Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

Schneider Eletric 56230 Picture

Range: Vigirex Ground-fault Relay System

Residual-current protection relays

56230

Schneider Eletric 56230 Picture
Range: Vigirex Ground-fault Relay System

Residual-current protection relays

56230

Earth-leakage relay RH10P - 30 mA - 240 V

Show more characteristics >
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
Add to My Products Remove from My Products

  • Main
    range
    Vigirex
    range of product
    Vigirex
    device short name
    RH10P
    product or component type
    Residual current protection relay
    range compatibility
    Vigirex RH TOA earth leakage current sensor
    Vigirex RH A earth leakage current sensor
    relay application
    Residual current protection relay
    Complementary
    earthing system
    IT
    TN-S
    TT
    [Us] rated supply voltage
    220...240 V AC at 50/60 Hz
    220...240 V AC at 400 Hz
    power consumption in VA
    4 VA
    type of measurement
    Earth fault current internal measurement 80...100 %
    residual earth-leakage time delay adjustment type
    Instantaneous 0.03 A
    test function
    Local
    Remote test
    monitoring
    Electronics (continuous)
    Power supply (continuous)
    Relay/sensor link (continuous)
    [Ithe] conventional enclosed thermal current
    8 A
    minimum load
    10 mA at 12 V
    product weight
    0.66 lb(US) (0.3 kg)
    mechanical robustness
    IK protection 2 joules IK07 conforming to EN 50102
    IP protection IP20 conforming to IEC 60529
    IP protection IP30 conforming to IEC 60529
    IP protection IP40 conforming to IEC 60529
    Vibrations 13.2...100 Hz 0.7 g
    Vibrations 2...13.2 Hz +/- 1 mm
    Fire resistance conforming to IEC 60695-2-1
    earth-leakage protection class
    Class A si
    Class AC
    overvoltage category
    IV
    tamperproof of settings
    Protected by sealable cover
    mounting support
    Panel
    height
    2.83 in (72 mm)
    width
    2.83 in (72 mm)
    depth
    3.07 in (78 mm)
    connections - terminals
    Terminal block auxiliary power supply 0...0 in² (0.2...2.5 mm²) flexible AWG 24...AWG 12
    Terminal block auxiliary power supply 0...0 in² (0.2...2.5 mm²) rigid AWG 24...AWG 12
    Terminal block fault 0.2...2.5 mm² flexible AWG 24...AWG 12
    Terminal block fault 0.2...2.5 mm² rigid AWG 24...AWG 12
    Terminal block relay test and fault reset 0.2...2.5 mm² flexible AWG 24...AWG 12
    Terminal block relay test and fault reset 0.2...2.5 mm² rigid AWG 24...AWG 12
    Terminal block sensor 0.2...2.5 mm² flexible AWG 24...AWG 12
    Terminal block sensor 0.2...2.5 mm² rigid AWG 24...AWG 12
    Terminal block voltage presence 0.2...2.5 mm² flexible AWG 24...AWG 12
    Terminal block voltage presence 0.2...2.5 mm² rigid AWG 24...AWG 12
    Terminal block auxiliary power supply 0...0 in² (0.25...2.5 mm²) flexible AWG 24...AWG 12
    Terminal block fault 0.25...2.5 mm² flexible AWG 24...AWG 12
    Terminal block relay test and fault reset 0.25...2.5 mm² flexible AWG 24...AWG 12
    Terminal block sensor 0.25...2.5 mm² flexible AWG 24...AWG 12
    Terminal block voltage presence 0.25...2.5 mm² flexible AWG 24...AWG 12
    wire stripping length
    Fault : 7 mm
    Sensor : 7 mm
    Voltage presence : 7 mm
    Auxiliary power supply : 7 mm
    Relay test and fault reset : 7 mm
    tightening torque
    Auxiliary power supply : 0.6 N.m
    Fault : 0.6 N.m
    Relay test and fault reset : 0.6 N.m
    Sensor : 0.6 N.m
    Voltage presence : 0.6 N.m
    Environment
    ambient air temperature for operation
    -31...158 °F (-35...70 °C)
    ambient air temperature for storage
    -67...185 °F (-55...85 °C)
    electromagnetic compatibility
    Conducted and radiated emissions: B conforming to CISPR 11
    Conducted radio-frequency immunity test: 3 conforming to IEC 61000-4-6
    Electrostatic discharge immunity test: 4 conforming to IEC 61000-4-2
    High-energy conducted susceptibility: 4 conforming to IEC 61000-4-5
    Low-energy conducted susceptibility: 4 conforming to IEC 61000-4-4
    Radiated susceptibility: 3 conforming to IEC 61000-4-3
    electrical shock protection class
    Class II
    Ordering and shipping details
    Category
    01101 - NF..E COMPACT NS IEC CIRCUIT BREAKERS, SWITCHES & MCP'S
    Discount Schedule
    DE2
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    1.5
    Returnability
    N
    Country of origin
    FR
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    Catalog
    Date
    Size
    Add to My Documents
    Date 8/14/18
    Size 19.5 MB
  • Technical FAQs

    No results found.