Video: How does the standard HOM and the HOM Plug-On Neutral(PoN) Branch circuit breakers install into the HOM and PoN load centers?

Issue:
Differentiating Plug-On/Non-Plug-On Neutral Homeline™ Breakers & Panels

Product line:
HOM branch circuit breakers

Environment:
Installation 

Resolution:
LC = Load Center
PoN = Plug-On Neutral 
HOM = Homeline

The standard, HOM, HOM-CAFI(Non-PoN), HOM-DF(Non-PoN), HOM-GFI(Non-PoN), HOM-EPD(Non-PoN) and HOM-HM branch circuit breakers can be installed in all HOM load centers.
The HOMT tandem breakers can ONLY be installed in the HOM load centers that are designed to accept the HOMT Tandem breakers (See FA101280 to determine if a HOM, LC accepts tandems)
The HOM, PoN Arc Fault, Ground Fault and Dual Function Breakers can ONLY be installed in the HOM, PoN designed Load Centers 

Below is a graphic visual of the Standard HOM and HOMT branch breakers being installed on the interior of a Standard HOM load center. 
This information is available in the below attached instruction bulletin.

​Attached is a video showing the installation of the standard HOM and the Plug-On Neutral Arc fault and/or dual function breakers being installed in the HOM load centers.



NOTE: PLEASE MAKE SURE FOLLOW ALL THE SAFETY INFORMATION PROVIDED AND NEVER WORK ON ENERGIZED EQUIPMENT.