Do ANY of the new Plug-On Neutral Homeline Load Centers come with a ground bar factory included or installed?

Issue:
Product Features

Product Line:
Homeline load center

Environment:
load center accessory

Cause:
Application

Resolution: 
Yes, but ONLY as stated below;
1) The catalog numbers that contain a suffix letter "G" will contain a ground bar factory included, but NOT installed.
For example; the catalog number HOM40820L225PGC will have ground bar factory included. 

2)  The catalog numbers that contain a suffix letter "T" will contain ground bars factory installed.
For example; the catalog number HOM4080M200PTBP will have a ground bar factory installed

NOTE: If the catalog number does NOT contain a suffix letter 'G' or 'T', then a ground bar MUST be purchased separately.
.