USA

Schneider Electric USA Website

Welcome to our website.

To view product availability in a specific country, select from the country list below. For Investor Relations, please visit our global site.

Choose another country or region

 

MHL-DC 500 Vdc (450A to 1200A) Circuit Breakers

This is a legacy product

This Product is Obsolete

MHL-DC circuit breakers are designed for 500 Vdc UPS (ungrounded dc) systems ranging 450 A to 1200 A.

Schneider Eletric Square D Picture
MHL-DC 500 Vdc (450A to 1200A) Circuit Breakers
  • Features


    Product Cross-Reference

    Systems that use batteries as a power source, such as an uninterruptible power supply (UPS), require special consideration when specifying overload protection. Square D® 500 Vdc thermal magnetic circuit breakers are designed per UL Supplement SC for use in an ungrounded dc system using an uninterruptible power supply (UPS), with a nominal voltage of 500 Vdc or a maximum (floating) voltage of 600 Vdc.

    Features
    • Voltage Ratings: 500 Vdc nominal, 600 Vdc maximum voltage
    • AIR: 20 kA (450-1000A) ; 25 kA (1200A)
    • UL 489 Supplement SC rated specifically for use on ungrounded dc systems and Uninterruptible Power Supplies (UPS)
    • Industry leading low magnetic trip setting for improved short-circuit protection
      • 450A as low as 1125 dc amperes
      • 500A as low as 1250 dc amperes
      • 600A as low as 1500 dc amperes
      • 700A as low as 1750 dc amperes
      • 800A as low as 2000 dc amperes
      • 900A - 1200A as low as 2500 dc amperes
    • Factory installable accessories available – see catalog
    • Easily accessible adjustable magnetic trip on front face of breaker
    Product Detail:

    MHL3645031DC – 450A, 600V, 3 pole circuit breaker with magnetic trip range from 1125 to 2250 A
    MHL3650032DC – 500A 600V, 3 pole circuit breaker with magnetic trip range from 1250 to 2500 A
    MHL3660033DC – 600A 600V, 3 pole circuit breaker with magnetic trip range from 1500 to 3000 A
    MHL3670035DC – 700A 600V, 3 pole circuit breaker with magnetic trip range from 1750 to 3500 A
    MHL3680036DC – 800A 600V, 3 pole circuit breaker with magnetic trip range from 2000 to 4000 A
    MHL3690039DC – 900A 600V, 3 pole circuit breaker with magnetic trip range from 2500 to 5000 A
    MHL36100040DC – 1000A 600V, 3 pole circuit breaker with magnetic trip range from 2500 to 5000 A
    MHL36120040DC – 1200A 600V, 3 pole circuit breaker with magnetic trip range from 2500 to 5000 A

    Benefits


    Applications

    Crane & Hoist
    Solar Installations
    OEM Commercial
    Metals
    Healthcare Facilities
    Data Centers