What are the repair parts for an MPR44125, Series M01 Meter Pak Device?

Issue:
Current Design repair parts

Product line:
Meter Pak Metering

Environment:
Repair parts

Cause:
Maintenance

Resolution:
Only the parts listed below are considered field replaceable:

Customer Cover (includes labels) - MP4125C
Circuit Breaker RB Cover (one position) - BCV
Cover Screws - 4020513002K
Meter Socket Cover (ringless type, one position) - MMRC
Pull Box Cover - MP34125PC
Line Phase and Neutral Lugs - MMLK250
Alternate Lug Kits - Refer to Digest
Load Neutral and Service Ground Lugs Assembly - 7329819856 (includes 6 lugs and bus bar the lugs are mounted on) 
Mounting Screws for Load Neutral and Service Ground Lug Assembly:
(1) 2142720163 (mounts assembly at the top to the main neutral bus)
(1) 2149020120 (mounts assembly to the back of the enclosure just below main neutral connection)
(1) 2153217161 (mounts assembly at the bottom to the bracket attached to the enclosure back)

Equipment Ground Lugs Assembly - 7329897053 (includes 4 lugs and mounting bracket) 
Mounting Screws for Equipment Ground lug assembly - 2142217101

Parts Kit (one position, meter socket line side through tenant breaker base) - MM125KIT
Mounting Channel - 7329652001