24122 is replaced by:
Product
Qty
-
Characteristics
Main range Multi 9product name Multi 9 C60product or component type Miniature circuit-breakerdevice short name C60 UL1077device application Distributionpoles description 1Pnumber of protected poles 1[In] rated current 40 A at 77 °F (25 °C)network type DCACtrip unit technology Thermal-magneticcurve code Bbreaking capacity AIR 10 kA at 65 V DC conforming to UL 1077AIR 10 kA at 65 V DC conforming to CSA C22.2 No 235Icu 3 kA at 415 V AC conforming to EN/IEC 60947-2Icu 10 kA at 240 V AC conforming to EN/IEC 60947-2Icu 3 kA at 415 V AC conforming to GB 14048.2Icu 10 kA at 240 V AC conforming to GB 14048.2AIR 5 kA at 277 V AC conforming to UL 1077AIR 10 kA at 240 V AC conforming to UL 1077AIR 5 kA at 277 V AC conforming to CSA C22.2 No 235AIR 10 kA at 240 V AC conforming to CSA C22.2 No 235Icu 10 kA at 60 V DC conforming to EN/IEC 60947-2Icu 10 kA at 60 V DC conforming to GB 14048.2suitability for isolation Yes conforming to EN/IEC 60947-2Complementary network frequency 50/60 HzSystem Voltage 240 V AC60 V DC415 V ACmagnetic tripping limit 4 x In +/- 20% AC5.6 x In +/- 20% DClimitation class 3 conforming to EN/IEC 60947-2[Ui] rated insulation voltage 500 V ACconforming to EN/IEC 60947-2[Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-2contact position indicator Yescontrol type Togglelocal signalling ON/OFF indicationmounting mode Clip-onmounting support DIN rail9 mm pitches 2height 3.19 in (81 mm)width 0.71 in (18 mm)depth 2.87 in (73 mm)product weight 0.24 lb(US) (0.11 kg)colour Greymechanical durability 20000 cycleselectrical durability 10000 cyclesprovision for padlocking Padlockableconnections - terminals Tunnel type terminal, top or bottom rigid wire(s) 0...0.05 in² (2.5...35 mm²) max (AWG 14...AWG 2)wire stripping length 0.55 in (14 mm) top or bottomtightening torque 30.97 lbf.in (3.5 N.m) top or bottomEnvironment standards UL 1077GB 14048.2EN/IEC 60947-2CSA C22.2 No 235product certifications CSACCCIECURIP degree of protection IP40 modular enclosure conforming to IEC 60529IP20 conforming to IEC 60529pollution degree 3 conforming to EN/IEC 60947-2overvoltage category IVtropicalisation 2 conforming to IEC 60068-1relative humidity 95 % 131 °F (55 °C)operating altitude 6561.68 ft (2000 m)ambient air temperature for operation -22...158 °F (-30...70 °C)ambient air temperature for storage -40...176 °F (-40...80 °C)Ordering and shipping details Category 99999 - DEFAULT ADD CATEGORYDiscount Schedule N/ANbr. of units in pkg. 1Package weight(Lbs) 0Returnability NOffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile AvailableProduct end of life instructions Need no specific recycling operationsContractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
EU RoHS DeclarationSizeAdd to My DocumentsREACh DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.