Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

Schneider Eletric 56170 Picture
Discontinued

Range: Vigirex Ground-fault Relay System

Residual-current protection relays

56170

Schneider Eletric 56170 Picture
Discontinued
Range: Vigirex Ground-fault Relay System

Residual-current protection relays

56170

Earth-leakage relay RH99M with manual reset - 0.03..30 A - 0..4.5 s - 24 V

Show more characteristics >
56170  has not been replaced. Please contact your customer care center for more information.
  • Price
    2970.00 USD
Add to My Products Remove from My Products

  • Main
    range
    Vigirex
    range of product
    Vigirex
    device short name
    RH99M
    product or component type
    Residual current protection relay
    range compatibility
    Vigirex RH TOA earth leakage current sensor
    Vigirex RH A earth leakage current sensor
    relay application
    Residual current protection relay
    Complementary
    earthing system
    IT
    TN-S
    TT
    [Us] rated supply voltage
    12...24 V AC at 50/60 Hz
    12...48 V DC
    power consumption in VA
    4 VA
    type of measurement
    Earth fault current internal measurement 80...100 %
    residual earth-leakage time delay adjustment type
    Instantaneous 0.03 A
    Adjustable 9 settings 0.03...30 A 0...4.5 s
    test function
    Local
    Remote test
    monitoring
    Electronics (continuous)
    Power supply (continuous)
    Relay/sensor link (continuous)
    [Ithe] conventional enclosed thermal current
    8 A
    minimum load
    10 mA at 12 V
    product weight
    0.66 lb(US) (0.3 kg)
    mechanical robustness
    IK protection 2 joules IK07 conforming to EN 50102
    IP protection IP20 conforming to IEC 60529
    IP protection IP30 conforming to IEC 60529
    IP protection IP40 conforming to IEC 60529
    Vibrations 13.2...100 Hz 0.7 g
    Vibrations 2...13.2 Hz +/- 1 mm
    Fire resistance conforming to IEC 60695-2-1
    earth-leakage protection class
    Class A si
    Class AC
    overvoltage category
    IV
    tamperproof of settings
    Protected by sealable cover
    mounting support
    DIN rail
    height
    3.82 in (97 mm)
    width
    2.13 in (54 mm)
    depth
    2.91 in (74 mm)
    9 mm pitches
    6
    connections - terminals
    Terminal block auxiliary power supply 0...0 in² (0.2...2.5 mm²) flexible AWG 24...AWG 12
    Terminal block auxiliary power supply 0...0 in² (0.2...2.5 mm²) rigid AWG 24...AWG 12
    Screw terminal fault 0...0 in² (0.2...2.5 mm²) flexible AWG 24...AWG 12
    Screw terminal fault 0...0.01 in² (0.2...4 mm²) rigid AWG 24...AWG 12
    Screw terminal relay test and fault reset 0...0 in² (0.14...1 mm²) flexible AWG 26...AWG 16
    Screw terminal relay test and fault reset 0...0 in² (0.14...1.5 mm²) rigid AWG 26...AWG 16
    Screw terminal sensor 0...0 in² (0.14...1 mm²) flexible AWG 26...AWG 16
    Screw terminal sensor 0...0 in² (0.14...1.5 mm²) rigid AWG 26...AWG 16
    Screw terminal voltage presence 0...0 in² (0.2...2.5 mm²) flexible AWG 24...AWG 12
    Screw terminal voltage presence 0...0.01 in² (0.2...4 mm²) rigid AWG 24...AWG 12
    Terminal block auxiliary power supply 0...0 in² (0.25...2.5 mm²) flexible AWG 24...AWG 12
    Screw terminal fault 0...0 in² (0.25...2.5 mm²) flexible AWG 24...AWG 12
    Screw terminal relay test and fault reset 0...0 in² (0.25...0.5 mm²) flexible AWG 26...AWG 16
    Screw terminal sensor 0...0 in² (0.25...0.5 mm²) flexible AWG 26...AWG 16
    Screw terminal voltage presence 0...0 in² (0.25...2.5 mm²) flexible AWG 24...AWG 12
    wire stripping length
    Auxiliary power supply: 0.28 in (7 mm) top
    Relay test and fault reset: 0.2 in (5 mm) bottom
    Sensor: 0.2 in (5 mm) top
    Fault: 0.31 in (8 mm) bottom
    Voltage presence: 0.31 in (8 mm) bottom
    tightening torque
    Auxiliary power supply: 5.31 lbf.in (0.6 N.m) top
    Fault: 5.31 lbf.in (0.6 N.m) bottom
    Relay test and fault reset: 2.21 lbf.in (0.25 N.m) bottom
    Sensor: 2.21 lbf.in (0.25 N.m) top
    Voltage presence: 5.31 lbf.in (0.6 N.m) bottom
    Environment
    ambient air temperature for operation
    -31...158 °F (-35...70 °C)
    ambient air temperature for storage
    -67...185 °F (-55...85 °C)
    electromagnetic compatibility
    Conducted and radiated emissions: B conforming to CISPR 11
    Conducted radio-frequency immunity test: 3 conforming to IEC 61000-4-6
    Electrostatic discharge immunity test: 4 conforming to IEC 61000-4-2
    High-energy conducted susceptibility: 4 conforming to IEC 61000-4-5
    Low-energy conducted susceptibility: 4 conforming to IEC 61000-4-4
    Radiated susceptibility: 3 conforming to IEC 61000-4-3
    electrical shock protection class
    Class II
    Ordering and shipping details
    Category
    00992 - UL VIGIREX GROUND FAULT RELAY & SENSOR
    Discount Schedule
    DE2
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    0.53000000000000003
    Returnability
    N
    Country of origin
    FR
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    Catalog
    Date
    Size
    Add to My Documents
    Date 8/14/18
    Size 19.5 MB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.