distributed analog/discrete I/O Modicon Momentum
Show more characteristics >-
Product availabilityStock - Normally stocked in distribution facility
-
Characteristics
Main range of product Modicon Momentum automation platformproduct or component type Analogue,discrete I/O basegroup of channels 2 groups of 4 discrete inputs1 group of 6 analog inputs1 group of 4 analog outputs1 group of 8 discrete outputsanalogue input range 0...10 Vanalogue input type Single endedanalogue input resolution 14 bits 0...10 Vdiscrete input voltage 24 V DCanalogue output range 0...10 V 14 bitsdiscrete output voltage 10...30 Voutput short-circuit protection With discrete outputoutput overload protection With discrete outputComplementary discrete input number 8 IEC 1131-2 Type 2[Us] rated supply voltage 24 V 19.2...30 V DCanalogue input voltage <= 15 Vinput voltage limits 3...32 Vdiscrete input logic Positivevoltage state 0 guaranteed <= 5 V discrete inputvoltage state 1 guaranteed >= 11 V discrete inputcurrent state 0 guaranteed <= 2 mA discrete inputcurrent state 1 guaranteed >= 6 mA discrete inputinput overvoltage protection 45 V 10 s discrete inputinput resistance > 1 MOhm analogue input circuitoutput load >= 2 kOhm 0...10 V analogue outputconversion time <= 0.75 ms analogue input circuit1.2 ms analogue outputconversion error 0,002 0...10 V 77 °F (25 °C) analogue input circuit+/- 0.4 % 0...10 V 77 °F (25 °C) analogue outputfail state Hold analogue outputReset to zero analogue outputdiscrete output type Transistordiscrete output logic Positivediscrete output current 2 A per group2 A per module0.25 A per pointleakage current < 0.4 mA DC 30 V discrete outputvoltage drop < 0.4 V 0.25 A at state on discrete outputsurge current 2.5 A 1 ms discrete outputresponse time 1.05 ms from state 1 to state 0 discrete output1.2 ms from state 0 to state 1 discrete input1.2 ms from state 0 to state 1 discrete output1.2 ms from state 1 to state 0 discrete inputisolation voltage 500 V 1 min between analogue I/O and operating voltage500 V 1 min between operating voltage and I/O from groundpower dissipation in W <= 6 Wmarking CElocal signalling 4 LEDs channel statuselectrical connection 2 connectors for removable terminal blockscurrent consumption 400 mA 24 V DCdepth 1.87 in (47.5 mm)height 4.92 in (125 mm)width 5.57 in (141.5 mm)product weight 0.53 lb(US) (0.24 kg)Environment product certifications CSAULprotective treatment TCresistance to electrostatic discharge 4 kV contact IEC 801-28 kV on air IEC 801-2resistance to electromagnetic fields 9.14 V/yd (10 V/m) 80...1000 MHz IEC 801-3ambient air temperature for operation 32...140 °F (0...60 °C)ambient air temperature for storage -40...185 °F (-40...85 °C)relative humidity 95 % without condensationoperating altitude <= 16404.2 ft (5000 m)Ordering and shipping details Category 18206 - MOMENTUM PROCESSORS,I/O BASES,CONN.Discount Schedule PC31GTIN 00785901435150Nbr. of units in pkg. 1Package weight(Lbs) 0.84999999999999998Returnability YCountry of origin IDOffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile AvailableProduct end of life instructions AvailableCalifornia proposition 65 WARNING: This product can expose you to chemicals including:- - - - - - - Substance 1 Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm.- - - - - - - More information For more information go to www.p65warnings.ca.govContractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- French
User guideSizeAdd to My DocumentsModicon Momentum I/O Base, User Guide (Version 20)CertificateSizeAdd to My DocumentsCSA_225844_2591646_MOMENTUM_AUG2017 (Version 1.0)EAC_RUCFRME83B00168_MOMENTUM_DEC2014 (Version 1.0)REACh DeclarationSizeAdd to My DocumentsEU RoHS DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Standard Adapter on a Typical BaseDimensions -
Mounting and Clearance
Mounting on a Wall -
Connections and Schema
External Wiring DiagramsDiscrete I/O DevicesF1, F31 A fuseF22.5 A fuseAnalog I/O DevicesF31 A fuseInternal Pin ConnectionsRows 2 and 3 show the internal connections between terminals on the I/O base. Rows 4 through 6 show the internal connections on the optional busbar.
NOTE: AGND and DGND are separated inside the module. External digital inputs must be returned to the DGND terminal. External analog circuits must be returned to AGND terminals.