How many contact blocks can fit on the ZB5 or ZB4 operators?

Issue:
How many contact blocks can fit on the ZB5 or ZB4 operators?
Product Line:
22mm Push Buttons
Environment:
ZB4/ ZB5 Harmony Push Button
Cause:
Determine the maximum number of contact blocks for an application.                      
Resolution:                                                                 
Nine contacts (3 side by side 3 rows deep) can mount behind standard non-illuminated buttons . 6 behind selector switches, non-illuminated, illuminated push buttons, and non-illuminated push pull and turn to release mushroom buttons.  4 behind illuminated push pull mushroom buttons,  illuminated selector switches and non-illuminated trigger action mushroom buttons.   3 behind non-illuminated push on push off buttons, and 2 behind illuminated push on push off buttons.

The contact blocks enable variable composition of body sub-assemblies and can be stacked to 3 rows, either: 3 rows of 3 single
contacts or 1 row of 3 double contacts + 1 row of 3 single contacts (double contact blocks occupy 2 rows).