Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

Schneider Eletric 140DDM69000C Picture

Range: Modicon Quantum PAC

Harsh environment

140DDM69000C

Schneider Eletric 140DDM69000C Picture
Range: Modicon Quantum PAC

Harsh environment

140DDM69000C

discrete I/O module Modicon Quantum - 4 I - 125 V DC - 4 O

Show more characteristics >
  • Product availability
    Non-Stock - Not normally stocked in distribution facility
  • Price
    2208.00 USD
Add to My Products Remove from My Products

  • Main
    range of product
    Modicon Quantum automation platform
    product or component type
    Mixed discrete I/O module
    discrete I/O number
    8
    Complementary
    discrete input number
    4 1 group of 8
    discrete input logic
    Sink
    addressing requirement
    1 input word
    1 output word
    network frequency limits
    47...63 Hz
    discrete input voltage
    125 V DC
    input voltage limits
    156.2 V including ripple
    voltage state 0 guaranteed
    0...36 V
    voltage state 1 guaranteed
    88...156.2 V
    current state 0 guaranteed
    <= 1.2 mA
    current state 1 guaranteed
    >= 2 mA
    response time
    0.5 or 1.5 ms depending on the filter at state 0 to state 1
    0.5 or 1.5 ms depending on the filter at state 1 to state 0
    discrete output number
    4 1 group of 4
    discrete output type
    Solid state, isolated
    discrete output logic
    Source or sink
    discrete output voltage
    24...125 V
    output voltage limits
    19.2...156.2 V DC typical
    maximum load current
    <= 16 A per module
    <= 4 A per point
    voltage drop
    0.75 V 4 A
    absolute maximum output
    30 A during 500 ms per point
    load capacitance
    <= 0.1 µF 150 V DC
    <= 0.6 µF 24 V DC
    leakage current
    1.2 mA 150 V DC
    protection type
    Internal output protection by 5 A fuse per group
    On input by resistor limited
    On output by transient voltage suppression
    associated fuse rating
    5 A
    isolation between group of I/O channels
    1780 Vrms for 1 minute
    isolation between group and bus
    2500 Vrms for 1 minute
    isolation between channels
    1780 Vrms for 1 minute
    fault indication
    Overcurrent on output
    power dissipation
    0.4 W + (1 x input point on) + (0.75 total output load current)
    local signalling
    1 LED green bus communication is present (Active)
    1 LED red no voltage in output and input (F)
    2 LEDs red fault detected on the output point
    4 LEDs green output is turned on
    4 LEDs red fault detected on the input point
    marking
    CE
    bus current requirement
    350 mA
    product weight
    0.66 lb(US) (0.3 kg)
    Environment
    resistance to electrostatic discharge
    4 kV contact conforming to IEC 801-2
    8 kV on air conforming to IEC 801-2
    resistance to electromagnetic fields
    9.14 V/yd (10 V/m) 80...1000 MHz conforming to IEC 801-3
    ambient air temperature for operation
    32...140 °F (0...60 °C)
    ambient air temperature for storage
    -40...185 °F (-40...85 °C)
    relative humidity
    95 % without condensation
    operating altitude
    <= 16404.2 ft (5000 m)
    protective treatment
    Conformal coating Humiseal 1A33
    standards
    CSA C22.2 No 142
    FM Class 1 Division 2
    UL 508
    product certifications
    CUL
    Ordering and shipping details
    Category
    18155 - QUANTUM I/O & POWER SUPPLIES
    Discount Schedule
    PC21
    GTIN
    00785901620594
    Nbr. of units in pkg.
    1
    Package weight(Lbs)
    2.21
    Returnability
    N
    Country of origin
    CN
    Contractual warranty
    Warranty period
    18 months
  • Documents and Downloads

    Language
    • English
    • French
    Catalog
    Date
    Size
    Add to My Documents
    User guide
    Date
    Size
    Add to My Documents
    Certificate
    Date
    Size
    Add to My Documents
    UL_E486184_NRAQ-NRAQ7_ALL_JUN2018
    Date 8/6/18
    Size 233.4 KB
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Racks for Modules Mounting
    Dimensions of Modules and Racks


    (1)
    2 slots
    (2)
    3 slots
    (3)
    4 slots
    (4)
    6 slots
    (5)
    10 slots
    (6)
    16 slots


  • Connections and Schema

    125 Vdc Discrete Input/High Power Output Module
    Wiring Diagram


    N/C