    Load Limit

    Manual Reset Protection Mode


    (1)
    Boost 4s

    Automatic Reset Protection Mode


    (1)
    Boost 4s

    “Boost” Repeat Accuracy


    This type of operation is described in detail in the user manual, which can be downloaded from the website.