Industrial Circuit Breaker Enclosures
PowerPact (TM) Circuit Breaker Enclosures
- B, H, J, L, M and P Molded Case Circuit Breakers
- L Molded Case Switches and Motor Circuit Protectors
- cULus Listed (See digest for complete listings)
- 30-1200A 600Vac/250Vdc maximum
- PowerPact L enclosure rated 600Vac and 500 Vdc
- NEMA Type 1, 3R, and 12 Enclosures
- NEMA Type 4/4X/5 enclosures
- Stainless Steel Type 304 or Type 316 (250 and 800A)
- Suitable for use as service entrance equipment
- One, Two, Three, and Four Pole circuit breaker configurations
- Short circuit current rating of the enclosures is equal to the interrupter rating , at the supply voltage marked on the circuit breaker installed unless otherwise noted in the digest
- Enclosures will accept 100% rated circuit breakers unless otherwise noted in the digest noted.
Legacy L Frame Thermal-Magnetic and Q4L Circuit Breaker Enclosures:
- UL Listed and CSA Certified
- 125 – 400A 600Vac/250Vdc
- NEMA Type 1, 3R, and 12 Enclosures
- NEMA Type 4/4X/5 enclosures
- Stainless Steel Type 304
- Suitable for use as service entrance equipment
- One, Two, and Three Pole circuit breaker configurations
- Short circuit current rating of the enclosures is equal to the interrupter rating , at the supply voltage marked on the circuit breaker installed unless otherwise noted in the digest
Hazardous Locations:
- Hazardous Locations as Defined by NEC Article 500
- cULus Listed unless otherwise noted in the digest
- 30 – 225 A 600 Vac/250 Vdc
- NEMA/EEMAC Type 7 and 9
- Type 7: Class I, Groups C and/or D, Class II, Groups E, F and/or G, Class III
- Suitable for rainproof applications when the PKDB1 breather and drain kit is installed
- Type 9: Class II, Groups E, F and/or G, Class III
- Short circuit current rating of the enclosures is equal to the interrupter rating , at the supply voltage marked on the circuit breaker installed unless otherwise noted in the digest
- Suitable for use as service entrance equipment
- Enclosures require the use of 75°C copper wire only
Residential Circuit Breaker Enclosures:
- QOM2 Circuit Breaker Enclosures
- UL, NOM/ANSE Listed and CSA Certified
- 100-225A Max. QOM2 circuit breakers
- 22k RMS short circuit current ratings
- Ideal for 100A–225A residential applications with Square D Load Centers, Combination Service Entrance Device Meter-Mains and Circuit Breaker Enclosures
- Provides the flexibility to meet more applications with a single breaker format, which also simplifies inventory stocking
- QOM2 Circuit Breaker Enclosure eliminates the need for Q2L Circuit Breaker Enclosures on single-phase applications
- NEMA Type 1 and Type 3R enclosures
- QO Circuit Breaker Enclosures