analog output module Modicon Quantum - 4 O
Show more characteristics >-
Product availabilityNon-Stock - Not normally stocked in distribution facility
-
Characteristics
Main range of product Modicon Quantum automation platformproduct or component type Analogue output moduleComplementary analogue output number 4addressing requirement 4 output wordsanalogue output range +/- 10 V >= 1000 Ohm bipolar voltage+/- 5 V >= 500 Ohm bipolar voltage0...10 V >= 1000 Ohm unipolar voltage0...5 V >= 500 Ohm unipolar voltageanalogue output resolution 12 bitsanalogue output current -10...10 mAsource resistance 0.1 Ohmcable distance between devices 400 mabsolute accuracy error +/- 0.15 % of full scale at 77 °F (25 °C)linearity +/- 1 LSBaccuracy drift according to temperature 0.003 % of full scale/°C unipolar0.004 % of full scale/°C bipolar0.005 % of full scale/°C maximum unipolar0.007 % of full scale/°C maximum bipolarisolation between channels 500 V for 1 minute 47...63 Hz ACisolation between channels and bus 780 V for 1 minute ACupdate time 3 mssetting time 700 µs to +/- 0.1 % of the final value maximumbus current requirement 700 mApower dissipation in W <= 4.5 Wassociated fuse rating 0.063 mA 3 AG fast blow 250 Vmarking CElocal signalling 4 LEDs green channel is turned on4 LEDs red channel fault1 LED green bus communication is present (Active)1 LED red external faultmodule format Standardproduct weight 0.66 lb(US) (0.3 kg)Environment product certifications FM Class 1 Division 2CULstandards UL 508CSA C22.2 No 142resistance to electromagnetic fields 9.14 V/yd (10 V/m) 80...2000 MHz conforming to IEC 801-3ambient air temperature for operation 32...140 °F (0...60 °C)ambient air temperature for storage -40...185 °F (-40...85 °C)relative humidity 95 % without condensationoperating altitude <= 16404.2 ft (5000 m)Ordering and shipping details Category 18155 - QUANTUM I/O & POWER SUPPLIESDiscount Schedule PC21GTIN 00785901792284Nbr. of units in pkg. 1Package weight(Lbs) 1.04Returnability NCountry of origin FROffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile AvailableProduct end of life instructions AvailableCalifornia proposition 65 WARNING: This product can expose you to chemicals including:- - - - - - - Substance 1 Lead and lead compounds which is known to the State of California to cause cancer and birth defects or other reproductive harm.- - - - - - - More information For more information go to www.p65warnings.ca.govContractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
- Spanish
- French
CatalogSizeAdd to My DocumentsModicon™ Quantum™ Ethernet I/O Automation Platform (Version 1.0)Modicon Quantum automation platform - English version 2015/11 (web pdf format) (Version 3.0)Date 6/26/18Size 20 MBUser guideSizeAdd to My DocumentsQuantum with Concept and ProWORX, Hardware Reference Guide (Version 05)Quantum with Unity Pro, Discrete and Analog I/O, Reference Manual (Version 15)CADSizeAdd to My DocumentsAnalog I/O module (Version 1.0)CertificateSizeAdd to My DocumentsCSA _225844_1437816_QUANTUM_FEB2017 (Version 1.0)REACh DeclarationSizeAdd to My DocumentsEU RoHS DeclarationSizeAdd to My Documents -
Technical FAQs
No results found.Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later. -
Dimensions Drawings
Racks for Modules MountingDimensions of Modules and Racks(1)2 slots(2)3 slots(3)4 slots(4)6 slots(5)10 slots(6)16 slots -
Connections and Schema
Analog Output 4-Channel Voltage ModuleWiring DiagramN/CNot ConnectedExternal Wiring RecommendationMaster override is an input connected via an internal relay contact to the output when the module is not active. If connected to an external source, the master override input must be fused by a 1/16 A fuse.
If the master override is not connected to an external source, then it must be connected to common of that channel.The master override relay transition time is typically 2 ms.
The master override inputs must be from an external supply with a source impedance of <200 Ω or tied to system common. These inputs for channels that are in use should not be allowed to float and may be unique for each.