Browse FAQs

How is the code entered to lock or unlock the Altivar 12?

Published date: 15 August 2019

Issue:
I locked my Altivar 12 and can't seem to unlock it?

Product Line:
Altivar Process Drive

Environment:
ALL

Cause:
Programming

Resolution:

Press the dial and scroll to n0n
Enter/Press Dail and scroll down to COD
Ent/Press Dial and scroll to the code you've set (i.e. 1234), press Ent/Dial
Screen goes back to COD
Ent/Dial goes back to your code (i.e. 1234)
Scroll back down until you see OFF press Ent/Dial
Drive is now permanently, or until you set the code again, unlocked.
 

Was this helpful?

What can we do to improve the information ?

Can't find what you are looking for?

Reach out to our customer care team to receive information on technical support, assistance for complaints and more.