    Motor control and protection in accordance with UL 508 standard

    The GV2 manual starter and protector provides manual isolation, manual motor control and thermal overcurrent protection in one compact unit.

    TeSys GV2 Manual Starters and Protectors
    • Features

      Digest-product-info
      The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2ME controls motors with full load currents up to 32 A. The GV2P, high performance manual starter, offers a higher withstand rating and visible trip indication for convenience. The GV2P has an additional UL 508 type E rating as a stand alone self-protected manual combination starter. The UL 508 type E rating requires the addition of line side insulating barrier GV2GH7.



      Benefits

      • UL 508 Listed, CSA Certified, and CE Marked to meet global needs
      • UL Listed for Group Motor Applications when used alone or in combination with TeSys D-Line Contactors in accordance with NEC 430-53
      • Motor control and protection in accordance with standards IEC 947-2 and IEC 947-4-1
      • 10-100 kA UL-listed short circuit current rating depending on application size and voltage
      • 3-pole, 30 hp @ 575 V maximum
      • Designed for motor full load currents up to 32A
      • Compact size 45 mm wide
      • Class 10 ambient compensated Overload relay
      • Single phase sensitivity
      • Magnetic instantaneous short-circuit protection
      • Test trip mechanism
      • The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
      • The addition of a shunt trip enables remote control of tripping
      • Provision for padlocking in the OFF position standard
      • Fingersafe terminals (meets IP20 standards)
      • Available with Screw clamp and screw type terminals for flexibility
      • North American and European terminal markings
         

      Applications

      Industry, infrastructure, building, etc:
      - Motor control and protection, in accordance with standards IEC 947-2 and IEC 947-4-1
      - Easily inserted in any configuration by screw or clip-fixing onto mounting rails