Product Detail
LC1D09F7 ContactorContactor , Non-Reversing, 9A, 20A, Screw Clamp$94.00 List Price |
| Certifications | UL Listed (E164862 / NLDX) - CSA Certified (LR43364 3211 04) - IEC Rated (60647-4) - CE Marked - RoHS Compliant |
| Contactor Type | Non-Reversing |
| Inductive Amperes (AC3) | 9A |
| Resistive Amperes (AC1) | 20A |
| Horsepower Rating (1-Phase) | 0.5HP@115Vac - 1HP@230Vac |
| Horsepower Rating (3-Phase) | 2HP@200/230Vac - 5HP@460Vac - 7.5HP@575Vac |
| Marketing Trade Name | TeSys |
| Number of Poles | 3-Pole (3 NO) |
| Maximum Voltage Rating | 600 Vac |
| Mounting Style | 35mm DIN Rail |
| Coil Voltage Code | F7 |
| Coil Consumption Sealed | 7.5 VA |
| Coil Voltage | 110Vac@50/60Hz |
| Coil Consumption Inrush | 70 VA |
| Weight | 0.71 lbs (0.32 kg) |
| Power Wire Size | #10 to #18 AWG |
| Control Terminal Torque | 15 lb-in (1.7 Nm) |
| Power Terminal Torque | 15 lb-in (1.7 Nm) |
| Terminal Type | Screw Clamp |
| Control Wire Size | #10 to #18 AWG |
| Type | TeSys D |
| Category | 22345 - |
| Discount Schedule | I12 |
| GTIN | 00785901206934 |
| Package Quantity | 1 |
| Weight (lbs.) | 0.78 |
| Availability Code | Stock Item: This item is normally stocked in our distribution facility. |
| Returnability | Y |
| Country of Origin | MX |
NOTE: Some items in this list relate to the general product line and may not necessarily apply to part number LC1D09F7. Please check the specific document or download for applicability.
Brochures
Handouts
declarations
drawings
User Manuals
- What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?
- Are replacement contacts avail for D-Line TeSys 9 amp through 80 amp contactors?
- What do the two dots following the TeSys contactor catalog number, like LC1D12.., mean?
- Where are the TeSys 9 amp through 38 amp contactor coil terminals for the control voltage?
- Will an LA4D__ interface module mount directly to a TeSys 9 amp through 38 amp contactor?
- Will an LA4D__ automatic-manual-stop control module mount directly to a TeSys 9 amp through 38 amp contactor?
- How is a TeSys 9 amp through 38 amp contactor removed from DIN rail ?
- What is the contact material composition used in the power contacts of the TeSys D-Line contactors?
- Can the DC control version D-Line TeSys contactor be converted to AC control or vice versa?
- Do we offer an IEC contactor with contacts rated for 600 Vdc?
- What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?
- How do you install an LADN auxiliary contact module on an LC1D TeSys contactor?
- What is the heat dissipated by the LC1D09 contactor?
- What is the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38
- Will an LA4D__ electronic serial timer module mount directly to a TeSys 9 amp through 38 amp contactor?
- It appears to be more difficult to push in the contact carrier on the new TeSys DC-controlled contactors than it was in the old design. Why is that?
- Will a 4-pole LC1D TeSys 9 amp through 38 amp contactor mate up with a 3-pole LRD overload relay?
- What is the altitude derating for a TeSys D-Line contactor?
- What is the replacement coil part number for the LC1D09 through LC1D32 and LC1DT20 through LC1DT40 TeSys contactor?
- What does ``6`` mean in the TeSys catalog number when its position is right before the coil voltage code?
- Is it possible to replace the coils or change the voltage of the coils of the TeSys contactors?