    Powerbus Busway

    Available in 100 A, 225 A and 400 A (600V) ratings

    Plug-in busway has a high-density version with features especially for data center use and 200% neutral or isolated ground bus variations. For data centers, light commercial and retail.

    Powerbus Busway
    • Features


      The Powerbus busway delivers scalable and flexible overhead power distribution with the highest tap-off density on the market.  Simple modularity minimizes unintended downtime, improves safety while optimizing energy efficiency.

      Product Features
       Available in 100 A, 225 A, and 400 A, up to 600 V maximum rating

      Scalable

      • High branch circuit density – up to 20 plug-in unit openings every 10 feet
      • Easy to move, add or change Plug-in Units to meet power needs
      • Up to three branch circuits per Plug-in Unit

      Flexible

      • Uses the same  Plug-in Units across all busway ampacities
      • Add a Plug-In Unit or Power Feed Unit – with metering or without – wherever it’s needed
      • No special tools required to connect busway joints or  Plug-in Units
      • Superior Plug-in Unit design features fast and easy ”hook-swing “ installation  
      • Busway hanger options let designers customize suspension to each application
      • New IT rack-mounting kits reduce installation labor costs and minimize over-rack space interference 

      Benefits

      Efficient

      • Zero footprint saves valuable floor space for revenue-producing machinery, work cells, or IT racks
      • Overhead design maximizes raised floor-cooling air flow while increasing power distribution accessibility
      • Energy-efficient copper bus bars reduce power distribution losses
      • Plug-in Units and Power Feed Units offer optional PowerLogic™ metering  and  communications to monitor energy usage and balance phase loading 

      Safety

      • All busway ratings are listed to UL® 857 Busway Standard For Safety
      • Above-equipment design makes identifying circuits easy while improving cable management of energized Plug-in Units
      • Optional handles on Plug-in Units give technicians more stability when climbing ladders to install units

      Applications

      • Data Centers – power distribution to IT racks
      • Telecommunications – network and switching cabinets
      • Manufacturing and assembly – work cells
      • University and institutions – laboratory stations
      • Distribution warehouses – picking stations