Technical FAQs

Ask a Question

What are the repair parts for the SC3042M200PF Series M01?

Issue:
Current Design Repair Parts

Product Line:
Combination Service Entrance Devices

Environment:
Repair parts

Cause:
Maintenance

Resolution:

NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable:
Meter Cover Assembly - 4053442852
Meter Cover Mounting Screw - 4020513001K (This kit contains 10 screws, but only one screw is required to secure the cover)
Branch Wiring Gutter Cover (Below Meter Cover) - 4056178101
Branch Wiring Gutter Cover Mounting Screw - 4020513001K (This kit contains 10 screws, but only one screw is required to secure the cover)
Utility Pullbox Cover - 4056181150 (Includes cover latch)
Utility Pullbox Cover Sealing Screw - X1299
Load Center Cover Assembly - EAV67744 (Includes hinges)
Load Center Cover Mounting Screws - 2142217101 (2 required)
Dead Front Interior Trim - EAV67728 (Does NOT include any labels)
Dead Front Interior Trim Mounting Screw - 4020513001K (This kit contains 10 screws, but only two screws are required to secure the interior trim)
Load Center Interior - MTR10002 (Does not include main breaker or ANY of the large branch neutral lugs)
Load Center Interior Mounting Screw - 4020510001 (2 required)
Main Breaker - QOM2200VH (MB comes with mounting screw part #4020511201, that goes through MB casing, through interior into the back of the enclosure)
Main Breaker mounting keps nut - 2342702001 (2 required, attaches the load side of MB to studs in main bus bars)
Meter Base - 4054102503 (Phenolic Base only - does not include line and load phase jaws, see below. If 5th jaw is required order catalog number 5J)
Meter Base Mounting Screw - 2142717200
Meter Socket Jaw - 7329794850 (4 required for complete meter socket, does NOT include blade guide see below)
Meter Jaw Mounting Keps Nut - 2342702001 (one PER meter jaw)
Meter Jaw Blade Guide - 4052761901 (one PER meter jaw)
Meter Jaw with Blade Guide - 7329746450 (4 required for complete meter socket and includes blade guide)
Meter Sealing Ring - 2920910001
Left Line Side Phase Lug - 4025116051
Left Line Side Phase Lugs Mounting Bolt - 2271020242
Left Line Side Phase Lugs Mounting Keps Nut - 2342702001
Right Line Side Phase Lug and Line Side Neutral Lug are not field repairable.
NOTES: 
1) WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE
2) The device comes standard with FIVE large branch neutral lugs; TWO part #LK70AN, One part #4025130250, ONE part #LK100AN and ONE part #LK125AN, IF NEEDING REPLACEMENTS ORDER SEPARATELY.
Was this helpful?
What can we do to improve the information ?