Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

 

Powerbus Busway

Available in 100 A, 225 A and 400 A (600V) ratings

Plug-in busway has a high-density version with features especially for data center use and 200% neutral or isolated ground bus variations. For data centers, light commercial and retail.

Powerbus Busway
  • Features


    The Powerbus busway delivers scalable and flexible overhead power distribution with the highest tap-off density on the market.  Simple modularity minimizes unintended downtime, improves safety while optimizing energy efficiency.

    Product Features
     Available in 100 A, 225 A, and 400 A, up to 600 V maximum rating

    Scalable

    • High branch circuit density – up to 20 plug-in unit openings every 10 feet
    • Easy to move, add or change Plug-in Units to meet power needs
    • Up to three branch circuits per Plug-in Unit

    Flexible

    • Uses the same  Plug-in Units across all busway ampacities
    • Add a Plug-In Unit or Power Feed Unit – with metering or without – wherever it’s needed
    • No special tools required to connect busway joints or  Plug-in Units
    • Superior Plug-in Unit design features fast and easy ”hook-swing “ installation  
    • Busway hanger options let designers customize suspension to each application
    • New IT rack-mounting kits reduce installation labor costs and minimize over-rack space interference 

    Benefits

    Efficient

    • Zero footprint saves valuable floor space for revenue-producing machinery, work cells, or IT racks
    • Overhead design maximizes raised floor-cooling air flow while increasing power distribution accessibility
    • Energy-efficient copper bus bars reduce power distribution losses
    • Plug-in Units and Power Feed Units offer optional PowerLogic™ metering  and  communications to monitor energy usage and balance phase loading 

    Safety

    • All busway ratings are listed to UL® 857 Busway Standard For Safety
    • Above-equipment design makes identifying circuits easy while improving cable management of energized Plug-in Units
    • Optional handles on Plug-in Units give technicians more stability when climbing ladders to install units

    Applications

    • Data Centers – power distribution to IT racks
    • Telecommunications – network and switching cabinets
    • Manufacturing and assembly – work cells
    • University and institutions – laboratory stations
    • Distribution warehouses – picking stations

    Gallery