What are the repair parts for a RC816D200CH Series 002?

NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable:
Issue:
Repair parts

Product Line:
CSED

Environment:
Repair parts

Cause:
Maintenance

Resolution:
Rainproof Cap - 40561-158-03 (This is the top cap that covers the top endwall of the device)
Rainproof Cap Mounting Screws - (2) 21427-17161
Meter Cover Assembly - 4056143052 (Includes latch)
Load Center Cover Assembly - 4056128052 (Includes hinges)
Load Center Cover Mounting Rivet - (4) 2430315290
Dead Front Interior Trim - 4056114503
Dead Front Interior Trim Mounting Screw - 4020513001K (This kit contains 10 screws, but only one is required to mount the interior trim)
Load Center Interior - 4056133352 (Does not include main breaker. Does not include secondary main breaker mounting base. Includes feed-thru lugs.)
Load Center Interior Mounting Screws - (7) 2153217161
Main Breaker - HOM2200
Main Breaker Retaining Hardware - 4056132701 (hold down strap that stradles across the main breaker), 4056152501 (clamp), 4056152601 (spacer) and 2159417721 (screw). The clamp, spacer and screw are used on the line side of the main breaker.
Feed-Thru Phase Lug Assembly (Left) - 4056133252
Feed-Thru Phase Lug Assembly (Right) - 4056133152
Feed-Thru Phase Lug Assemblies Mounting Keps Nut - (2) 2342702000
Feed-Thru Neutral/Ground Lug - 4025114550 (double barrel lug)
Feed-Thru Neutral/Ground Lug Mounting Nut - 2342702200
Secondary Main Breaker Base Assembly- 4055841752
Secondary Main Breaker Base Assembly Mounting Screws - 2153217161
Meter Base Assembly - 4056149752 (Includes load side lugs, meter jaws and horn bypasses. Does not include load side meter jaw blade guides)
Meter Jaw - (2) 4052706950 (OBSOLETE - REPLACED BY 7329794850) (Load side meter jaws are included in the Meter Base Assembly)
Meter Jaw Mounting Keps Nut - (2) 2342702001 (Load side meter jaw mounting keps nuts are included in the Meter Base Assembly)
Meter Jaw Blade Guide - (4) 4052761901
Fifth Jaw Assembly - 4052729550
Fifth Jaw Assembly Mounting Screw - 2153217161
Line Side Horn Bypass - (2) 4056150901 (Line side horn bypasses are included in the Meter Base Assembly)
Line Side Phase Lugs - (2) 4025116051
Line Side Phase Lugs Mounting Carriage Bolts - (2) 2271020242
Line Side Phase Lugs Mounting Keps Nuts - (2) 2342702000
Line Side Neutral Lugs - (2) 4025116051
Line Side Neutral Lugs Mounting Keps Nuts - (2) 2342702000
Service Ground Lug - 4025102451
Service Ground Lug Mounting Keps Nut - 2342702001
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE.